Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 274 for “"A-scan"”.

  1. A scan line algorithm for displaying curved surfaces

    … element. Monotonic surfaces are processed by scan line order to minimize the time for removing hidden surfaces and to enhance the ray-tracing process. The resulting algorithm renders real istic pictures with very high speed.</p>

    ut-knoxville Repository record for A scan line algorithm for displaying curved surfaces (opens in a new tab)

  2. Comparison of the Lenstar Optical Biometer and A-scan Ultrasonography to Measure Ocular Components

    … optical biometer to those measured with A-scan ultrasound in the tree shrew model of refractive development and induced myopia. A-scan ultrasonographic measures (A-scan) were taken with a 15 MHz focused pulser/receiver and compared with measures made with the Lenstar LS900 optical biometer …

    uab Repository record for Comparison of the Lenstar Optical Biometer and A-scan Ultrasonography to Measure Ocular Components (opens in a new tab)

  3. Development and comparison of algorithms for generating a scan sequence for a random access scanner

    … data acquisition systems incorporate high speed scanners to convert analog signals into digital format for further processing. Some systems multiplex many channels into a single scanner. A random access scanner whose scan sequence is specified by a table in random access memory will permit …

    ut-knoxville Repository record for Development and comparison of algorithms for generating a scan sequence for a random access scanner (opens in a new tab)

  4. A Scan of the Cross Section σ(p̅p → Λ̅Σ° + c.c.) from Threshold to 2.5 MeV Excess Energy

    Submitted by Jesse Garrison (jagarris@illinois.edu) on 2012-01-13T19:16:26Z No. of bitstreams: 1 1998_bunker.pdf: 6728301 bytes, checksum: 238b9efb537e9f40a26bb1698f8fef3c (MD5)

    uiuc Repository record for A Scan of the Cross Section σ(p̅p → Λ̅Σ° + c.c.) from Threshold to 2.5 MeV Excess Energy (opens in a new tab)

  5. A scan of community economic development organizations, rural communities and First Nations in Manitoba and their participation in the New Economy

    The growth of the New Economy has the potential to positively benefit community economic development (CED) organizations, rural communities and First Nations in Manitoba. Organizations and communities have not necessarily profited equally from this knowledge-based economy. This study sought to …

    manitoba Repository record for A scan of community economic development organizations, rural communities and First Nations in Manitoba and their participation in the New Economy (opens in a new tab)

  6. A Scan of the Cross Section of the Reaction (Antiproton + Proton Going to Antilambda + Sigma-0 and Charge Conjugate) From Threshold to 2.5 MeV Excess Energy

    The total cross section of the reaction pp&rarr;LS0+c. c. at ten momentum values within 2.5 MeV of threshold was measured using the Low Energy Antiproton Ring (LEAR) at CERN. The cross section was normalized against the similar reaction pp&rarr;LL and a novel background estimation using …

    uiuc Repository record for A Scan of the Cross Section of the Reaction (Antiproton + Proton Going to Antilambda + Sigma-0 and Charge Conjugate) From Threshold to 2.5 MeV Excess Energy (opens in a new tab)

  7. Mathematical modelling of optical coherence tomography and solutions of the inverse scattering problem

    … biological tissue cross-sections and produce A-scans. A-scans contain numerous peaks that are associated with layer interfaces in a given sample. Trained medical staff may be able to make a qualitative interpretation of an OCT A-scan. However, this interpretation is not always reliable in terms …

    edithcowan Repository record for Mathematical modelling of optical coherence tomography and solutions of the inverse scattering problem (opens in a new tab)

  8. Position based laser power (PBLP) control for selective laser sintering (SLS)

    … (SLS) machine. Current commercial laser scanning systems do not allow for variable laser power control along the length of a scan line. As found in previous work, varying the power across a scan line is important to achieving a uniform post-sintering temperature in the presence of a …

    texas Repository record for Position based laser power (PBLP) control for selective laser sintering (SLS) (opens in a new tab)

  9. Detecting a Heterogenous Sample of Pigmented Melanoma Cell Lines Using Photoacoustic Flow Cytometry

    … until a mass can be visually detected on a scan, such as a PET, CT, or MRI. Once visible on a scan, the cancer is too progressive for successful treatment. To avoid this, we investigated how a blood sample can be used to negate a missed diagnosis, by using photoacoustic flow cytometry to …

    duquesne Repository record for Detecting a Heterogenous Sample of Pigmented Melanoma Cell Lines Using Photoacoustic Flow Cytometry (opens in a new tab)

  10. Characterising the effect of a novel optical delay line and light sources on the resolvability of time domain optical coherence tomography

    … auto-correlograms, and OCT cross-correlograms (A-scan) (produced using many different OCT light sources), has necessitated the extrinsic-evolution of an OCT simulation model, presented in this thesis. This research indicated that empirical resolution in vivo is also strongly dependent on the …

    edithcowan Repository record for Characterising the effect of a novel optical delay line and light sources on the resolvability of time domain optical coherence tomography (opens in a new tab)

  11. Real time defect detection in welds by ultrasonic means

    … technique and statistical analysis based on B-scan data have proved their feasibility to increase 'signal to noise ratio' effectively and to judge or assess weld defects. The hardware and the software for the system is explained in this work. By using this system, real-time 'A-scan' signals on …

    brunel Repository record for Real time defect detection in welds by ultrasonic means (opens in a new tab)

  12. Programmed Temperature Electrospray Ionization (ptESI) for Thermal Cycling of Proteins

    … both unfolding and refolding. ptESI uses fast scan rates, allowing for short experiment times, and results in data dense experiments. As mass spectra are acquired continuously while temperature is scanned. Both ubiquitin and lysozyme exhibited highly reversible unfolding and refolding at …

    washington Repository record for Programmed Temperature Electrospray Ionization (ptESI) for Thermal Cycling of Proteins (opens in a new tab)

  13. Prediction of Accommodative Optical Response in Young and Pre-Presbiopic Human Eyes Using Ultrasound Biomicroscopy

    … young human subjects using a 35 MHz UBM and an A-scan ultrasound. 2) Static AOR to the same stimulus demand were measured with GS and PR in the same group of young subjects. AOR was predicted from UBM measured biometry parameters using linear regression, 95% confidence intervals and 95% prediction …

    houston Repository record for Prediction of Accommodative Optical Response in Young and Pre-Presbiopic Human Eyes Using Ultrasound Biomicroscopy (opens in a new tab)

  14. Generation of high resolution tomographic images for NDT applications

    … be made. However, if the quality of the raw A-scan data is not sufficiently high then the data will be filtered using Maximum Likelihood Deconvolution (MLD). The aim of this blind deconvolution method is to improve the time resolution and Signal to Noise Ratio of the A-scan data with only …

    strathclyde Repository record for Generation of high resolution tomographic images for NDT applications (opens in a new tab)

  15. Non-destructive Ultrasound Thickness Characterization of Parts Additively Manufactured by Fused Filament Fabrication

    … to corrosive/abrasive chemicals or slurries. A-scan mode or time-amplitude scan ultrasound testing provides a one-dimensional representation of material interfaces. This method uses sound waves and converts them into spikes that correspond with material interfaces, and therefore is commonly used …

    ottawa-retro Repository record for Non-destructive Ultrasound Thickness Characterization of Parts Additively Manufactured by Fused Filament Fabrication (opens in a new tab)

Page 1 of 14