Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 284 for “"ASHRAE"”.
-
Avaliação do conforto térmico de uma biblioteca universitária pela ASHRAE Standard 55 e EN 15251
… de conforto higrotérmico entre as normas ANSI/ASHRAE Standard 55 e EN 15251, tendo como estudo de caso a Biblioteca Central da Universidade Federal de Viçosa-MG, apontando as diferenças entre os seus resultados. A pesquisa foi realizada em quatro etapas principais: a realização de medições in …
-
Fluctuations in ASHRAE Refrigerant Physical Properties and the Effect on Single and Two Phase Flow
… values are compared to 2013, the most recent ASHRAE Handbook edition, as well as between editions beginning in 1981 in a standard percent change format. It is seen that physical properties can vary by nearly 30% with respect to edition 2013 and up to 25% between editions with a stabilizing …
-
Methodology for Rating a Building's Overall Performance based on the ASHRAE/CIBSE/USGBC Performance Measurement Protocols for Commercial Buildings
… Refrigerating and Air-Conditioning Engineers (ASHRAE)/Chartered Institute of Building Services Engineers (CIBSE)/United States Green Building Council (USGBC) Performance Measurement Protocols (PMP) for Commercial Buildings in a case-study office building in central Texas. As the first …
-
Determining Pressure Losses For Airflow In Residential Ductwork
… study. The testing was done in compliance with ASHRAE Standard 120-1999, Methods of Testing to Determine Flow Resistance of HVAC Air Ducts and Fittings (ASHRAE 1999). Duct sizes of 6", 8", and 10" were tested in a positive pressure, blow-through configuration. An As-Built Test Protocol expands …
-
Investigation of standard test procedures for integral storage solar domestic hot water systems
… collector, so that a standard test similar to ASHRAE Standard 93-77 might reasonably be used to obtain the performance characteristics of the collection element of these systems. The results of an ASHRAE 93-77 type test might then be used to obtain performance ratings under ASHRAE Standard 95 …
-
Exploring Energy, Comfort, and Building Health Impacts of Deep Setback and Normal Occupancy Smart Thermostat Implementation
… the ventilation and temperature requirements of ASHRAE 90.2-2013. Custom weather models and occupancy schedules were generated to efficiently explore a combination of weather conditions, building constructions, and occupancy states. The custom modeling approach was combined with previous …
-
Whole-house mechanical ventilation in a mixed-humid climate
… within homes with poor outdoor air ventilation. ASHRAE Standard 62.2 quantifies the amount of whole-house ventilation required based on the number of occupants and the square footage of conditioned space, but leaves the design of the ventilation system up to the mechanical engineer or HVAC …
-
Experimental Investigation of Reflection of Airborne Noise at Duct Terminations
… Refrigerating, and Air-Conditioning Engineers (ASHRAE) Handbook lists values of end reflection loss (ERL), a frequency dependent parameter describing energy reflected back up a duct at a termination impedance, to help engineers design and account for noise. The ASHRAE Handbook does not account …
-
Analysis of acoustics in heating, ventilation and air conditioning systems
… systems is presented. The objective of this ASHRAE funded (ASHRAE TRP 556) project was to present the HVAC designer with a set of algorithms for determining the acoustical characteristics of heating, ventilation and air conditioning systems that are useful and reliable. All algorithms are …
-
Physical Modeling of the downwash effect of rooftop structures on plume dispersion
… face. The minimum dilution models recommended by ASHRAE (2003, 2007) as well as the ASHRAE Geometric Stack Design Method (AGM) were evaluated. It was found that the ASHRAE models do not account for the downwash effect of the RTS on plumes and result in either overly conservative or un-conservative …
-
An Investigation of Alternative Methods for Measuring Static Pressure of Unitary Air Conditioners and Heat Pumps
… air-conditioning and heat pumps. Specifically, ASHRAE Standard 37, the industry standard for test setup, requires an outlet duct of a certain length, based on the unit outlet geometry, and this ducting added to the unit height may result in a test apparatus height that exceeds psychometric test …
-
A knowledge-based system for HVAC system type selection
… Refrigerating and Air-Conditioning Engineers (ASHRAE), Inc. aimed at assembling, developing, and verifying a knowledge-based system (KBS) for the selection of a heating, ventilating; and air conditioning (HVAC) system type for small (less than 20~000 ft2) office buildings. "The work includes …
-
Methodology to Develop and Test an Easy-to-use Procedure for the Preliminary Selection of High-performance Systems for Office Buildings in Hot and Humid Climates
… model was then further modified based on the ASHRAE Standard 90.1-1999 commercial building energy code. A code-compliant (ASHRAE Standard 90.1-1999) SGDOE-2.1e simulation model was then used as a baseline for the evaluation of the high-performance measures. A total of 14 high-performance …
-
Performance-Based Framework for Assessing Thermal Comfort Conditions at the HUB on the University of Washington Campus
… human health. Building heating and cooling (ASHRAE) standards exist to regulate commercial building indoor temperature and ventilation requirements; however, it is unclear if current standards are reliable, or if the standards should be revised to better optimize occupant comfort and building …
-
Integrated demand control ventilation for single duct VAV system with terminal reheat
… amount of outdoor air into the space as needed. ASHRAE 62.1 standard recommends the ventilation rate required for a space to protect public health. Thus, the study of DCV has to comply with ASHRAE standard or other similar standards. Considering that the standard is updated every few years, the …
-
Acoustic breakout from fiberglass ducts
… Ventilation, and Air Conditioning Engineers (ASHRAE); Recent advances in manufacturing techniques have led to the development of fiberglass lined sheet metal ducts, and ducts made from fiberglass ductboard. The equations presented by ASHRAE do not accurately predict the transmission loss from …
-
Wind-induced dispersion of building exhaust in an urban environment : a full-scale and wind-tunnel study
… is to evaluate the exhaust dispersion using ASHRAE dispersion models. As another alternative, a wind tunnel study can be carried out to predict peak concentrations at critical locations. However, neither ASHRAE models nor wind tunnel modeling have been thoroughly validated with full-scale …
-
Indoor Air Quality: Determination of VOC's in a Reproductive Clinic.
… Refrigeration, and Air Conditioning Engineers (ASHRAE). Recommendations include assessing air intakes to assure dampers are adjusted to allow 15 ft3/min/person of fresh air established by ASHRAE.
-
Análise do impacto do sombreamento vegetal no conforto termo-luminoso em edificações no clima quente e úmido
… do método de conforto adaptativo indicado pela ASHRAE Standard 55 (ASHRAE, 2010), classificação do nível de eficiência energética do Regulamento Técnico da Qualidade para o Nível de Eficiência Energética de Edificações Residenciais (RTQ-R), resultados de Daylight autonomy (DA) e uniformidade da …
Page 1 of 15