Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 57 for “"511 keV"”.
-
The Origin of the 511 keV Positron Annihilation Emission Morphology
The 511 keV positron annhilation emission from the Galactic bulge has yet to solely be attributed to any astrophysical source of positrons. The 511 keV line, characteristic of electron-positron annihilation, was discovered in 1970 by Johnson and Haymes [1973] almost 40 years ago. Most recently the …
-
Modeling the Galactic 511 keV Positron Annihilation Emission, Production, and Propagation
The Galactic 511 keV positron annihilation emission has a strong bulge component to the emission and a weak disk component. The bulge emission is about 1.4 -- 6 times as the disk emission. The bulge emission is defined to be a diffuse emission centered at the Galactic center and extends to about a …
-
Information Field Theory with INTEGRAL/SPI data
… Emission der galaktischen Positronenannihilation 511 keV zu generieren. Der dabei entwickelte Algorithmus basiert auf der Informationsfeldtheorie (IFT). IFT erlaubt neben der alleinigen Analyse der Daten auch das Nutzen von A-priori-Information über das Signal in Form einer …
-
Experimental Determination of Shielding Requirements for PET Medical Facilities
… imaging facility, because of the high energy (511 keV) of electron-positron annihilation photons. Since radiation emitted from patients administered PET radiopharmaceuticals includes lower-energy scattered photons, a given thickness of lead attenuates more of the radiation than it would for a …
-
Gamma-ray emission from Galactic millisecond pulsars: Implications for dark matter indirect detection
… Finally, we study the spatial morphology of the 511 keV signal toward the Galactic center using data from INTEGRAL/SPI. We confirm that the 511 keV signal also traces the old stellar population in the Galactic bulge, which is similar to the Fermi GeV excess. Using a 3D smoothing kernel, we find …
-
Optimizing Compton camera performance
… (FWHM) image resolution at 140.5 keV and 511 keV respectively. On the other hand, detector spatial resolution which accounts for the least image degradation at 140.5 keV is found to be the dominant degrading factor at 511 keV, suggesting that the absorber parameters play major …
-
Προσομοίωση γεγονότων τριπλής σύμπτωσης σε σύστημα τομογραφίας εκπομπής ποζιτρονίων
… παραγωγή δύο αντιδιαμετρικών φωτονίων ενέργειας 511 keV, τα οποία απορροφώνται από ανιχνευτές που σχηματίζουν μια γεωμετρία δακτυλίου. Η τελική εικόνα παρέχει τιμή χωρικής διακριτικής ανάλυσης περίπου 4-5 χιλιοστά, μία από τις χαμηλότερες στο φάσμα των διαγνωστικών συστημάτων. Με τη συμβολή του …
-
An Integrated Study of Instrument Performance and Scientific Yield: Evaluation of the GRAPE Design
… a targeted energy band of \SIrange{50}{500}{keV} to cover the peak energy output (E$_{pk}$) of observed GRB spectra. This work establishes the instrument's scientific readiness through two principal contributions. First, the instrument's fundamental low-energy response was characterized …
-
Development of a cost-effective detector for an MRI compatible brainPET
… and timing pick-off detector setup to capture 511 keV annihilation photon pairs emitted by a 22Na source, using the PETsys TOFPET2 ASIC for signal readout and digitization. The detector block is a Dual-Layer Offset (DLO) array of 2.4 mm pitch Lutetium-Yttrium Oxyorthosilicate (LYSO) …
-
ModPET: Novel Applications of Scintillation Cameras to Preclinical PET
… accomplished with collimated beams of 511-keV photons and a new iterative mean-detector-response-function processing routine. Intrinsic lateral spatial resolution for 511-keV photons was found to be approximately 1.6 mm in each direction. Lists of coincidence pairs are found by …
-
Measurements and Simulations of the Gamma-ray Background with ComPair and Multi-Messenger Analyses of Pulsar Systems
… a range of companion types and re-emitting as 511 keV γ-rays, where the orbital dependence of the 511 keV γ-rays is directly related to companion composition. The second study searches for gravitational waves emitted by pulsars in 2 parts. The first part considers emission following the Vela …
-
Observing a light dark matter beam with neutrino experiments
… motivated by an explanation of the galactic 511 keV line are strongly constrained.
-
Characterization of silicon photomultiplier readout designs for use in positron emission tomography systems
… custom made. The detectors are tested for their 511 keV photon energy and timing resolution, as well as their ability to measure light from small scintillator crystals. The two custom made detectors had smaller active area, but outperformed the commercial detector in energy resolution. The …
-
FPGA-Based System for Radiation Energy Histogram Computation using Time-Over-Threshold
… demonstrated clearly resolved photopeaks at 113 keV, 208 keV, and 511 keV. The PODD’s compact form factor and wireless operation enable accessible point-of-care dosimetry for personalized radiopharmaceutical therapy.
-
Attenuation Correction in Positron Tomography
… ¹³⁷Cs emits a monoenergetic gamma ray at 662 keV, and emission data are acquired by detecting annihilation photons of energy 511 keV, a simple extrapolation method is developed to extrapolate the attenuation coefficients measured at 662 keV to 511 keV. To eliminate scatter contamination in the …
-
The production of Be(7), C(11), N(13), or O(15) from carbon, nitrogen and oxygen by 87-mev electrons.
… fragments were detected by observing the 477-KeV gamma ray from the daughter nucleus Li(7) . The other disintegration fragments were detected by the annihilation of the emitted positrons which produced 511-KeV photons. A copper radiator was introduced in one-half of the bombardments of each …
-
The production of Be(7) and C(11) from carbon, nitrogen, and oxygen by 75-MeV electrons
… detecting their decay activity, Be(7) by the 477-Kev gamma ray from its daughter nucleus and C(11) by the 511-Kev photons from the annihilation of its emitted positron. Electron and photon effects were separated by interposing an additional radiator for one bombardment of a given type of target, …
-
The mineral-PET rock sorter : a study of the ( y,n) activation process
… in two back-to-bad<: gamma photons, each at 511 keV energy, which is then detected by the matrix of position sensitive fast timing BGO (bismuth germanate- Bi₁₂Ge₄O₄) detectors. This study investigate the activation process where gamma photons in the energy range of around 25 lVIe V are …
-
Avaliação da eficácia do avental equivalente a 0,5 mm de chumbo em tomografia por emissão de Pósitrons através de simulações Monte Carlo
… de saúde estão expostos a fótons de 511 keV, resultante do processo de aniquilação pósitron-elétron. Este valor é cerca de quatro vezes superior à energia média dos fótons com 140 keV, normalmente emitida em ambiente envolvendo Tomografia por Emissão de Fóton Único (SPECT). Apesar …
Page 1 of 3