Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 24 for “"ASCE 7-10"”
-
REEVALUATION OF ASCE 7-10 EXTERNAL PRESSURE COEFFICIENTS ON THE COMPONENTS AND CLADDING OF LOW-RISE BUILDINGS USING MODERN WIND TUNNEL TESTING DATA
… of the American Society of Civil Engineers (ASCE 7). Portions of the current version, ASCE 7-10, rely on wind tunnel tests that date back 30-50 years. In recent decades, advances in computer technology have allowed the simultaneous recording of many more pressure taps than was possible …
-
Comparative Study of Seismic Performance of Reinforced Concrete Buildings designed in accordance with the Seismic Provisions of ASCE 7-10 and IS 1893-2002
… Seismic provisions of the current versions of ASCE 7 and IS 1893 are compared on the basis of the type of allowable analysis procedures, zoning system, site classification, fundamental time period of the structure, response reduction factor, importance factor, minimum design lateral force, …
-
Seismic Design of Reinforced Concrete Buildings Using Bangladesh National Building Code (BNBC 1993) and Comparison with Other Codes (ASCE 7-10 And IS 1893-2002)
… (BNBC-1993), India (IS-1893), and the U.S. (ASCE 7-10) in relation to analysis, design, and seismic performance of reinforced concrete buildings was done on the basis of the type of allowable analysis procedures, zoning system, site classification, fundamental vibration period of the …
-
Lateral Strength and Ductile Behavior of a Mortise-Tenon Connected Timber Frame
… of ductile racking while reliably complying with ASCE 7-10 building code drift speci! cations, implying an increase in the ASCE 7-10 ductility factor (R) for wood frames when used as lateral force resisting elements. A secondary goal was to promote traditional heavy timber framing as a main …
-
Control de irregularidad por torsión en una edificación de 12 pisos mediante el reforzamiento con disipadores de energía fluido viscosos
… del dispositivo bajo los códigos FEMA 273, 274 y ASCE 7-10.
-
Atmospheric Boundary Layer Processes To Mimic Peak Pressures on Low-Rise Buildings: CFD Versus Full-Scale and Wind Tunnel Measurements
… of the American Society of Civil Engineers (ASCE) 7-10 standard for external pressure coefficients, for roof components and cladding (C&C) design are also based on published wind tunnel data. Recent field measurements show significant deviation of full-scale pressures from wind tunnel …
-
Análisis y diseño estructural de un silo de concreto armado tipo cono invertido
… de Materiales Granulares »; y el estándar del ASCE: ASCE 7-10. Debido a las numerosas fallas ocurridas en este tipo de estructuras históricamente, dichas normativas y consideraciones se revisan y actualizan para mejorar su desempeño.
-
Wind Loads on Low-slope Roofs of Low-rise and Mid-rise Buildings with Large Plan Dimensions
… (118 m x 118 m) and different heights (5 m, 10 m, and 20 m). The models were tested in simulated open country and suburban exposures for 7 wind directions: 0°, 15°, 30°, 45°, 60°, 75° and 90°. The pressure measurements have been presented in terms of contours of enveloped pressure …
-
Damage prediction of low-rise buildings under hurricane winds
… horizontal dimension and less than 18.3 m in ASCE 7-10. They represent the majority of commercial, residential, and industrial buildings. Approximate 90% of the existing low-rise residential buildings are constructed as wood light-frame buildings that are not fully engineered and thus more …
-
Eccentrically braced steel frames as a seismic force resisting system
… The design process is from the AISC 341-10 Seismic Provisions for Structural Steel Buildings with the gravity and lateral loads calculated according to ASCE 7-10 Minimum Design Loads for Buildings and Other Structures. Seismic loads are calculated using the Equivalent Lateral Force …
-
Development of a Comprehensive Linear Response History Analysis Procedure for Seismic Load Analysis
… according to Chapter 16 of the American Standard ASCE 7-10. A careful analysis is presented about the selection of ground motions using real records and using artificial records generated such that their response spectrum matches with a defined target spectrum; three different techniques are …
-
Influencia del modelamiento en la respuesta estructural de muros cortina utilizando el método de los elementos finitos en edificios de 10, 20 y 30 pisos en la ciudad de Lima
… evaluó tres edificaciones de diferentes alturas, 10, 20 y 30 pisos ubicado en la ciudad de Lima, diseñado bajo las normas nacionales; se aplicó dos tipos de análisis, integral (junto a la estructura principal) y aislado (tipo parrilla). Para la modelación estructural de la estructura con y sin …
-
Experimental Seismic Evaluation of Ceiling-Piping-Partition Nonstructural Systems
… the recommended amplification suggested by the ASCE 7-10 code for flexible components.
-
Risk-Based Wind Loss and Mitigation for Residential Wood Framed Construction
… of one-story, single-family homes at each ASCE 7-10 wind contour through Monte Carlo simulation of local annual maximum wind speeds convolved with Hazus-MH economic loss functions for open terrain and non-open terrain. The results are integrated into a decision-making framework designed to …
-
Determination of rational tornado design wind speed for residential woodframe structures
… States. Wind analysis is performed using the ASCE 7-10 standard loading in combination with the existing literature which provides loading for a tornado on structures. Fragilities are developed for the main components along the vertical load path that included roof sheathing, roof-to-wall …
-
Wind pressures on flat roof edges and corners of large low buildings
… of common configurations. Large buildings, say 100 m long, have not been considered when these provisions were established. As a result, the interaction between wind and buildings of such geometries should be investigated for the assessment of current wind provisions in terms of their …
-
Design and structural testing of tall Hexcrete wind turbine towers
… (120 m) and 459 ft (140 m) for Siemens SWT 2.3-108 and SWT 3.2-113 turbines. A strength and design validation experimental test was performed on a full scale section of one of the 120 m towers in a laboratory setting and it was found that the Hexcrete tower design adequately met the required …
-
Preliminary Structural Optimization and Validation of Steel Purlins in Solar Canopies
A method for establishing external loads applied to a steel purlin in a solar panel canopy and calculating the resulting deflection, moment, and shear reactions is developed. The methodology is compliant with American Society of Civil Engineers, International Building Code, American Iron and Steel …
-
System Nonlinear Performance of Low-Rise Buildings under Database-Assisted Hurricane Loads
… and the adequacy of the wind design by using the ASCE 7-10 wind provisions on residential buildings is evaluated.
-
A Comparative Study on Seismic Analysis Methods and the Response of Systems with Classical and Nonclassical Damping
… Design Loads for Buildings and Other Structures (ASCE 7-10) and used for application of the Equivalent Lateral Force Procedure (ELFP) and Response Spectrum Analysis (RSA). When applying RSA, the modal peak responses were combined using the Absolute Sum (ABS), Square-Root-of-the-Sum-of-Squares …
Page 1 of 2