Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 14 of 14 for “"ASTM A1035"”

  1. Shear Behaviour of Concrete Slabs and Beams Reinforced with High-Performance ASTM A1035 Steel

    … steel bars manufactured to conform to ASTM A1035-11 have different metallurgy and microstructure than conventional reinforcing steel. These changes result in an effective yield strength significantly higher than conventional ASTM A615 steel while also being less susceptible to …

    alberta Repository record for Shear Behaviour of Concrete Slabs and Beams Reinforced with High-Performance ASTM A1035 Steel (opens in a new tab)

  2. Performance-based seismic design and assessment of concrete bridge piers reinforced with high-strength steel rebar

    … thereby make appropriate design recommendations. ASTM A1035 Grade 690 steel was the primary focus of this study, however, other types of HSS were also considered in a number of assessments for comparison purposes. In this study, a comprehensive analytical program with an overarching objective of …

    ubc Repository record for Performance-based seismic design and assessment of concrete bridge piers reinforced with high-strength steel rebar (opens in a new tab)

  3. Static and Blast Performance of Reinforced Concrete Beams Built with High-Strength Steel and Stainless Steel Reinforcement

    High-strength steel (HSS) conforming to ASTM A1035 is becoming increasingly used in various structural applications, including in high-rise buildings and bridges. Due to their chemistry and manufacturing process, ASTM A1035 steel bars result in a combination of high tensile strength to yield ratio …

    ottawa-retro Repository record for Static and Blast Performance of Reinforced Concrete Beams Built with High-Strength Steel and Stainless Steel Reinforcement (opens in a new tab)

  4. Flexural Strength, Ductility, and Serviceability of Beams that Contain High-Strength Steel Reinforcement and High-Grade Concrete

    … Also, ACI ITG-6, "Design Guide for the Use of ASTM A1035 Grade 100 Steel Bars for Structural Concrete" and NCHRP Report 679, "Design of Concrete Structures Using High-Strength Steel Reinforcement" have made progress towards identifying how code provisions in ACI 318 and AASHTO could be changed …

    portland-state Repository record for Flexural Strength, Ductility, and Serviceability of Beams that Contain High-Strength Steel Reinforcement and High-Grade Concrete (opens in a new tab)

  5. Structural Concrete Design with High-Strength Steel Reinforcement

    … experimental phase of this study is the use of ASTM A1035 reinforcing steel since it captures both behavioral aspects of interest, i.e., high-strength and no yield point. Three facets of reinforced concrete design are examined: flexural behavior in which A1035 steel is used as longitudinal …

    ohiolink Repository record for Structural Concrete Design with High-Strength Steel Reinforcement (opens in a new tab)

  6. PERFORMANCE EVALUATION OF CORROSION PROTECTION SYSTEMS FOR REINFORCED CONCRETE

    … steel, MMFX steel containing 9% and 4% chromium (ASTM A1035 Type CS and CM steel), and epoxy-coated MMFX steel containing 4% and 2% chromium (epoxy-coated ASTM A1035 Type CM and CL steel). Furthermore, corrosion performance of reinforced concrete with partial replacement of cement by 20% fly ash, …

    ku Repository record for PERFORMANCE EVALUATION OF CORROSION PROTECTION SYSTEMS FOR REINFORCED CONCRETE (opens in a new tab)

  7. Behaviour of Concrete Shear Walls Reinforced with High-Strength Reinforcement Under Reversed Cyclic Loading

    … and reinforced with Grade 690 MPa (ASTM A1035) reinforcement were constructed and tested under constant axial compression and cyclic load reversals. The walls were ¼ -scale representations of a 6-storey shear wall with height-to-length aspect ratios of 3.0 and 2.0. Test results show …

    ottawa-retro Repository record for Behaviour of Concrete Shear Walls Reinforced with High-Strength Reinforcement Under Reversed Cyclic Loading (opens in a new tab)

  8. Seismic response of circular concrete columns reinforced with CSA G30.18 500W steel

    … with columns reinforced with regular steel ASTM A706 Grade 420. Moreover, the strain limits for performance-based design (PBD) of bridges utilizing CSA G30.18 500W were derived from the measured material strain limits. Lastly, a comparative study of the seismic performance of bridge piers …

    ubc Repository record for Seismic response of circular concrete columns reinforced with CSA G30.18 500W steel (opens in a new tab)

  9. Analytical Evaluation of Structural Concrete Members with High-Strength Steel Reinforcement

    … studies. Steel reinforcement considered includes ASTM A1035, A955 (stainless steel), A706, A496, and A82. Analyses considered include material testing and characterization of each steel type for various sizes of reinforcing bar; the calculation of flexural capacities using an elastic-perfectly …

    ohiolink Repository record for Analytical Evaluation of Structural Concrete Members with High-Strength Steel Reinforcement (opens in a new tab)

  10. Blast Performance of Reiforced Concrete Beams Constructed with High-Strength Concrete and High-Strength Reinforcement

    … steel fibres, and reinforced with high strength ASTM A1035 bars are tested under simulated blast loading using the University of Ottawa shock-tube, with an additional 3 companion beams tested under quasi-static loading. The variables considered in this study include: concrete type, fibre content, …

    ottawa-retro Repository record for Blast Performance of Reiforced Concrete Beams Constructed with High-Strength Concrete and High-Strength Reinforcement (opens in a new tab)

  11. EVALUATION OF MULTIPLE CORROSION PROTECTION SYSTEMS FOR REINFORCED CONCRETE BRIDGE DECKS

    … the corrosion resistance of epoxy-coated (ASTM A775), hot-dip galvanized (ASTM A767), and continuously galvanized (ASTM A1094) reinforcement, and the conventional reinforcement (ASTM A615) used to produce them, as well as ChromX reinforcement (ASTM A1035 Type CS) under the rapid macrocell, …

    ku Repository record for EVALUATION OF MULTIPLE CORROSION PROTECTION SYSTEMS FOR REINFORCED CONCRETE BRIDGE DECKS (opens in a new tab)

  12. Seismic Performance of Reinforced Concrete Tall Buildings with Advanced Materials

    … conventional steel Grade 60, high strength ASTM A706 Grade 80, and high strength ASTM A1035 Grade 100 and 120. The response parameters were evaluated with the acceptance criteria of the Tall Building Initiative, TBI guidelines. Depending on the results, all cases with different grades …

    tamu Repository record for Seismic Performance of Reinforced Concrete Tall Buildings with Advanced Materials (opens in a new tab)

  13. Performance of Reinforced Concrete Bridge Columns with Various Reinforcement Details Subject to Long-Duration Earthquakes

    … specimens designed using conventional Grade 60 ASTM 706 reinforcing bars and tested under a sequence of long duration earthquakes (Tohoku, Japan 2011 EQ). All three columns had same longitudinal reinforcement ratio. However, the second column had different confinement spacing ratio compared to …

    unr Repository record for Performance of Reinforced Concrete Bridge Columns with Various Reinforcement Details Subject to Long-Duration Earthquakes (opens in a new tab)

  14. SFRC Slabs Longitudinally Reinforced with High Strength Steel

    Combining steel fiber reinforced concrete (SFRC) and high strength longitudinal reinforcement in a structural member creates the potential for increased strength and durability compared to conventional reinforced concrete members. There is however limited research into the structural behaviour of …

    alberta Repository record for SFRC Slabs Longitudinally Reinforced with High Strength Steel (opens in a new tab)