Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 100 for “"AC systems"”.

  1. Reduced Reference Frame for AC Systems

    … reference frame for the analysis of electrical machines, the decomposition into symmetrical sequence components using the Fortescue transformation for the study of asymmetrical short circuits, and the use of the Clarke transformation for the control of power converters are good examples where the …

    sevilla Repository record for Reduced Reference Frame for AC Systems (opens in a new tab)

  2. Adaptive Phase Locked Loops for VSC connected to weak ac systems

    The performance of the High voltage dc systems is dependent on the stiffness of the ac bus, it is connected to. With the traditional synchronous reference frame-phase locked loops (SRF-PLL), voltage source converters (VSC) systems with large PLL gains, connected to weak ac networks are shown to be …

    manitoba Repository record for Adaptive Phase Locked Loops for VSC connected to weak ac systems (opens in a new tab)

  3. EMTP simulation of an HVDC system operating with weak AC systems

    … simulation of an HVDC system operating with weak ac systems, such as generating signals, converter modelling, and gamma measuring circuits.

    concordia Download PDF for EMTP simulation of an HVDC system operating with weak AC systems (opens in a new tab)

  4. A converter-enhanced synchronous compensator for LCC-HVDC links feeding weak AC systems

    … high Short-Circuit Ratios and demand extensive reactive power. Conventional synchronous condensers (SCs) provide reactive support and physical inertia but suffer from slow dynamics and high maintenance. Conversely, STATCOMs deliver fast voltage support but lack inherent inertial response. This …

    manitoba Repository record for A converter-enhanced synchronous compensator for LCC-HVDC links feeding weak AC systems (opens in a new tab)

  5. Impedance-Based Stability Analysis and Controller Design of Three-Phase Inverter-Based Ac Systems

    … widely used for energy conversion in three-phase ac systems, such as renewable energy systems and microgrids. These three-phase inverter-based ac systems may suffer from small-signal instability issues due to the dynamic interactions among inverters and passive components in the systems. It is …

    utk-theses Repository record for Impedance-Based Stability Analysis and Controller Design of Three-Phase Inverter-Based Ac Systems (opens in a new tab)

  6. DQ-Frame Small-Signal Stability Analysis of AC Systems with Single-Phase and Three-Phase Converters

    … This dissertation presents a novel approach to modeling and comprehensive stability analysis for both single-phase and three-phase converters, addressing vital gaps in the existing literature. The first part of the dissertation (Chapters 2 to 4) focuses on single-phase power supply units, …

    vt Repository record for DQ-Frame Small-Signal Stability Analysis of AC Systems with Single-Phase and Three-Phase Converters (opens in a new tab)

  7. Securing Approximate Computing Systems

    Approximate Computing (AC) techniques have been leveraged to improve computing performance and energy efficiency with minor degradation in accuracy. Different than conventional computing, AC allows the computation to deviate from the reference or deterministic execution behavior. Thus, AC has …

    unh-thes Repository record for Securing Approximate Computing Systems (opens in a new tab)

  8. ΜΕΘΟΔΟΙ ΒΕΛΤΙΩΣΗΣ ΤΗΣ ΜΕΤΑΒΑΤΙΚΗΣ ΕΥΣΤΑΘΕΙΑΣ ΣΥΝΘΕΤΩΝ ΗΛΕΚΤΡΙΚΩΝ ΣΥΣΤΗΜΑΤΩΝ ΕΝΑΛΛΑΣΟΜΕΝΟΥ - ΣΥΝΕΧΟΥΣ ΡΕΥΜΑΤΟΣ

    WEAK AC SYSTEMS SUPPLIED BY HVDC LINKS SUFFER VOLTAGE STABILITY PROBLEMS AT THEINVERTER BUS TERMINAL DURING SYSTEM DISTURBANCES. IN THESE CASES THE FAST VARIATION OF THE ACTIVE POWER TRANSMITTED BY THE HVDC LINKS RESULTS IN LARGE VARIATION OF THE REACTIVE POWER ABSORBED BY THE INVERTER AND …

    greece Repository record for ΜΕΘΟΔΟΙ ΒΕΛΤΙΩΣΗΣ ΤΗΣ ΜΕΤΑΒΑΤΙΚΗΣ ΕΥΣΤΑΘΕΙΑΣ ΣΥΝΘΕΤΩΝ ΗΛΕΚΤΡΙΚΩΝ ΣΥΣΤΗΜΑΤΩΝ ΕΝΑΛΛΑΣΟΜΕΝΟΥ - ΣΥΝΕΧΟΥΣ ΡΕΥΜΑΤΟΣ (opens in a new tab)

  9. Proposed exergetic based leak detection and diagnosis methodology for automotive carbon dioxide air conditioning systems

    … of global warming and ozone depletion, the replacement of many currently used refrigerants is a pressing matter within all sectors of refrigeration. Presently, the hydroflourocarbon (HFC) 134a, the working fluid of automotive air conditioning (AC) systems, greatly contributes to global warming …

    rit Repository record for Proposed exergetic based leak detection and diagnosis methodology for automotive carbon dioxide air conditioning systems (opens in a new tab)

  10. Real-time and non-real-time EMT simulation of an alternate arm converter

    … energy balancing in an alternate arm converter (AAC) using detailed real-time and non-real-time electromagnetic transient (EMT) models. A method for regulating submodule capacitor voltages and maintaining energy balance between the ac and dc systems is developed and fully analyzed using detailed …

    manitoba Repository record for Real-time and non-real-time EMT simulation of an alternate arm converter (opens in a new tab)

  11. Fuzzy based computational models of emotion for monitoring students' affective trajectories

    Affective computing (AC) is an emerging multidisciplinary field, which aims to bridge the gap between the highly emotional human and the emotionally challenged computer, in order to provide a higher level of human machine interaction. This Thesis contributes to AC research by proposing new emotion …

    greece Repository record for Fuzzy based computational models of emotion for monitoring students' affective trajectories (opens in a new tab)

  12. Nucleate boiling characteristics of R-113 in a small enhanced tube bundle.

    … enhanced tube bundle in a pool of R-l 13. By accurately instrumenting five tubes within the bundle, both the convective and nucleate boiling regions were studied in detail, with emphasis on the 'bundle' effect (i.e. the effect of lower tubes in operation on upper tubes within the bundle). In …

    nps Repository record for Nucleate boiling characteristics of R-113 in a small enhanced tube bundle. (opens in a new tab)

  13. FREQUENCY CONTROL STUDIES IN AC-DC SYSTEMS

    Isolated alternating current power systems may be interconnected for energy exchange by either alternating current or direct current lines. A dc tie line is asynchronous in that the power transfer over it is not inherently dependent upon the relationship between the frequencies at the two ends of …

    sask Repository record for FREQUENCY CONTROL STUDIES IN AC-DC SYSTEMS (opens in a new tab)

  14. Nucleate pool boiling of R-114 and R-114/oil mixtures from single enhanced tubes

    … can be improved by using enhanced boiling surfaces. This thesis looks at the pool boiling characteristics of R-114 (presently used in large shipboard AC systems) from 10 enhanced single copper tubes and compares performance with a smooth copper tube. Since small amounts of oil escape into the …

    nps Repository record for Nucleate pool boiling of R-114 and R-114/oil mixtures from single enhanced tubes (opens in a new tab)

  15. Control Strategies for Minimizing the DC-Link Capacitance in Power Electronics Converters for Aircraft Electrical Power Systems

    … the electrical power system (EPS) consists of AC and DC power distribution systems to deliver power to various aircraft loads. In main power generation, variable frequency generators (VFGs) generate VF AC supply (380-800Hz 115/230V) to feed frequency insensitive loads. The VF AC is also …

    houston Repository record for Control Strategies for Minimizing the DC-Link Capacitance in Power Electronics Converters for Aircraft Electrical Power Systems (opens in a new tab)

  16. ENERGY SAVINGS AND THERMAL COMFORT OF SEPARATE SENSIBLE AND LATENT COOLING AIR-CONDITIONING SYSTEMS

    Conventional air conditioning (AC) systems have limited control of sensible cooling and latent cooling capacities; therefore additional energy-consuming devices, i.e. electric heaters, are often used to reheat the conditioned air in order to provide thermal comfort for the building occupants. …

    maryland Repository record for ENERGY SAVINGS AND THERMAL COMFORT OF SEPARATE SENSIBLE AND LATENT COOLING AIR-CONDITIONING SYSTEMS (opens in a new tab)

  17. Elimination of slack bus iteration/droop bus iteration in sequential ac-dc power flow algorithm

    … renewable energy over long distances into AC grid. It uses power electronics technology to convert the electric power from AC systems into DC and then transmits this power over long distances and finally converts back DC into AC systems to inject power into AC grid. Current-Sourced …

    ubc Repository record for Elimination of slack bus iteration/droop bus iteration in sequential ac-dc power flow algorithm (opens in a new tab) Download PDF for Elimination of slack bus iteration/droop bus iteration in sequential ac-dc power flow algorithm (opens in a new tab)

Page 1 of 5