Optimization of VAV AHU Terminal Box Minimum Airflow
… and cooling, and consume more fan power in the AHUs. If the minimum airflow is set lower than required, indoor air quality (IAQ) will be a concern. Energy saving ratio study is conducted to estimate the energy saving benefit by implementing an optimized minimum airflow.
-
Characterization of HVAC operation uncertainty in EnergyPlus AHU modules
This study addresses 5 uncertainties that exist in the operation of HVAC systems, which will presumably affect the actual energy consumption of the HVAC system in comparison to the consumption under idealized bahavior. We consequently add these parameters and their uncertainty range into the source …
-
An Examination of the Relationship Between Rapa Nui Ahu and Topography Using Structure from Motion GIS
… island's giant statues ( moai) and platforms ( ahu) showing that they were purposeful projects created by small communities around the island. What remains unclear, however, is the full meaning and purpose of the giant structures created by the ancient Rapanui. A current working theory is that …
-
Would the Proposed Reforms Affecting Ahu Whenua Trusts Have Impeded Hapū in the Development of Their Lands? A Ngāti Awa Perspective
… Zealand), of how changes to important aspects of ahu whenua trusts under Te Ture Whenua Māori Bill 2016 might have impeded hapū in achieving their land utilisation objectives. This form of trust, established under Te Ture Whenua Māori Act 1993, is the principal vehicle for Māori land management …
-
An investigative analysis of an advanced trim and respond control strategy for variable air volume HVAC systems
… TTR and FSP comparison were as follows: Boone RC AHU-1 20.86% and AHU-2 10.69%, Des Moines MEPS AHU-1 27.30%, JFHQ AHU-1 4.73%, AHU-4 12.83%, AHU-9 59.92% and AHU-12 15.83%, Muscatine AFRC RTU-1 18.91%, RTU-3 29.46%, RTU-4 36.54% and Waterloo RC RTU-1 33.80%. The fan energy savings results of the …
-
SELECTION CRITERIA FOR CENTRAL AND INDIVIDUAL AIR HANDLING UNITS FOR A TALL AIR-CONDITIONED BUILDING
For complex high rise buildings, the selection of AHU requires a thorough understanding of various building elements. Multi-storey buildings tend to have higher skin-to-floor ratios than shorter, more compact structures of equal floor area and their performance is influenced by design decisions. …
-
te ‘ori tahiti e te ‘ahu: Public Performances of Tahitian Dance and Costuming Innovations During the Height of French Colonialism in Tahiti, 1880-1910
In Tahiti in 1956, Madeleine Moua founded the Heiva dance troupe and made bold costuming changes, replacing the modest Western clothes worn throughout the last century of dance. Historians and cultural scholars attribute this moment as one of the central components that kickstarted the indigenous …
-
Fault Detection and Diagnostics in Single-Duct Multiple-Zone Variable Air Volume Air Handling Unit Systems
Variable air volume (VAV) air handling unit (AHU) systems are the most common heating, ventilation, and air conditioning (HVAC) configuration in North America's commercial buildings. They account for a large fraction of sensors and actuators and are prone to faults due to their control systems' …
-
Application of the Andersen Health System Utilization Framework in the Investigation of the use of Traditional Medicine in Kumasi, Ghana
… (LMIC). The Andersen Health System Utilization (AHU) framework was used to explore the factors associated with TM use among chronically ill patients seeking care from the Komfo Anokye Teaching Hospital (KATH), Ghana, West Africa. Two research questions allowed a focused application of the AHU …
-
Process monitoring and fault classification for an air handling unit
… identify system faults in an air-handling unit (AHU). The effects of using a reduced amount of available information are investigated. The faults are simulated and are applied in an actual flow loop facility;The process model fault scheme as presented in Iserman (1987) was adopted for this …
-
A plug and play framework for an HVAC air handling unit and temperature sensor auto recognition technique
… temperature sensors in an Air Handling Unit (AHU) at different locations. The algorithm can be a critical part of the self-configuring HVAC control system in establishing a binding list of control system input/output and automated assignment and verification of the binding list.</p> <p>A …
-
Interrelation of Prehistoric Wells, Groundwater Resources, and Statues on Easter Island Imply Intrinsic Understanding of Natural Landscape by Rapanui People
… previously mapped locations ofmoai (statues) and ahu (statue platforms). The puna are found within 50 meters of a moai or ahu presentation. Additionally, in these areas fresh, potable groundwater seeps into the sea. This correlation of puna, potable water, and ahu with moai suggests a connection …
-
Development of an integrated air handling system for large commercial buildings
… As one solution to this problem, an all-air AHU system for large commercial building, named Integrated Office Air Handling Unit (OAHU) system, has been developed in this study. This dissertation covers: Description of the new system. A summary of conventional AHU systems for large commercial …
-
Fault detection and diagnostics modeling for air-handling units on the main campus of The University of Texas at Austin
… controlled environmental requirements. Faults in AHUs can occur due to failures in equipment, actuators, or sensors and feedback controllers. Leakage typically occurs due to faults in ducts, faults with valves that are stuck, broken, or in the incorrect operating position, faults in measurements …
-
Holistic Study of Thermal Management in Direct Liquid Cooled Data Centres: from the Chip to the Environment
… to the environment using an Air Handling Unit (AHU). The AHU was fitted with a water spray system to increase the heat transfer capacity. The designed DCLC system was tested and characterised in terms of power consumption and thermal performance. The design successfully provided stable inlet …
-
Characterization of Heat Transfer Rates in an Air to Phase Change Material Thermal Storage Unit for Integration in Air Handling Units
… used to simulate a PCM TES integrated into an AHU using the integration method of strategic heating with the goal of reducing peak power during start-up. The simulation results were compared to the AHU without PCM TES to determine whether any energy improvements were achieved. It was determined …
-
A Quantitative Model-Based Fault Detection & Diagnostics (FDD) System for Zone-Level Inefficiencies
… and an excessive amount of air handling unit (AHU) fan energy consumption was detected. The redundancy of these faults in the building force the AHU to expend an unwarranted amount of energy, highlighting the importance of utilizing FDD. Benefits of this methodology include the detection of …
-
Walk with me : a performative investigation, researching contested memories at New Zealand's national site for remembrance, Puke Ahu : an exegesis presented in partial fulfilment of the requirements for the degree of Master of Fine Arts at Massey University, Wellington, New Zealand
… myths at the new National Memorial Park (Puke Ahu). The project has revealed the ongoing effects of colonialism and offers participants an alternative to the memory formed by the focus on New Zealand’s involvement in overseas wars. The Government’s spending on commemoration of the First World …
-
A Methodology for Automating the Implementation of Advanced Control Algorithms Such As Model Predictive Control on Large Scale Building HVAC Systems
… – cooling towers, chillers, Air Handling Units (AHUs), fans dampers, etc. Improving the performance of these components has the potential for large energy and cost savings. Implementing better control methodologies for regulating these components can be the first step in this direction for …