Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 42 for “"ASCE 41"”.

  1. Evaluation of Seismic Assessment Procedures for Existing Reinforced Concrete Structures Damaged in the 2016 Meinong Earthquake

    … procedures, including the well-established ASCE 41 Tier 1 (preliminary screening) and a new process funded by FEMA and developed by ATC for the city of Los Angeles: ATC 78-7. The second phase of the study investigated the ASCE 41 Tier 3 procedure to determine seismic vulnerability through …

    washington Repository record for Evaluation of Seismic Assessment Procedures for Existing Reinforced Concrete Structures Damaged in the 2016 Meinong Earthquake (opens in a new tab)

  2. Performance Based Analysis of a Steel Braced Frame Building with Buckling Restrained Braces

    … analysis procedures prescribed in ASCE 41-06. The building was designed based on the standards of the ASCE 7-05 for a typical office building located in San Francisco, CA. Nonlinear modeling parameters and acceptance criteria for buckling restrained brace components were developed …

    calpoly Repository record for Performance Based Analysis of a Steel Braced Frame Building with Buckling Restrained Braces (opens in a new tab)

  3. Performance-Based Analysis of a Reinforced Concrete Shear Wall Building

    … concrete shear wall building was designed per ASCE 7-05, and then the performance was investigated using the four analysis procedures outlined in ASCE 41-06. The proposed building was planned as a 6-story office building in San Francisco, CA. The structural system consisted of a two-way flat …

    calpoly Repository record for Performance-Based Analysis of a Reinforced Concrete Shear Wall Building (opens in a new tab)

  4. Performance Based Analysis of Steel Buildings

    … of two separate building types, designed using ASCE 7-05, using the analysis procedures from ASCE 41-06. The results from the ASCE 41-06 analyses were compared to the expected performance level of Life Safety to determine the adequacy of the ASCE 7-05 design. ASCE 7-05 is intended to result in …

    calpoly Repository record for Performance Based Analysis of Steel Buildings (opens in a new tab)

  5. Diseño por desempeño de 4 edificios de concreto armado con núcleo rígido de 45 pisos en el distrito de San Isidro - Lima

    … según las provisiones internaciones del ASCE 41-17, así mismo se determinó los niveles de desempeño como los procedimientos del ATC-40, ASCE 41-17 y el SEAOC Vision 2000. Se obtuvo como resultado un buen comportamiento estructural para los cuatro edificios en investigación, cumpliendo de …

    upc-peru Repository record for Diseño por desempeño de 4 edificios de concreto armado con núcleo rígido de 45 pisos en el distrito de San Isidro - Lima (opens in a new tab)

  6. Seismic Performance Assessment and Nonlinear Modeling Parameters for Slab-Column Connections

    … tend to be slightly lower than the current ASCE 41-17 acceptance criteria. A nonlinear model monitoring column drift to capture punching shear failure for SC connections was developed to model the lateral load response of SC frames. The comparison between analytical and experimental …

    tamu Repository record for Seismic Performance Assessment and Nonlinear Modeling Parameters for Slab-Column Connections (opens in a new tab)

  7. Análisis y diseño de edificios de concreto armado considerando la rigidez efectiva de sus elementos estructurales

    … Factores de reducción mostrados en ACI 318-14, ASCE 41-13, rigidez dependiente del refuerzo y secciones no agrietadas. Se analizaron estas edificaciones mediante los análisis estático y dinámico lineal descritos en la norma nacional E.030-2016. Los edificios fueron diseñados para todos los 8 …

    upc-peru Repository record for Análisis y diseño de edificios de concreto armado considerando la rigidez efectiva de sus elementos estructurales (opens in a new tab)

  8. Seismic fragility analysis of reinforced masonry buildings

    … to quantify probabilities of exceedance for ASCE 41-06 drifts associated with continued occupancy, life safety, and collapse prevention, performance states. The load-displacement curves (hysteresis) were obtained from quasi-static out-of-plane and in-plane experimental testing by Klingner et …

    colostate Repository record for Seismic fragility analysis of reinforced masonry buildings (opens in a new tab)

  9. Seismic Assessment of Infilled Steel Frames

    … proposed here follows the approach included in ASCE 41-17 for RC frames; however, the equations are different due to the different load-transfer mechanisms and failure patterns of the steel and RC infilled frames. The proposed guidelines are considerably more accurate compared to the guidelines …

    buffalo Repository record for Seismic Assessment of Infilled Steel Frames (opens in a new tab)

  10. Performance-Based Analysis of Steel Buildings: Special Concentric Braced Frame

    … analysis methods and evaluation criteria in ASCE 41-06 were used to evaluate a special concentric braced frame building based on the design standards in ASCE 7-05. A rectangular, six-story office building was evaluated using linear static, linear dynamic, nonlinear static, and nonlinear …

    calpoly Repository record for Performance-Based Analysis of Steel Buildings: Special Concentric Braced Frame (opens in a new tab)

  11. Experimental and Analytical Investigation of Seismic Performance and Retrofit Techniques for Non-Ductile RC Structural Walls

    … a set of strain-based criteria and the current ASCE-41 guidelines. The results of the parametric study indicate a reasonable ability of the strain-based methodology to consistently capture key performance metrics of the backbone curve while maintaining a similar statistical spread and trend to …

    vt Repository record for Experimental and Analytical Investigation of Seismic Performance and Retrofit Techniques for Non-Ductile RC Structural Walls (opens in a new tab)

  12. Non-linear modeling parameters for reinforced concrete columns subjected to seismic loads

    The American Society of Civil Engineers (ASCE) Standard 41-06 Supplement No.1 (2007) assists engineers in modeling and evaluating the non-linear behavior of structures till collapse. Different levels of conservatism were used throughout the standard to produce modeling parameters for different …

    texas Repository record for Non-linear modeling parameters for reinforced concrete columns subjected to seismic loads (opens in a new tab)

  13. Diseño Estructural de una Edificación de Oficinas de 5 Pisos + 2 Sótanos en Lima empleando el Análisis estático No Lineal Pushover

    … análisis estático no lineal Pushover conforme a ASCE 41-13 (2014) para evaluar el desempeño estructural bajo cargas sísmicas graduales. Los resultados mostraron cumplimiento con los requisitos de operación y seguridad de vida según los criterios de Visión 2000 (1995), destacando una adecuada …

    upc-peru Repository record for Diseño Estructural de una Edificación de Oficinas de 5 Pisos + 2 Sótanos en Lima empleando el Análisis estático No Lineal Pushover (opens in a new tab)

  14. Evaluación del desempeño sísmico de una edificación de concreto armado de 5 niveles en la ciudad de Huánuco mediante el análisis estático no lineal (pushover)

    … lineal se realizó de acuerdo con las normativas ASCE 41-23 y FEMA 440. Como resultado, se determinó que la edificación mantiene un nivel de operatividad adecuado frente a un sismo severo. Sin embargo, se obtuvo un factor de reducción de fuerza sísmica (R) entre 1.93 y 2.01, evidenciando una …

    upc-peru Repository record for Evaluación del desempeño sísmico de una edificación de concreto armado de 5 niveles en la ciudad de Huánuco mediante el análisis estático no lineal (pushover) (opens in a new tab)

  15. Evaluación del desempeño sísmico de una vivienda multifamiliar ubicada en Villa Maria del Triunfo, utilizando un análisis estático no-lineal

    … de sismos de acuerdo con los lineamientos de la ASCE 41 y la Norma Peruana de diseño sísmico E-030, y se calcularon espectros de demanda para simular las fuerzas sísmicas que la estructura podría experimentar. Los resultados del análisis modal espectral mostraron que la estructura alcanzó una …

    upc-peru Repository record for Evaluación del desempeño sísmico de una vivienda multifamiliar ubicada en Villa Maria del Triunfo, utilizando un análisis estático no-lineal (opens in a new tab)

  16. ASCE 7–05 Design Rule for Relative Strength in a Tall Buckling-Restrained Braced Frame Dual System

    … codes without compromising ductility. Currently, ASCE 7-05 permits a variety of structural systems to be used in combination as a dual system yet the design requirements are limited to the following statement: Moment frames must be capable of resisting 25% of the seismic forces while the moment …

    calpoly Repository record for ASCE 7–05 Design Rule for Relative Strength in a Tall Buckling-Restrained Braced Frame Dual System (opens in a new tab)

  17. SYSTEM-LEVEL SEISMIC PERFORMANCE QUANTIFICATION OF REINFORCED MASONRY BUILDINGS WITH BOUNDARY ELEMENTS

    … building codes in Canada and the USA (NBCC and ASCE-7) as well as other standards including FEMA P695 (FEMA 2009) (Chapter 2), TMS 402 and CSA S304 (Chapter 3), FEMA P58 (FEMA 2012) (Chapter 4), and ASCE-41 (Chapter 5). Chapter 1 of the dissertation highlights its objectives, focus, scope and …

    mcmaster Repository record for SYSTEM-LEVEL SEISMIC PERFORMANCE QUANTIFICATION OF REINFORCED MASONRY BUILDINGS WITH BOUNDARY ELEMENTS (opens in a new tab)

  18. Evaluación del desempeño y la vulnerabilidad sísmica de la I.E. Ramón Castilla debido a sismos de diseño en la localidad de Samanco – Ancash utilizando el análisis estático no lineal (AENL) y el modelo equivalente para albañilería confinada

    … En segundo lugar, bajo los lineamientos del ASCE 41-13, se asignó propiedades no lineales a los materiales y se elaboró la calibración de las rotulas plásticas a los elementos estructurales. Asimismo, se realizó el análisis estático no lineal de empuje incremental, conocido como pushover, …

    upc-peru Repository record for Evaluación del desempeño y la vulnerabilidad sísmica de la I.E. Ramón Castilla debido a sismos de diseño en la localidad de Samanco – Ancash utilizando el análisis estático no lineal (AENL) y el modelo equivalente para albañilería confinada (opens in a new tab)

Page 1 of 3