Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 18 of 18 for “"AC mains"”

  1. An on-line UPS with improved input-output characteristics

    … systems are connected in series between the ac mains and the critical load. A phase controlled rectifier feeds a battery supported dc bus and an inverter supplies the load. These systems require two conversion stages thus reducing operating efficiency. Moreover, input power factor is poor and …

    concordia

  2. AC/DC power conversion schemes with unity power factor and minimum harmonic distortion

    In most line-interfaced power converter applications the ac mains voltage is first rectified into a dc voltage or current, which is subsequently converted into voltages and currents of appropriate amplitude, frequency and shape to meet the load requirements. The front-end rectifier must satisfy …

    concordia

  3. Hybrid Renewable Energy System with Wind Turbine and PV Panels

    … years. One of the most widely used electric machines used in wind energy conversion systems is the doubly-fed induction generator (DFIG) which requires a source and power converter system to feed variable frequency AC voltage to its rotor. Power converter schemes currently used with DFIGs, …

    ndsu Repository record for Hybrid Renewable Energy System with Wind Turbine and PV Panels (opens in a new tab)

  4. Hybrid Renewable Energy System Using Doubly-Fed Induction Generator and Multilevel Inverter

    The proposed hybrid system generates AC power by combining solar and wind energy converted by a doubly-fed induction generator (DFIG). The DFIG, driven by a wind turbine, needs rotor excitation so the stator can supply a load or the grid. In a variable-speed wind energy system, the stator voltage …

    ndsu Repository record for Hybrid Renewable Energy System Using Doubly-Fed Induction Generator and Multilevel Inverter (opens in a new tab)

  5. The study of single phase diode rectifiers with high power factor and low total harmonic distortion

    The mains current in an ac/dc converter contains periodic current pulses due to the action of rectifier and output filter capacitor. The high current peaks cause harmonic distortion of the supply current and low power factor. This results in a poor power quality, voltage distortion, poor power …

    missouri Repository record for The study of single phase diode rectifiers with high power factor and low total harmonic distortion (opens in a new tab)

  6. The parallel connection of single phase DC to AC power converters

    Electrical power converter subsystems are placed between an ac-mains bus and a load in order to condition the power being transferred, to protect the load and the ac source, and to provide uninterruptible power supply (UPS) features. One method of providing the required interface in, low to medium …

    concordia

  7. Innovative Power Line Communication Solutions for Enhancing Safety and Signal Integrity in Single Wire Earth Return Systems

    … ground, electric current flows through the contact surface, forming an electric arc causing bushfire hazards and posing a threat to human life. The detection of such disturbances has long been a challenge for engineers with no conclusive solution. This thesis seeks to develop a reliable method …

    vu-aus Repository record for Innovative Power Line Communication Solutions for Enhancing Safety and Signal Integrity in Single Wire Earth Return Systems (opens in a new tab) Embargoed until 2027-06-03

  8. Data communications using coherent minimum frequency shift keying on intrabuilding polyphase power line networks

    … power distribution circuits is examined. An actual modem was designed and implemented. Average bit error rate (BER) versus received Eb/No measurements were taken for an industrial, commercial, and residential power line environments at 1.2kbps, 4.8kbps, and 19.2kbps data rate. The 19.2kbps …

    ubc Repository record for Data communications using coherent minimum frequency shift keying on intrabuilding polyphase power line networks (opens in a new tab)

  9. Evaluation and Design of High Frequency Transformers for On Board Charging Applications

    … electric vehicles is steadily increasing. This accelerates the development of infrastructure and related systems, such as chargers. When connecting the charging port directly to the grid, chargers integrated into the vehicles converts the AC mains to correct battery voltage and regulates the …

    chalmers Repository record for Evaluation and Design of High Frequency Transformers for On Board Charging Applications (opens in a new tab)

  10. High-performance control for power conversion topologies in battery charging applications

    … is transforming toward electric mobility at an accelerated speed. Rapid charging systems are one of the critical enablers for the electrification of transportation. Therefore, developing high-power and highly efficient battery chargers has attracted significant attention. New power electronic …

    ubc Repository record for High-performance control for power conversion topologies in battery charging applications (opens in a new tab)

  11. Back to Back Active Power Filter for Multi-Generator Power Architecture with Reduced dc-link Capacitor

    … effectively eliminates 5th and 7th harmonics. It achieves a significant size and weight reduction compared to a 12-pulse converter while keep the comparable harmonic cancellation performance. Recently, a hybrid type front-end was proposed. On top of the passive front-end, 3 phase active power …

    vt Repository record for Back to Back Active Power Filter for Multi-Generator Power Architecture with Reduced dc-link Capacitor (opens in a new tab)

  12. A new unity power factor quasi-resonant induction heater

    … The proposed three phase unity power factor induction heating system consists of two stages of power conversions. The important requirements for each stage of the power conversion of a typical induction heating system working from a three-phase supply are identified. A wide range of …

    southwales Repository record for A new unity power factor quasi-resonant induction heater (opens in a new tab)

  13. Fast charging techniques and compact integrated implementations for electrochemical double layer capacitors in portable applications

    … Li-Ion, etc.) they all have one serious drawback in common, in terms of charging time. Electrochemical double layer capacitors (EDLCs) also known as ultracapacitors or supercapacitors seem to have overcome this disadvantage, at the cost of lower energy storage capacity.<br/><br/>This work aims …

    soton Repository record for Fast charging techniques and compact integrated implementations for electrochemical double layer capacitors in portable applications (opens in a new tab)

  14. Permeance based modelling, design and optimization of supercapacitor assisted surge absorber (SCASA)

    Supercapacitor assisted (SCA) techniques are a unique set of circuit topologies designed to fulfil power conversion and protection tasks by circumventing the energy losses normally associated with RC based circuits. With million times larger capacitance compared to electrolytic type, …

    waikato-masters Repository record for Permeance based modelling, design and optimization of supercapacitor assisted surge absorber (SCASA) (opens in a new tab)

  15. Single-Sensor DCM PFC Based Onboard Chargers for Low Voltage Electric Vehicles

    … chargers consist of power converters to convert AC voltage (grid) to constant DC voltage (battery). The existing chargers are bulky, have high components’ count, complex control system and poor input power quality. Henceforth, to overcome these drawbacks, this thesis focuses on the onboard …

    concordia

  16. LPTV-Aware Bit Loading and Channel Estimation in Broadband PLC for Smart Grid

    … time varying (LPTV) behavior synchronous to the AC mains cycle. This is due to the time varying impedances of electrical devices that are connected to the power grid. Another challenge is the impulsive noise in addition to power line background noise, which is due to switching events in the power …

    ku Repository record for LPTV-Aware Bit Loading and Channel Estimation in Broadband PLC for Smart Grid (opens in a new tab)

  17. Etude d'une structure d'interrupteur 4 quadrants à faibles pertes à base de transistors à forts gains

    … alternatif 230V/50Hz. Il n’existe pas à l’heure actuelle de composants interrupteurs monolithiques de ce type. La première partie du mémoire présente les interrupteurs électroniques existants. La deuxième partie, traite des interrupteurs électroniques à base de transistors MOS et des limites de …

    star-france Repository record for Etude d'une structure d'interrupteur 4 quadrants à faibles pertes à base de transistors à forts gains (opens in a new tab)

  18. Power electronic supplies for public lighting systems with distributed generation capability: solution proposals for power and minimization of the impact in grid quality

    … Proposals For Power And Control Stages, Characterization And Minimization Of The Impact In Grid Quality”, has been developed as one of the core research activities of the Efficient Energy Conversion, Industrial Electronics and Lighting Engineering group (CE3I2), from the Electrical …

    oviedo Repository record for Power electronic supplies for public lighting systems with distributed generation capability: solution proposals for power and minimization of the impact in grid quality (opens in a new tab)