Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 67 for “"AAPM"”

  1. Effectiveness of Advanced and Authenticated Packet Marking Scheme for Trace back of Denial of Service Attacks

    Advanced and Authenticated Packet Marking (AAPM) scheme is one of the proposed packet marking schemes for the traceback of Denial of Service (DoS) attacks. AAPM uses hash functions to reduce the storage space requirement for encoding of router information in the IP header. In this paper we take the …

    bridgeport Repository record for Effectiveness of Advanced and Authenticated Packet Marking Scheme for Trace back of Denial of Service Attacks (opens in a new tab)

  2. REEVALUATION OF THE AAPM TG-43 BRACHYTHERAPY DOSIMETRY PARAMETERS FOR AN <sup>125</sup>I SEED, AND THE INFLUENCE OF EYE PLAQUE DESIGN ON DOSE DISTRIBUTIONS AND DOSE-VOLUME HISTOGRAMS

    The TG-43 dosimetry parameters of the AdvantageTM 125I model IAI-125A brachytherapy seed were studied. An investigation using modern MCNP radiation transport code with updated cross-section libraries was performed. Twelve different simulation conditions were studied for a single seed by varying the …

    uky-thes Repository record for REEVALUATION OF THE AAPM TG-43 BRACHYTHERAPY DOSIMETRY PARAMETERS FOR AN <sup>125</sup>I SEED, AND THE INFLUENCE OF EYE PLAQUE DESIGN ON DOSE DISTRIBUTIONS AND DOSE-VOLUME HISTOGRAMS (opens in a new tab)

  3. Application of ab initio calculations to collagen and brome mosaic virus

    … the method we call the Amino-Acid Based Method (AAPM) of OLCAO. In brief, the AAPM calculates electronic, self-consistent fi eld (scf) potentials for individual amino-acids with their neighboring amino-acids included as a boundary condition. This allows the costly scf part of the calculation to …

    umkc Repository record for Application of ab initio calculations to collagen and brome mosaic virus (opens in a new tab)

  4. ANALYSIS OF ADJUSTED AND ADVANCED PACKET MARKING SCHEMES FOR TRACEBACK OF DENIAL OF SERVICE ATTACKS

    … Advanced and Authenticated Packet Marking (AAPM) is another proposed marking scheme traceback of DoS attacks. AAPM uses hash functions to reduce the storage space requirement for encoding of the router IP address into the marking field of the IP packets. Here, a study is presented from the …

    ohiolink Repository record for ANALYSIS OF ADJUSTED AND ADVANCED PACKET MARKING SCHEMES FOR TRACEBACK OF DENIAL OF SERVICE ATTACKS (opens in a new tab)

  5. Διασφάλιση Ποιότητας στη Λειτουργική Μαγνητική Απεικόνιση - fMRI

    … συστήματος, σύμφωνα με τα πρωτόκολλα της AAPM και του FBIRN, μακροπρόθεσμα και βραχυπρόθεσμα, καθώς επίσης και την συμπεριφορά του με χρήση κάποιων παραμέτρων και εξαρτημάτων, όπως τα συνήθη φώτα, τον δυναμικό φωτισμό μαζί με τον βιντεοπροβολέα του συστήματος και τη χρήση του …

    athens Repository record for Διασφάλιση Ποιότητας στη Λειτουργική Μαγνητική Απεικόνιση - fMRI (opens in a new tab)

  6. Quality Assurance Procedures Implementation for Varian TrueBeam

    … ensure that patients receive quality care. The AAPM (American Association of Physicists in Medicine (AAPM) Task Group (TG) 142 recommends daily, monthly, and annual QA of the linear accelerators with predesignated tolerances for non-IMRT, IMRT, and SRS/SBRT treatment techniques. In the Oncology …

    unlv Repository record for Quality Assurance Procedures Implementation for Varian TrueBeam (opens in a new tab)

  7. 142pr glass seeds for the brachytherapy of prostate cancer

    … American Association of Physicists in Medicine (AAPM) TG-43/60. The Monte Carlo calculation results were compared with those from a dose point kernel code. The dose profiles agree well with each other. The gamma dose of 142Pr was evaluated. The gamma dose is 0.3 Gy at 1.0 cm with initial activity …

    tamu Repository record for 142pr glass seeds for the brachytherapy of prostate cancer (opens in a new tab)

  8. Optimization of Permanent Breast Seed Implant Dosimetry Incorporating Tissue Heterogeneity

    … around brachytherapy sources is based on the AAPM TG43 formalism, which generates the dose in homogeneous water medium. Recently, AAPM task group no. 186 (TG186) emphasized the importance of accounting for heterogeneities. In this work we introduce an analytical dose calculation algorithm in …

    toronto-retro Repository record for Optimization of Permanent Breast Seed Implant Dosimetry Incorporating Tissue Heterogeneity (opens in a new tab)

  9. Avaliação dos equipamentos de ultrassonografia da região metropolitana do Recife

    … pela Associação Americana de Física Médica (AAPM), uma vez que não há no país um protocolo para estes testes. Neste trabalho foi efetuado o levantamento dos dados dos equipamentos com relação à idade e tipo de transdutor, bem como condições e causas de manutenção.Foram também avaliados os …

    brazil-ufpe Repository record for Avaliação dos equipamentos de ultrassonografia da região metropolitana do Recife (opens in a new tab)

  10. The Effects of Metal on Size Specific Dose Estimation (SSDE) in CT: A Phantom Study.

    … dose estimation (SSDE) was introduced by AAPM TG-204 which accounts for the physical size of the patient. However, the approach presented in TG-204 ignores the importance of the attenuation differences in the body. In 2014, a newer methodology that accounted for tissue attenuation was …

    ohiolink Repository record for The Effects of Metal on Size Specific Dose Estimation (SSDE) in CT: A Phantom Study. (opens in a new tab)

  11. Development of Monte Carlo Treatment Planning and Dosimetry System for Small Animal Irradiator

    … in accordance with the recommendations of AAPM TG-61 protocol. Both in-air and in-water calibrations were performed at a 30.5 cm source-to-surface distance (SSD) for the reference applicator 40x40 mm2 square field size. The BEAM/EGS was used to model 225 kV photon beams from a small animal …

    utswmed Repository record for Development of Monte Carlo Treatment Planning and Dosimetry System for Small Animal Irradiator (opens in a new tab)

  12. Avaliação do impacto das estimativas de dose e DLP específico ao tamanho em exames de tomografia computadorizada em pacientes adultos e pediátricos

    … Associação Americana de Físicos em Medicina (AAPM), corrige o índice de dose volumétrico em TC (CTDIVOL), fornecendo uma estimativa mais precisa da dose efetivamente recebida pelo paciente. Inicialmente, o cálculo da SSDE baseava-se no diâmetro efetivo (Deff); entretanto, por este não …

    brazil-ufpe Repository record for Avaliação do impacto das estimativas de dose e DLP específico ao tamanho em exames de tomografia computadorizada em pacientes adultos e pediátricos (opens in a new tab)

  13. Development of an Innovative Daily QA System for Pencil-Beam Scanning Proton Therapy

    … American Association of Physics in Medicine (AAPM) task group reports. The output has remained within the 3% tolerance and the range was within ±1mm. Spot position has remained within ±2mm. This daily QA procedure is quick and efficient with the time required for setup and delivery at less …

    fau Repository record for Development of an Innovative Daily QA System for Pencil-Beam Scanning Proton Therapy (opens in a new tab)

  14. Dynamic Model-Based Dose Calculations of Permanent Implant Prostate Brachytherapy

    … are implemented for 120 patients. Clinical AAPM TG-43 and static MC dose calculations overestimate D90 values compared to dynamically-calculated dose distributions; these overestimations range from 5 to >30% depending on edema model and patient parameters,e.g., the presence of intraprostatic …

    carleton Repository record for Dynamic Model-Based Dose Calculations of Permanent Implant Prostate Brachytherapy (opens in a new tab)

  15. Estudio de detectores tipo película radiocrómica EBT3 y diodos de Silicio para dosimetría in vivo en irradiación corporal total

    … y factores de corrección recomendadas por la AAPM (Task Group) TG-62 reporte 87 y al sistema óptico-película se le realizaron pruebas de verificación y la curva sensitométrica recomendadas por la AAPM TG-55, en DFS=100 cm y en condiciones de TBI (3.8 m). Se evalúa la exactitud de los sistemas …

    javeriana Repository record for Estudio de detectores tipo película radiocrómica EBT3 y diodos de Silicio para dosimetría in vivo en irradiación corporal total (opens in a new tab)

  16. Implementation of TG-351 Reference Dosimetry for a 6 MV Photon Beam in an MR-Guided Radiotherapy System

    … American Association of Physicists in Medicine (AAPM) Task Group 351 (TG-351) provides a formalism for reference dosimetry in MRgRT. In this study, the TG 351 formalism is used to perform reference dosimetry for a 6 MV flattening filter-free (FFF) photon beam from a Viewray MRIdian MR-Linac …

    vcu Repository record for Implementation of TG-351 Reference Dosimetry for a 6 MV Photon Beam in an MR-Guided Radiotherapy System (opens in a new tab)

  17. Neutron Fluence Measurements of the Siemens Oncor Linear Accelerator Utilizing Gold Foil Activation

    … well, with the jaws closed as is prescribed in AAPM report 19. The neutron fluence values then were used to calculate source strength (Q) along with the respective equivalent doses. The neutron fluence from the 20cm x 20cm field resulted in a Q value of 0.33 x1012 n/Gy. The peripheral dose …

    ohiolink Repository record for Neutron Fluence Measurements of the Siemens Oncor Linear Accelerator Utilizing Gold Foil Activation (opens in a new tab)

  18. MCNP5 Monte Carlo based dosimetry for the Nucletron Iridium-192 high dose-rate brachytherapy source with tissue heterogeneity corrections

    … using the dosimetric parameters recommended by AAPM, Task Group-43. The dose-rates in simulated prostate, bladder and rectum were compared to those obtained in the homogeneous water phantom. Based on the resulting dose differences, it is inferred that TPS algorithms for brachytherapy dose …

    fau Repository record for MCNP5 Monte Carlo based dosimetry for the Nucletron Iridium-192 high dose-rate brachytherapy source with tissue heterogeneity corrections (opens in a new tab)

  19. CLINICAL VALIDATION OF DELIVERY ANALYSIS SOFTWARE FOR PATIENT-SPECIFIC QUALITY ASSURANCE OF RADIXACT (TOMOTHERAPY) TREATMENT

    … Gamma (γ) passing rate analysis (%GP) as per AAPM TG-218. This study analyzed 22 PSQA plans executed on a Radixact machine using ArcCheck phantom and delivery analysis (DA) software. The %GP was calculated using a 3% dose difference (DD), a 2 mm distance-to-agreement (DTA), and a 10% …

    fau Repository record for CLINICAL VALIDATION OF DELIVERY ANALYSIS SOFTWARE FOR PATIENT-SPECIFIC QUALITY ASSURANCE OF RADIXACT (TOMOTHERAPY) TREATMENT (opens in a new tab)

  20. Kilo-Voltage X-Ray Correction Factors for In-Water Measurements Based on TG-61

    For x-ray tube potentials 100 kV, the AAPM TG-61 protocol for 40-300 kV x-ray beam dosimetry in radiotherapy recommends an in-water measurement which is based on ionization chambers calibrated in air in terms of air kerma. The variation of the overall correction factor (PQ;cham) and its components …

    carleton Repository record for Kilo-Voltage X-Ray Correction Factors for In-Water Measurements Based on TG-61 (opens in a new tab)

Page 1 of 4