Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 10 of 10 for “"ASTM C457"”.

  1. Advances in measuring parameters of the air-void system in hardened concrete

    … system in hardened concrete is detailed in ASTM C457 “Standard Test Method for Microscopical Determination of Parameters of the Air-Void System in Hardened Concrete.” Microscopical methods are used to determine traverse lengths of air voids, aggregates, and pastes on the polished surface of …

    uiuc Repository record for Advances in measuring parameters of the air-void system in hardened concrete (opens in a new tab)

  2. Analysis of air-void system in hardened concrete from a three-dimensional perspective

    … from pressure exerted by freezing water. ASTM C457 “Standard Test Method for Microscopical Determination of Parameters of the Air-Void System in Hardened Concrete” is widely used for measuring the air void system. This manually conducted measurement is tedious and time-consuming, so …

    uiuc Repository record for Analysis of air-void system in hardened concrete from a three-dimensional perspective (opens in a new tab)

  3. Determining the Air Void Parameters of Concrete Using Digital Image Analysis of Polarized Light Micrographs

    The ASTM C457 test has long been a standard used to obtain the air void parameters of concrete materials. These air void parameters provide valuable information that has been linked to the performance of concrete under conditions such as freezing and thawing cycles. The standard test procedure …

    vt Repository record for Determining the Air Void Parameters of Concrete Using Digital Image Analysis of Polarized Light Micrographs (opens in a new tab)

  4. Developing An Alternative Hardened Concrete Air Void Characterization Method

    … air void system in concrete. This study uses ASTM C457, “Standard Test Method for Microscopical Determination of Parameters of the Air-Void System in Hardened Concrete” as a baseline characterization method and attempts to thoroughly reduce the long sample preparation and characterization time …

    texas-state Repository record for Developing An Alternative Hardened Concrete Air Void Characterization Method (opens in a new tab)

  5. Three-dimensional Segmentation of Air-void System in Hardened Concrete using Photometric Stereo and Artificial Intelligence Methods

    … petrographic test, which is specified in ASTM C457, is the standard test procedure for characterizing the air-void system and evaluating the freeze-thaw performance of hardened concrete samples. Specifically, the linear-traverse method (Procedure A) and the modified point-count method …

    texas-state Repository record for Three-dimensional Segmentation of Air-void System in Hardened Concrete using Photometric Stereo and Artificial Intelligence Methods (opens in a new tab)

  6. A study of self consolidating concrete for cast in place applications: Current practices, rapid wcm determination, and stability effects of pumping

    … Of the specimens analyzed, half did not meet the ASTM C457 recommended value for specific surface to resist moderate freeze-thaw cycling while none of the samples met the ASTM C457 recommendation of spacing factor less than 0.20 mm for structures exposed to moderate freeze-thaw conditions. …

    wvu Repository record for A study of self consolidating concrete for cast in place applications: Current practices, rapid wcm determination, and stability effects of pumping (opens in a new tab)

  7. An Investigation of the Effect of Performance Engineered Mixture (PEM) Design on Durability and Air Void Matrix of Concrete Pavements

    … was evaluated by collecting a SAM number, ASTM C666 freeze/thaw test prisms, and a prism to conduct ASTM C457 spacing factor analysis. It was found that cement content in portland cement concrete pavement (PCCP) could be reduced to 440 pounds per cubic yard while maintaining strength, …

    arkansas Repository record for An Investigation of the Effect of Performance Engineered Mixture (PEM) Design on Durability and Air Void Matrix of Concrete Pavements (opens in a new tab)

  8. Characterization of multiscale porosity in cement-based materials: effects of flaw morphology on material response across size and time scales

    … commonly utilized in practiced, and specified in ASTM C457, as a measure of concrete's ability to resist to damage under cyclic freeze/thaw loading. This has the potential to improve economy by improving the quality of petrographic assessment and reducing the need for more expensive and …

    gatech Repository record for Characterization of multiscale porosity in cement-based materials: effects of flaw morphology on material response across size and time scales (opens in a new tab)

  9. Microstructure characterization of foamed cement and concrete

    … the hardened air-void parameters prescribed by ASTM C457 were also estimated using an automated flatbed scanner method. There was no significant change in the spacing factors of the concrete mixtures subjected to vibration, indicating the robustness of the air-void system. The results also …

    uiuc Repository record for Microstructure characterization of foamed cement and concrete (opens in a new tab)

  10. EFFECT OF CRACK-REDUCING TECHNOLOGIES AND SUPPLEMENTARY CEMENTITIOUS MATERIALS ON SETTLEMENT CRACKING OF PLASTIC CONCRETE AND DURABILITY PERFORMANCE OF HARDENED CONCRETE

    … materials on freeze-thaw durability, based on ASTM C666 Procedure B, scaling resistance, based on a modified version of Canadian Test BNQ NQ 2621-900 Annex B, and characteristics of the air-void system, obtained following ASTM C457. The research also examined the correlation between air-void …

    ku Repository record for EFFECT OF CRACK-REDUCING TECHNOLOGIES AND SUPPLEMENTARY CEMENTITIOUS MATERIALS ON SETTLEMENT CRACKING OF PLASTIC CONCRETE AND DURABILITY PERFORMANCE OF HARDENED CONCRETE (opens in a new tab)