Showing 1 to 14 of 14 for “"4MHz"”.
-
An investigation on the use of micro-ultrasonic-transducers for anticancer drugs cytotoxicity enhancement
… values were 86% for lMHz and 71 % for 4MHz ultrasound. Overall, the measured characteristics of the selected transducers were in good agreement with theoretical values. The output ultrasonic powers were also found to be consistent over four months. Tone-burst ultrasound (32 Watt/cm2, …
-
Micromechanical resonator based bandpass sigma-delta modulator
… The test results have shown that when sampled at 4MHz the peak SNR in 200-kHz signal bandwidth is measured to be 22dB while the Matlab simulated value is 25dB. The modulator is also functional at the sampling frequency of 32MHz.
-
A Miniaturized Delay-Line Discriminator
… measurement range of over 2 GHz with better than 4MHz RMS accuracy. Additional processing of the discriminators' outputs is required to further improve this accuracy. Measurements of pulses with phase and frequency modulation present have demonstrated the potential for the identifification of …
-
Design And Analysis Of Reconfigurable Sensing Antennas For Wireless Sensing Applications
… results show that these two designs provide 4mhz/10â°c and 8mhz/10â°c frequency shift with temperature, respectively. Their realized gain is -3.2db with 4.33%
-
Forming Screen Effect on Ultrasonic Beam Field
… transducers: a 2 MHz 10 mm, 4 MHz 5 mm, 4MHz 8 mm focused, and 8 MHz 5 mm. The ultrasonic signals were then analyzed in order to determine the ultrasonic beam echo amplitude and shape. These tests were performed with and without various paper forming screens placed between the ultrasonic …
-
Scalp spreading depression
… and extended the clinical EEG lower band to 4mHz. Our device successfully recorded SD waves from the surface scalp of epileptic patient during clinical EEG monitoring for the first time, marking a significant breakthrough [73]. We examined DC and AC EEG in 18 epileptic patients using our …
-
Highly Integrated Dc-dc Converters
… that the operating frequency could be as high as 4MHz and the efficiency could be improved by more than 10% compared to that when a hyper fast diode rectifier is used. Based on a new current-source gate driver scheme, an integrated gate driver for buck converter is also developed in this work by …
-
MOSFET Current Source Gate Drivers, Switching Loss Modeling and Frequency Dithering Control for MHz Switching Frequency DC-DC Converters
… converters that can operate above 500kHz up to 4MHz. In the near future, most DC-DC switching converters for communications and computers will operate at switching frequencies of 1-10MHz in order to achieve greater power density and improved transient response. To meet the next generation …
-
Multi-modal Fully-wireless Implantable SoCs for Interfacing with the Nervous System
… for biochemical microsensors. The SoC utilizes a 4MHz safety-optimized inductive-powering link for maximum power transfer under a given specific-absorption-rate constraint. The second system is an active probe and microstimulator SoC for interfacing with peripheral nerves. It performs 64-channel …
-
Implementation of Real-Time Software Receiver for Gps or Glonass L1 Signals
… Analog Signal Generator configured to output a 64MHz signal has been used as an external input clock to the USRP. This oscillator has a stated frequency error of 1 ppm/yr, has decent short-term frequency stability, and has a reasonably low phase noise at 64MHz. The outputs of the USRP board are 8 …
-
High Frequency, High Efficiency Two-Stage Approach for Future Microprocessors
… loss can push the switching frequency up to 4MHz while maintaining good efficiency. Such a high frequency makes the high bandwidth design (650kHz) feasible. Hence, the output capacitance can be significantly reduced to save cost and real estate. The two-stage concept is also effective in …
-
Ultrasound Stimulation of a Piezoelectric Composite with Compliant Layers on Power Output for Bone Healing in Spinal Fusion Applications
… loading orientations. The CLACS were subject to 4MHz ultrasound waves (1 W) in a Gaussian shape pattern with a V4 vector 128 PZT element array probe (Mountain View, CA). Voltage measurements before rectification (alternating current - AC) and after rectification (direct current - DC) were …
-
Integrated Wideband Self-Interference Cancellation Techniques for FDD and Full-Duplex Wireless Communication
… measured self-interference cancellation over 4MHz bandwidth, and an integrated power amplifier (PA) which suppresses the 3rd and 5th harmonics by 30dB and 15dB, respectively. The PA delivers a maximum output power of +14dBm with a drain efficiency of 33%. The self-interference cancellation …
-
Vstupní díl softwarového přijímače pro pásma VKV a UKV
První část této práce obsahuje podrobnější rozbor nejzákladnějších parametrů VKV/UKV přijímačů. Stručně jsou vymezeny nejdůležitější pojmy jako, šumové číslo, citlivost či zisk. Následující kapitola pak přímo určuje a snaží se o přibližný výpočet a analýzu nejdůležitějších parametrů konkrétního …