  1. The Tissue-reduced Virtual Family Models for RF-induced Heating Evaluation of Passive Medical Implants at 1.5 T and 3 T

    … for the safety of patients. The study in ASTM phantom and human models is adopted to evaluate the RF-induced heating near the medical implants. To make the experiment in human models more practical, the tissue-reduced virtual family models were proposed for RF-induced heating simulation …

    houston Repository record for The Tissue-reduced Virtual Family Models for RF-induced Heating Evaluation of Passive Medical Implants at 1.5 T and 3 T (opens in a new tab)

  2. Methods and Strategies for Evaluating MRI Rf-Induced Heating for Implanted Metallic Stents

    … the American Society for Testing and Materials (ASTM) phantom. Experimental measurements are conducted for validation. Then four search strategies are introduced for assessing the worst-case RF-induced heating based on the simulated results of the multi-configuration devices, and a stent is …

    houston Repository record for Methods and Strategies for Evaluating MRI Rf-Induced Heating for Implanted Metallic Stents (opens in a new tab)

  3. MRI Safety Concerns: Anatomy Impacts on Radiofrequency Induced Heating and Implant Impacts on Gradient Induced Peripheral Nerve Stimulation

    … the posture impacts are studied, and a new phantom is proposed to evaluate the RF-induced heating more accurately compared with the standard American Society for Testing and Materials (ASTM) phantom. Based on the results and conclusions, a lot of guidance and suggestions are provided to …

    houston Repository record for MRI Safety Concerns: Anatomy Impacts on Radiofrequency Induced Heating and Implant Impacts on Gradient Induced Peripheral Nerve Stimulation (opens in a new tab)

  4. Model Validation and Inversion of Active Implantable Medical Devices

    … using a few direct measurements inside the ASTM phantom. Folded orthogonal pathways based on the Hadamard matrix are used in the model development to make the problem of the AIMD model development to be well-conditioned. Both induced voltage and heating models for the example AIMDs were …

    houston Repository record for Model Validation and Inversion of Active Implantable Medical Devices (opens in a new tab)

  5. A Feasible Method to Evaluate RF-Induced Heating Behavior of Passive Orthopedic Implants in Human Body

    … heating in a standard and fully controlled phantom, which is filled with a homogeneous media to mimic the human body tissues. However, the RF-induced heating in a homogeneous regular shaped media is different from that in a heterogeneous human body, especially patients with orthopedic …

    houston Repository record for A Feasible Method to Evaluate RF-Induced Heating Behavior of Passive Orthopedic Implants in Human Body (opens in a new tab)

  6. Simulated and experimental approaches to the development of novel test phantoms for radiofrequency heating of implanted medical devices

    … nature of the current RF heating test (ASTM F2182-19a). In this thesis, novel test platforms are presented for more realistic evaluation of RF heating in orthopedic IMDs, which were used to experimentally challenge the behavior of their simulated counterparts. These test platforms were …

    uwo Repository record for Simulated and experimental approaches to the development of novel test phantoms for radiofrequency heating of implanted medical devices (opens in a new tab)

  7. Radiofrequency Induced Heating of Implanted Stereo-electroencephalography Electrodes During MRI Scan: Theory, Measurements and Simulations

    … insulated conducting copper wire using an MRI phantom. The benchmark for characterizing the level of RF heating was the temperature rise within the phantom and near the implants. These studies were then extended to include an 8 contact SEEG electrode, and then configurations with multiple wires …