Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 36 for “"ASCE 7-16"”

  1. Precast concrete diaphragm design by ASCE 7-16

    … of diaphragms. Code provisions prior to the ASCE 7-16 determined diaphragm design forces based solely on the fundamental modal response of structures. However, further research proved that higher modes also influenced diaphragm forces. Therefore, a change was warranted to diaphragm design …

    ksu Repository record for Precast concrete diaphragm design by ASCE 7-16 (opens in a new tab)

  2. A Method for Conducting Push-over Tsunami Analysis in Accordance with ASCE 7-16

    … of Chapter 6 Tsunami Loads and Effects in ASCE 7-16 Minimum Design Loads and Associated Criteria for Buildings and Other Structures, significant analytical effort will soon be required of structural engineers to ensure that susceptible buildings are appropriately designed and detailed to …

    hawaii Repository record for A Method for Conducting Push-over Tsunami Analysis in Accordance with ASCE 7-16 (opens in a new tab)

  3. Flood-Entrained Debris Impacts on Structures: A Structural-Hydraulic Numerical Analysis

    … events. The American Society of Civil Engineers (ASCE) released Chapter 6 of ASCE 7-16, which was the world's first standard that addressed tsunami resilient design prescriptions in mandatory language. Chapter 6 of ASCE 7-16 classifies tsunami loads into three categories: (1) Hydrostatic loads; …

    ottawa-retro Repository record for Flood-Entrained Debris Impacts on Structures: A Structural-Hydraulic Numerical Analysis (opens in a new tab)

  4. Sensitivity of Steel Purlins to Changes in Application of Wind Loads

    … obtained using the wind design provisions in ASCE 7-16 Chapter 30 for Components and Cladding. The primary data of interest was shear and moment values along the length of the purlins, which were modeled as continuous beams. Comparisons were made between the resultant shear and moment from …

    vt Repository record for Sensitivity of Steel Purlins to Changes in Application of Wind Loads (opens in a new tab)

  5. Burgulu yüksek yapıların yanal yükler altında davranışlarının incelenmesi

    … ve devrilme momentleri incelenmiştir. Çalışmada, ASCE 7-16 yönetmeliğinden yararlanılmıştır. Döşemeler tam rijit diyafram olarak atanmıştır. Kolonlar betonarme olarak ve yapının merkezinde bulunan perdeler kompozit olarak modellenmiştir. Perde uç bölgelerinde bulunan betona gömülü I çelik …

    ogu-tr Repository record for Burgulu yüksek yapıların yanal yükler altında davranışlarının incelenmesi (opens in a new tab)

  6. Frequency Effect on Peak Pressure Coefficients Using the Narrowband Synthesis Random Flow Generator (NSRFG) Method

    … in the design of buildings and other structures. ASCE 7-16 is the manual used for the design of these buildings and other structures throughout the country. These design criteria have been approved based on research projects involving experimental procedures. For the design of wind loads, ASCE …

    arkansas Repository record for Frequency Effect on Peak Pressure Coefficients Using the Narrowband Synthesis Random Flow Generator (NSRFG) Method (opens in a new tab)

  7. Modelamiento de un hospital con aislador núcleo de plomo (LRB)

    … está formulada bajo las pautas del código ASCE 7-16 y SISCF. La investigación está validada por modelos informáticos de hospitales aislados, en lo que se detallara el modelamiento y las propiedades correspondientes del aislador núcleo de plomo, mejorando así su rendimiento sísmico. Los …

    upc-peru Repository record for Modelamiento de un hospital con aislador núcleo de plomo (LRB) (opens in a new tab)

  8. Wind Loads on Low-slope Roofs of Low-rise and Mid-rise Buildings with Large Plan Dimensions

    … peak pressure coefficients recommended by ASCE 7-16 for low-slope roofs of low-rise buildings are much higher than the experimental findings and using those recommended by ASCE 7-10 is safe and more economical for large low-rise buildings. Also, for buildings of 8 m height or more, the …

    concordia

  9. Modular Steel Frame for Residential Use

    … namely the International Building Code, ASCE 7-16, and the American Iron and Steel Institute. In designing with cold formed steel, the team hoped to create a reliable and resilient structure that could be erected efficiently and serve several different purposes, including disaster relief …

    santa-clara Repository record for Modular Steel Frame for Residential Use (opens in a new tab)

  10. Effects of Flow Shielding and Channeling on Tsunami-Induced Loading of Coastal Structures

    … which improves upon the methods provided in the ASCE 7-16 design provisions used to estimate force amplifications due to neighboring structures.

    washington Repository record for Effects of Flow Shielding and Channeling on Tsunami-Induced Loading of Coastal Structures (opens in a new tab)

  11. Experimental Study of Tornado-Induced Pressures

    … The comparison with the recently modified ASCE 7-16 code showed that roof corner pressures are safely predicted for all the cases while the mid-roof zone and the middle of the walls experienced higher suctions exceeding the recommended wind loads in ASCE 7-16.

    uwo Repository record for Experimental Study of Tornado-Induced Pressures (opens in a new tab)

  12. Warehouse Design for Automotive Parts Manufacturers in Bekasi, Indonesia

    … National Standards, which is adopted mostly from ASCE 7-16, ACI 318-14, and AISC 360-16. The design of the superstructure involved the design of the columns, beams, slabs, and rafters of the structure. The structural design incorporated seismic design requirements according to the Indonesian …

    santa-clara Repository record for Warehouse Design for Automotive Parts Manufacturers in Bekasi, Indonesia (opens in a new tab)

  13. An Exploration into Tornado Resistant Residential CLT Structures

    … analytical approaches in conjunction with ASCE 7-16, NDS 15, and PRG-320, this research hopes to lay groundwork for future research into the feasibility of such a house design at larger sizes and faster tornadoes. Because it is rather difficult to test experimentally how these structures …

    clemson Repository record for An Exploration into Tornado Resistant Residential CLT Structures (opens in a new tab)

  14. Factores de importancia para el diseño de aisladores sísmicos para una edificación multifamiliar de concreto armado con diferentes alturas en Lima, Perú

    … de diferentes países (NTP E.031, NCh 2745, ASCE 7-16 y NZS 1170.5). Para poder identificar los factores de mayor importancia en un diseño de aislador. Finalmente, se realiza la comparación de las derivas, desplazamientos y aceleraciones.

    upc-peru Repository record for Factores de importancia para el diseño de aisladores sísmicos para una edificación multifamiliar de concreto armado con diferentes alturas en Lima, Perú (opens in a new tab)

  15. Malley Recreational Center Redesign

    … connections, all designed in accordance with ASCE 7-16, NDS 2024, and CBC 2021. The report findings confirm that the proposed expansion is structurally sound, geotechnically feasible, and that mass timber is a viable and sustainable structural material for this application. This report is …

    santa-clara Repository record for Malley Recreational Center Redesign (opens in a new tab)

  16. Evaluación del coeficiente de disipación de energía R en edificaciones de concreto reforzado con disipadores de energía viscosos ubicados en zona de amenaza sísmica alta

    … out in different structures heights: 4, 8, 12, 16 and 20 floors. The analysis and design of the buildings was carried out in accordance with the NSR-10 regulations and the parameters for structures with energy dissipation systems included in the ASCE 7-16 document. The R coefficient is …

    un-colombia Repository record for Evaluación del coeficiente de disipación de energía R en edificaciones de concreto reforzado con disipadores de energía viscosos ubicados en zona de amenaza sísmica alta (opens in a new tab)

  17. Evaluación del reforzamiento estructural implementando disipadores sísmicos BRB y ADAS para una edificación de siete pisos

    … criterios establecidos por la Norma E.030 y la ASCE 7-16. Asimismo, se determinaron parámetros de respuesta estructural como derivas de entrepiso, cortante basal, desplazamientos laterales, irregularidad torsional, capacidad de disipación de energía y niveles de desempeño. Los resultados …

    upc-peru Repository record for Evaluación del reforzamiento estructural implementando disipadores sísmicos BRB y ADAS para una edificación de siete pisos (opens in a new tab)

  18. Análisis y diseño estructural de vigas, columnas y muros de concreto armado de una vivienda multifamiliar de 6 niveles en Jesús María con el uso de normas americanas y peruanas

    … en las diferentes normativas E.030 y ASCE 7-16, empleando procesos específicos para cada caso. En cuanto al diseño de concreto armado, este se rigió en base a las normativas E.060 y ACI-318, con la finalidad de identificar las diferencias de diseño más notables en vigas, placas y …

    upc-peru Repository record for Análisis y diseño estructural de vigas, columnas y muros de concreto armado de una vivienda multifamiliar de 6 niveles en Jesús María con el uso de normas americanas y peruanas (opens in a new tab)

  19. Characterizing the Load-Deformation Behavior of Steel Deck Diaphragms using Past Test Data

    … A new alternative diaphragm design procedure in ASCE 7-16 increases diaphragm seismic demand to better represent expected demands. The resulting elastic design forces from this method are reduced by a diaphragm design force reduction factor, Rs, to account for the ductility of the diaphragm …

    vt Repository record for Characterizing the Load-Deformation Behavior of Steel Deck Diaphragms using Past Test Data (opens in a new tab)

Page 1 of 2