Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 67 for “"AAPM"”
-
Effectiveness of Advanced and Authenticated Packet Marking Scheme for Trace back of Denial of Service Attacks
Advanced and Authenticated Packet Marking (AAPM) scheme is one of the proposed packet marking schemes for the traceback of Denial of Service (DoS) attacks. AAPM uses hash functions to reduce the storage space requirement for encoding of router information in the IP header. In this paper we take the …
-
REEVALUATION OF THE AAPM TG-43 BRACHYTHERAPY DOSIMETRY PARAMETERS FOR AN <sup>125</sup>I SEED, AND THE INFLUENCE OF EYE PLAQUE DESIGN ON DOSE DISTRIBUTIONS AND DOSE-VOLUME HISTOGRAMS
The TG-43 dosimetry parameters of the AdvantageTM 125I model IAI-125A brachytherapy seed were studied. An investigation using modern MCNP radiation transport code with updated cross-section libraries was performed. Twelve different simulation conditions were studied for a single seed by varying the …
-
Application of ab initio calculations to collagen and brome mosaic virus
… the method we call the Amino-Acid Based Method (AAPM) of OLCAO. In brief, the AAPM calculates electronic, self-consistent fi eld (scf) potentials for individual amino-acids with their neighboring amino-acids included as a boundary condition. This allows the costly scf part of the calculation to …
-
ANALYSIS OF ADJUSTED AND ADVANCED PACKET MARKING SCHEMES FOR TRACEBACK OF DENIAL OF SERVICE ATTACKS
… Advanced and Authenticated Packet Marking (AAPM) is another proposed marking scheme traceback of DoS attacks. AAPM uses hash functions to reduce the storage space requirement for encoding of the router IP address into the marking field of the IP packets. Here, a study is presented from the …
-
Διασφάλιση Ποιότητας στη Λειτουργική Μαγνητική Απεικόνιση - fMRI
… συστήματος, σύμφωνα με τα πρωτόκολλα της AAPM και του FBIRN, μακροπρόθεσμα και βραχυπρόθεσμα, καθώς επίσης και την συμπεριφορά του με χρήση κάποιων παραμέτρων και εξαρτημάτων, όπως τα συνήθη φώτα, τον δυναμικό φωτισμό μαζί με τον βιντεοπροβολέα του συστήματος και τη χρήση του …
-
Quality Assurance Procedures Implementation for Varian TrueBeam
… ensure that patients receive quality care. The AAPM (American Association of Physicists in Medicine (AAPM) Task Group (TG) 142 recommends daily, monthly, and annual QA of the linear accelerators with predesignated tolerances for non-IMRT, IMRT, and SRS/SBRT treatment techniques. In the Oncology …
-
142pr glass seeds for the brachytherapy of prostate cancer
… American Association of Physicists in Medicine (AAPM) TG-43/60. The Monte Carlo calculation results were compared with those from a dose point kernel code. The dose profiles agree well with each other. The gamma dose of 142Pr was evaluated. The gamma dose is 0.3 Gy at 1.0 cm with initial activity …
-
Optimization of Permanent Breast Seed Implant Dosimetry Incorporating Tissue Heterogeneity
… around brachytherapy sources is based on the AAPM TG43 formalism, which generates the dose in homogeneous water medium. Recently, AAPM task group no. 186 (TG186) emphasized the importance of accounting for heterogeneities. In this work we introduce an analytical dose calculation algorithm in …
-
Avaliação dos equipamentos de ultrassonografia da região metropolitana do Recife
… pela Associação Americana de Física Médica (AAPM), uma vez que não há no país um protocolo para estes testes. Neste trabalho foi efetuado o levantamento dos dados dos equipamentos com relação à idade e tipo de transdutor, bem como condições e causas de manutenção.Foram também avaliados os …
-
The Effects of Metal on Size Specific Dose Estimation (SSDE) in CT: A Phantom Study.
… dose estimation (SSDE) was introduced by AAPM TG-204 which accounts for the physical size of the patient. However, the approach presented in TG-204 ignores the importance of the attenuation differences in the body. In 2014, a newer methodology that accounted for tissue attenuation was …
-
Development of Monte Carlo Treatment Planning and Dosimetry System for Small Animal Irradiator
… in accordance with the recommendations of AAPM TG-61 protocol. Both in-air and in-water calibrations were performed at a 30.5 cm source-to-surface distance (SSD) for the reference applicator 40x40 mm2 square field size. The BEAM/EGS was used to model 225 kV photon beams from a small animal …
-
Avaliação do impacto das estimativas de dose e DLP específico ao tamanho em exames de tomografia computadorizada em pacientes adultos e pediátricos
… Associação Americana de Físicos em Medicina (AAPM), corrige o índice de dose volumétrico em TC (CTDIVOL), fornecendo uma estimativa mais precisa da dose efetivamente recebida pelo paciente. Inicialmente, o cálculo da SSDE baseava-se no diâmetro efetivo (Deff); entretanto, por este não …
-
Development of an Innovative Daily QA System for Pencil-Beam Scanning Proton Therapy
… American Association of Physics in Medicine (AAPM) task group reports. The output has remained within the 3% tolerance and the range was within ±1mm. Spot position has remained within ±2mm. This daily QA procedure is quick and efficient with the time required for setup and delivery at less …
-
Dynamic Model-Based Dose Calculations of Permanent Implant Prostate Brachytherapy
… are implemented for 120 patients. Clinical AAPM TG-43 and static MC dose calculations overestimate D90 values compared to dynamically-calculated dose distributions; these overestimations range from 5 to >30% depending on edema model and patient parameters,e.g., the presence of intraprostatic …
-
Estudio de detectores tipo película radiocrómica EBT3 y diodos de Silicio para dosimetría in vivo en irradiación corporal total
… y factores de corrección recomendadas por la AAPM (Task Group) TG-62 reporte 87 y al sistema óptico-película se le realizaron pruebas de verificación y la curva sensitométrica recomendadas por la AAPM TG-55, en DFS=100 cm y en condiciones de TBI (3.8 m). Se evalúa la exactitud de los sistemas …
-
Implementation of TG-351 Reference Dosimetry for a 6 MV Photon Beam in an MR-Guided Radiotherapy System
… American Association of Physicists in Medicine (AAPM) Task Group 351 (TG-351) provides a formalism for reference dosimetry in MRgRT. In this study, the TG 351 formalism is used to perform reference dosimetry for a 6 MV flattening filter-free (FFF) photon beam from a Viewray MRIdian MR-Linac …
-
Neutron Fluence Measurements of the Siemens Oncor Linear Accelerator Utilizing Gold Foil Activation
… well, with the jaws closed as is prescribed in AAPM report 19. The neutron fluence values then were used to calculate source strength (Q) along with the respective equivalent doses. The neutron fluence from the 20cm x 20cm field resulted in a Q value of 0.33 x1012 n/Gy. The peripheral dose …
-
MCNP5 Monte Carlo based dosimetry for the Nucletron Iridium-192 high dose-rate brachytherapy source with tissue heterogeneity corrections
… using the dosimetric parameters recommended by AAPM, Task Group-43. The dose-rates in simulated prostate, bladder and rectum were compared to those obtained in the homogeneous water phantom. Based on the resulting dose differences, it is inferred that TPS algorithms for brachytherapy dose …
-
CLINICAL VALIDATION OF DELIVERY ANALYSIS SOFTWARE FOR PATIENT-SPECIFIC QUALITY ASSURANCE OF RADIXACT (TOMOTHERAPY) TREATMENT
… Gamma (γ) passing rate analysis (%GP) as per AAPM TG-218. This study analyzed 22 PSQA plans executed on a Radixact machine using ArcCheck phantom and delivery analysis (DA) software. The %GP was calculated using a 3% dose difference (DD), a 2 mm distance-to-agreement (DTA), and a 10% …
-
Kilo-Voltage X-Ray Correction Factors for In-Water Measurements Based on TG-61
For x-ray tube potentials 100 kV, the AAPM TG-61 protocol for 40-300 kV x-ray beam dosimetry in radiotherapy recommends an in-water measurement which is based on ionization chambers calibrated in air in terms of air kerma. The variation of the overall correction factor (PQ;cham) and its components …
Page 1 of 4