Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 34 for “"A-scans"”

  1. Mathematical modelling of optical coherence tomography and solutions of the inverse scattering problem

    … biological tissue cross-sections and produce A-scans. A-scans contain numerous peaks that are associated with layer interfaces in a given sample. Trained medical staff may be able to make a qualitative interpretation of an OCT A-scan. However, this interpretation is not always reliable in terms …

    edithcowan Repository record for Mathematical modelling of optical coherence tomography and solutions of the inverse scattering problem (opens in a new tab)

  2. A Tunable Extended Depth of Focus Microscope Through Beam Shape Modulation into an Axicon Lens

    … high resolution depth profiles, or Axial scans (A-scans), comparable to Optical Coherence Tomography (OCT). Although OCT imaging systems can capture large depth A-scans to buildup high-resolution volumetric images, the information detected by these systems is entirely dependent on the …

    tamu Repository record for A Tunable Extended Depth of Focus Microscope Through Beam Shape Modulation into an Axicon Lens (opens in a new tab)

  3. BREAST TISSUE CLASSIFICATION USING STATISTICAL PATTERN RECOGNITION ON BACKSCATTERED ULTRASOUND.

    … pattern recognition to classify ultrasound A-scans, before any processing other than amplification occurs. A U. I. Octoson was used to collect data from normal, benign, and malignant, in vivo breast tissues. Features based on textural or frequency content of received sound were computed from …

    arizona-thes Repository record for BREAST TISSUE CLASSIFICATION USING STATISTICAL PATTERN RECOGNITION ON BACKSCATTERED ULTRASOUND. (opens in a new tab)

  4. Ultrasonic stochastic localization of hidden discontinuities in composites using multimodal probability beliefs

    … two-dimensions based on statistical data of A-Scans and C-Scans. Multiple experiments have been performed on carbon fiber reinforced plastics including artificial delaminations and porosity at different depths in the thickness of material. A probabilistic approach, which precisely localizes …

    unsw Repository record for Ultrasonic stochastic localization of hidden discontinuities in composites using multimodal probability beliefs (opens in a new tab)

  5. Análise de sinais ultrassónicos na caraterização de catarata ocular

    … this study, using ultrasonic signals (A-scans), the aim is to locate the maininterfaces of the human eye (anterior and posterior lens) and detect the stiffnessassociated with each type of cataract (incipient cataract or mature cataract), if thisexists.The propagation of ultrasonic signals …

    coimbro Repository record for Análise de sinais ultrassónicos na caraterização de catarata ocular (opens in a new tab)

  6. Development of multi-modal neural acquisition modality including optical coherence tomography and neuroelectrophysiology : towards a quantitative multi-modal rat brain atlas

    … into grayscale images by horizontally aligning A-scans from the same trajectory at different depths. The reconstructed images were able to display brain morphology along the fiber insertion trajectory. For scans of typical white matter, the signals showed a higher intensity of backscattered light …

    freiburg-diss Repository record for Development of multi-modal neural acquisition modality including optical coherence tomography and neuroelectrophysiology : towards a quantitative multi-modal rat brain atlas (opens in a new tab)

  7. Multistage adaptive noise cancellation and multi-dimensional signal processing for ultrasonic nondestructive evaluation

    … techniques rely on differences in individual A-scans to classify the signals. This thesis investigates the need for investigating signal features that incorporate the effects of beam spread and echo dynamics. Such effects call for data interpretation schemes that include a neighborhood of …

    iastate Repository record for Multistage adaptive noise cancellation and multi-dimensional signal processing for ultrasonic nondestructive evaluation (opens in a new tab)

  8. The spatial cross-correlation coefficient as an ultrasonic detection statistic

    … coefficients are calculated between A-scans digitized at adjacent measurement positions and can be formed into images that are similar to C-scan images. We also describe an approach for generating simulated acoustic noise with a spatial correlation coefficient distribution and maximum …

    missouri Repository record for The spatial cross-correlation coefficient as an ultrasonic detection statistic (opens in a new tab)

  9. Development of Optical Technologies for Comprehensive Screening of Cervical Epithelial Health

    … mLCI was adapted for collecting A-scans over the cervical epithelium. An mLCI cervical probe was designed and a clinical study was conducted to image 50 patients with the new device. Linear discriminant analysis was performed on the mLCI data to automatically classify the cervical …

    duke Repository record for Development of Optical Technologies for Comprehensive Screening of Cervical Epithelial Health (opens in a new tab)

  10. Ultrasonic NDE signal classification on steam generator tubes

    … used to get multi-resolution representation of A-scans. Features from different decomposition levels were extracted. Image processing and binary morphology were also used to get features from 2-D images of defects. Useful features such as image area and image moments were extracted. An oblique …

    iastate Repository record for Ultrasonic NDE signal classification on steam generator tubes (opens in a new tab)

  11. Ultrasonic signal processing and classification using principal component analysis

    … techniques rely on differences in individual A-scans to classify the signals. Ultrasonic NDE classification is performed using PCA derived features. These features may be used to quantify the variance in NDE signals and determine how the ultrasonic signals vary based upon the class. …

    iastate Repository record for Ultrasonic signal processing and classification using principal component analysis (opens in a new tab)

  12. Untersuchung retinaler Perfusionsdichten mittels OCT-Angiographie beim Primären Offenwinkelglaukom vs. Pseudoexfoliationsglaukom

    … Eine zusätzliche graphische Evaluation von OCT-A-Scans kann möglicherweise die Vergleichbarkeit bei quantitativen Gefäßanalysen optimieren. Weitere Studien sind erforderlich, die die vaskuläre Pathogenese beim Glaukom und das methodische Vorgehen der quantitativen Gefäßanalyse mit der OCT-A weiter …

    fu-berlin Repository record for Untersuchung retinaler Perfusionsdichten mittels OCT-Angiographie beim Primären Offenwinkelglaukom vs. Pseudoexfoliationsglaukom (opens in a new tab)

  13. Digital signal and image processing techniques for ultrasonic non-destructive evaluation

    … performance over a set of 64 sequential A-scans. These results show that the new approaches can detect all the test targets, with near zero false alarms, representing a considerable improvement over the performance of existing methods. The results of array and image processing are presented …

    city-london Repository record for Digital signal and image processing techniques for ultrasonic non-destructive evaluation (opens in a new tab)

  14. Application au contrôle non destructif ultrasonore d'un algorithme de déconvolution utilisant des réseaux de neurones convolutifs

    … méthode de traitement des signaux ultrasonores A-Scans, imitant la déconvolution mais utilisant des techniques d’apprentissage machine. La déconvolution permet d’obtenir de très bons résultats en théorie mais perd beaucoup en efficacité en pratique. L’objectif est double : permettre une inspection …

    ets-quebec

  15. Analog Signal Processing for Optical Coherence Imaging Systems

    … This OCT system can acquire up to 1600 A-scans per second. The measured dynamic range is 106dB at 200A-scan per second. This OCT signal processing electronics includes an off-the-shelf filter box with a Log amp circuit implemented on a PCB board.The second ASP solution was developed for an …

    arizona-thes Repository record for Analog Signal Processing for Optical Coherence Imaging Systems (opens in a new tab)

  16. Dynamic Biomechanical Characteristics of the Optic Nerve Head by OCT Imaging

    … information. As a result, discontinuities of A-scans and the tilt of the central axis were reduced. To determine if IOP-induced strains are a metric of acute morphological changes in various anatomical ONH tissues, we assessed the repeatability of in vivo strain measurements. Strain variability …

    uab Repository record for Dynamic Biomechanical Characteristics of the Optic Nerve Head by OCT Imaging (opens in a new tab)

  17. Nondestructive Evaluation of Structural Defects in Concrete Slabs

    … the dense meshing. The amplitude data from GPR A-scans (amplitude vs depth) were used to calculate the depth of a defect. Statistical measures exhibit a high degree of agreement between the depth measured by GPR and the actual depth of a defect. The IE method uses elastic waves to propagate …

    gsu Repository record for Nondestructive Evaluation of Structural Defects in Concrete Slabs (opens in a new tab)

Page 1 of 2