Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 13 of 13 for “"AC-electroosmosis"”.
-
AC Electroosmosis for Lab-On-a-Chip Applications
<p>AC electrokinetics is the study of a particle and fluid motion induced by AC electric fields. In the last decade it has received increasing interest due to its important applications in micro total analysis systems and miniaturized biomedical devices. With the application of very low voltage …
-
Design and fabrication of a new 3D AC-electroosmotic micropump
… solid-state electrokinetic micropumps.<br/><br/>AC Electrokinetic micropumps in particular AC electroosmosis pump can be used to pump fluids using planar electrodes which induce electrical forces on the fluid. However, planar electrodes have limited pumping capability of the …
-
ELECTROCHEMICAL PROCESSES IN MICROFLUIDICS SYSTEMS UNDER AC ELECTRIC FIELDS
Alternating current (AC) electric signal has been widely applied in microfluidic systems to induce AC electrokinetic behavior. AC electrokinetic phenomena including AC electrophoresis, AC dielectrophoresis, AC electroosmosis flow and AC electrothermal flow are widely applied in (bio)particle …
-
Alternating Current Electroosmotic Micropumping Using A Square Spiral Microelectrode Array
… microelectrode array which uses the principal of AC electroosmosis (EO), ions driven along microelectrode surfaces by coulomb forces produced by tangential electric fields. These ions, when driven, induce a net fluid motion due to viscous drag forces. Three submerged microelectrode wires were …
-
IN-LINE MICROFLUIDIC PARTICLE PRECONCENTRATOR AND DETECTOR FOR CONTINUOUS FLOW MONITORING
… of particulate flows. The three devices are AC electrokinetic (ACEK) and acoustic sample preconcentration techniques for resettable particle enrichment, and an in-line somatic cell counter for mastitis monitoring.</p> <p>For the ACEK preconcentrator, ACEK is a new and promising technique to …
-
Fast and Sensitive Detection of Bacteria by Means of AC Electrokinetics and Micro-Raman Spectroscopy
… as possible. In the present thesis, a surface-based method that can provide early and label-free detection of target microorganisms in water is presented. The method combines three key features, namely, (a) accelerated transportation to, and focusing of bacteria on, the detection surface by …
-
An Integrative Approach to Elucidating the Governing Mechanisms of Particles Movement under Dielectrophoretic and Other Electrokinetic Phenomena
Dielectrophoresis (DEP) has been a subject of active research in the past decades and has shown promising applications in Lab-on-Chip devices. Currently researchers use the point dipole method to predict the movement of particles under DEP and guide their experimental designs. For studying the …
-
Microfluidic manipulation by AC Electrothermal effect
<p>AC Electrokinetics (ACEK) has attracted much research interest for microfluidic manipulation for the last few years. It shows great potential for functions such as micropumping, mixing and concentrating particles. Most of current ACEK research focuses on AC electroosmosis (ACEO), which is …
-
Finite Element Studies of Colloidal Mixtures Influenced by Electric Fields
… gap at median frequencies of 1kHz (indicating ac electroosmotic force domination) and began to be pushed back toward the gap at higher frequencies of 100 kHz (indicating dielectrophoretic force intensification). Particle shape effects were examined by calculating the electrical interparticle …
-
Study on dielectrophoretic behavior of a cell with sampling-based analysis for antimicrobial susceptibility test
… evaluate antibiotics effectiveness for treating bacterial infection. These infections may contain drug resistant cells which can render certain antibiotics powerless. For effective patient treatment, a rapid, simple, and reliable susceptiblity test is critically needed. These susceptibility tests …
-
Flujos de electrolitos generados por microelectrodos sometidos a una onda de potencial viajera (Travelling-wave electrokinetic micropumps)
… sujetos a potenciales de onda viajera. La motivación de este trabajo es doble: la tecnología del Laboratorio en un Chip requiere el desarrollo de métodos de control de fluidos en microsistemas y, por otro lado, experimentos recientes con arrays de microelectrodos muestran comportamientos que no …
-
Study of Electrokinetic Response for Drug Susceptibility of Mycobacterium Tuberculosis Complex Cells
… population and claiming over a million lives each year. Drug resistance emerges from gene mutations and improper treatment regimens of the drug-susceptible patients, which is transmitted to others when left undetected and untreated. Testing every patient for drug-resistance would be ideal; …
-
Study of Electrokinetic Response for Drug Susceptibility of Mycobacterium Tuberculosis Complex Cells
… population and claiming over a million lives each year. Drug resistance emerges from gene mutations and improper treatment regimens of the drug-susceptible patients, which is transmitted to others when left undetected and untreated. Testing every patient for drug-resistance would be ideal; …