Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 16 of 16 for “"ACI 318-11"”
-
Introduction to concrete anchor rods
… Code Requirements for Structural Concrete, ACI 318-11, Appendix D. These anchors are used to transmit tension and shear forces by using an individual anchor or a multiple anchor group. For contractors, anchor installation marks the transition between concrete and steel construction. Various …
-
Porovnání návrhu ŽB konstrukcí podle EN a ACI
… 1992-1-1 (EC2) a norma dle amerických standardů ACI 318-11. V rámci práce byly posouzeny sloupy v druhém podzemním podlaží a v prvním nadzemním podlaží. Dále byla posouzena lokálně podepřená deska nad 1NP a schodiště spojující jednotlivá patra. Všechny řešené prvky byly posuzovány dle 1. mezního …
-
Examining the effects of openings at the base of slender reinforced concrete (tilt-up) wall panels subjected to varying wind pressures
… accordance with the American Concrete Institute (ACI) Committee 318-11 Building Code Requirements for Structural Concrete Section 14.8 Alternative Design of Slender Walls. The parametric study calculates the reinforcement (longitudinal) required for specific panels in accordance with ACI 318-11 …
-
Experimental Analysis of Continuous Transverse Reinforcement to be used in Structural Concrete Design
… bar prefabricated to meet specified design spacing. CTR has become a point of interest as an alternative to conventional stirrups, hoops and ties in reinforced concrete design. This innovative product is similar to conventional (i.e. circular) spiral reinforcement but has a rectangular cross …
-
Experimental investigation of shear transfer between concrete interfaces
… addition, the shear friction based provisions of ACI 318-11, AASTHO LRFD 2012, and Eurocode 2 were found to provide satisfactory predictions of the ultimate strength of such surfaces with reinforcement ratios less than 0.75 %.
-
Evaluation of punching shear strength design and modelling approaches for slab-column connections
… in the codes. Fir this purpose, the ability of ACI 318-11, TS-500 and Eurocode-2 to estimate punching shear strength was examined in light of experimental results compiled from previous research. Interior and exterior connections were examined in the course of the study. In the second part of …
-
Plastic voided slab systems: applications and design
… while maintaining similar load carrying capacity of a solid slab. Plastic voided slabs are capable of reducing the amount of concrete necessary to construct a building by 30 percent or more. This reduction can be beneficial in terms of financial savings as well as building performance. This …
-
Cracking Behavior of Structural Slab Bridge Decks
… than ten times the maximum limit recommended in ACI 224R-01 for bridge decks exposed to de-icing salts. Measurements using digital image correlation revealed that the cracks widened under truck loading, and in some cases, the cracks did not fully close after unloading. This dissertation includes …
-
Crack Propagation Analysis of a Pre-stressed L-shaped Spandrel Parking Garage Beam
… by use of MathCAD to compute ultimate moment capacity and the cracking moment of the beam based on PCI and ACI 318 codes. According to ACI 318-11, if the ratio of ultimate moment capacity over cracking moment exceeds 1.2, then the structure should be ductile enough to undergo considerable …
-
Seismic Performance of Square Nickel-Titanium Reinforced ECC Columns with Headed Couplers
… capability of the column. The drift capacities of the SMA/ECC columns were at least 33% higher than that of the steel RC column. ECC was effective in minimizing damage to the plastic hinge. Damage in the SMA/ECC columns was limited to a single wide crack at the base that was repairable. …
-
Performance of Full-Scale Reinforced Concrete Columns Subjected to Extreme Earthquake Loading
… were designed according to seismic provisions of ACI 318-11 and featured two different cross sections (36×28 in. and 28×28 in.). Another goal of the program was to investigate the influence of loading history, thus the column specimens were subjected to several large displacement loading …
-
Punching shear of self-consolidated two-way slabs
… in the reinforcement and concrete, ultimate capacity, modes of failure, and crack development. The C/F ratio and maximum aggregate size do not show significant influence on the slab deformation characteristics such as deflection, stiffness, ductility and energy absorption, steel and concrete …
-
Structural integrity assessment of corroded reinforced concrete slab-column connections
… that calculate the residual carrying load capacity for corroded RC two-way slabs. The concrete mixture used to pour those elements was designed to conquer the exposure requirements for horizontal elements against de-icing agents according to ACI. For ensuring the poured concrete had an …
-
Fjaðureiginleikar íslenskrar steinsteypu
… voru saman við staðalgildi bandaríska staðalsins ACI 318-11, var munurinn um 18 %. Mismunur á milli niðurstöðu prófanna ISO 1920-10:2010 og ASTM C 469 var um 12 %. Reiknað Poissons hlutfall fyrir þau sýni sem voru til skoðunar í þessari rannsókn voru að meðaltali: Fyrir C25/30: 0,17. Fyrir C30/37: …
-
Experimental and analytical investigations on seismic behavior of reinforced concrete frames and members using high-strength materials
… according to the special seismic provisions of ACI 318-11 code. The variables in test specimens include the concrete compressive strength, the reinforcement yield strength, and the level of axial compression loading. The test specimens were subjected to constant column axial loading as well as …
-
Study of Hidden Corrosion on Prestressing Strands
… beam was initially designed to provide enough capacity to perform well under the service load. But over the period of time, the beam suffered corrosion due to environmental effects and loading. The flaws in the concrete made the steel strands vulnerable to corrosion attack and the degraded strands …