Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 69 for “"Absolute Calibration"”.
-
Absolute calibration of a retarding-potential Mott polarimeter
… eff}$, which must be determined through calibration. This work describes a novel technique for calibrating a Mott polarimeter that makes use of electrons of accurately known polarization obtained through Penning ionization reactions involving electron spin polarized He(2$\sp3$S) …
-
Evaluation of Absolute Calibration of Multi-Filter Rotating Shadowband Radiometer
The focus of this thesis is to evaluate the absolute calibration of a Multi[1]filter Rotating Shadowband Radiometer (MFR-7) by comparing the measured solar irradiance to the standard solar irradiance at the top of the atmosphere. Four MFR-7s were simultaneously set up to collect actual data at …
-
Empirical Absolute Calibration Model for Multiple Pseudo-Invariant Calibration Sites
This work extends an empirical absolute calibration model initially developed for the Libya 4 Pseudo-Invariant Calibration Site (PICS) to five additional Saharan Desert PICS (Egypt 1, Libya 1, Niger 1, Niger 2, and Sudan 1), and demonstrates the efficacy of the resulting models at predicting sensor …
-
Hyperspectral Empirical Absolute Calibration Model Using Libya 4 Pseudo-Invariant Calibration Site
… this paper is to find an empirical hyperspectral absolute calibration model using Libya 4 pseudo-invariant calibration site (PICS). The approach involves using the Landsat 8 (L8) Operational Land Imager (OLI) as the reference radiometer and using Earth Observing One (EO-1) Hyperion, with a …
-
Absolute calibration techniques for UV spectroscopy based upon platinum emission line spectra
… project was tasked with performing wavelength calibration as part of the ongoing development of the Naval Postgraduate Schoolαs Lineate Imaging Near Ultraviolet Spectrometer (LINUS). This calibration was necessary for the ability of LINUS to detect, to classify, and to quantify several …
-
In-flight absolute calibration of radiometric sensors over dark targets using vicarious methods
The ability to conduct in-flight, absolute radiometric calibrations of ocean color sensors will determine their usefulness in the decade to come. On-board calibration systems are often integrated into the overall design of such sensors and have claimed uncertainty levels below 5%. Independent means …
-
Environmental gamma-ray spectrometry: simulation of absolute calibration of in-situ and airborne spectrometers for natural and anthropogenic sources
… theoretically a range of problems encountered in calibration of -ray spectrometers (converting count rates to radioelement ground concentrations), for the natural and manmade radionuclides. For in-situ and aerial survey measurements, the form of radionuclide deposition with soil depth, aerial …
-
The Development of Dark Hyperspectral Absolute Calibration Model Using Extended Pseudo Invariant Calibration Sites at a Global Scale: Dark EPICS-Global
… aimed to develop a novel dark hyperspectral absolute calibration (DAHAC) model using stable dark targets of "Global Cluster - 36" (GC-36), one of the clusters from "300 Class Global Classification." The stable dark sites were identified from GC-36 called "Dark EPICS-Global" covering the …
-
Absolute Calibration of an Infrared Detector to Monitor Oxygen Singlet Delta Concentrations Using the No-O Glow as a Chemiluminescent Standard
Made available in DSpace on 2017-07-06T18:56:20Z (GMT). No. of bitstreams: 2 Shannon_David_C_MS.pdf: 37340707 bytes, checksum: f7f2ecdf2d7730d09bfbdf23d71ef940 (MD5) license.txt: 4813 bytes, checksum: 715c4321821a960fa1a1e91d2ac7ebce (MD5) Previous issue date: 1984
-
Evaluation of flash and fluorescent sources with respect to recommended ocular exposure thresholds
… of a diode array radiometer calibrated for absolute radiometric measurements and software for the application of the currently accepted threshold limits for exposure to the various wavelengths of radiation. Absolute calibration of the array radiometer was accomplished to within 3 percent of …
-
Consistent Radiometric Calibration of Landsat-1 Through -5 MSS Sensors Using Pseudo-Invariant Calibration Sites
… of this project was to establish a cross-calibration connection from the Landsat-5 MSS back to the Landsat-I MSS in order to consistently calibrate the entire MSS data in the USGS archive. First, the lifetime radiometric stability of all five MSS sensors was studied using the Sonoran …
-
Automated Pseudo-Invariant Calibration Site Selection Using Temporal Statistics
… the best regions for satellite sensor cross calibration. These regions, commonly referred to as pseudo-invariant calibration sites (PICS), typically are located in arid regions where no significant temporal and spatial changes occur over long periods of time. Over the past several years, the …
-
Απόδοση ατμοσφαιρικού φθορισμού κοσμικών ακτίνων υπερυψηλών ενεργειών: Φαινομενολογία και πειραματική μελέτη
… appropriate instrumentation for the relative and absolute calibration of AFY in accelerator electron beams. A special prototype experimental setup of a stigmatic high-resolution UV spectrograph has been developed in the High Energy Laboratory. This setup gave us the possibility to study and test …
-
An Updated Radiometric Calibration of the Hyperion Sensor
… the EO-1 Hyperion, by first performing cross calibration with a multispectral sensor, the Landsat 7 ETM+, and then absolute radiometric calibration using the reflectance based approach of vicarious calibration. The test site used for the characterization of the Hyperion sensor is a region …
-
Modified Gold-Coated Magnetic Nanoparticles: Development of an Amperometric Calibration-Free Metal-Ion Sensor
… several milestones in the development of an absolute calibration-free sensor are described, using a sensing interface of modified, gold-coated magnetic nanoparticles (Au@Fe3O4). The Au@Fe3O4 sensing interface is comprised of a self-assembled monolayer of thioctic acid, whose distal end is …
-
Two-color pyrometer measurement of stainless steels due to relativistic electron beam heating in VHV/UHV environments
… stainless steel anode without the need for an absolute calibration a two-color pyrometer has been implemented. Using the ratio between two IR passbands along with two separate photodetectors a temperature vs. time graph can be plotted based upon Planck’s blackbody radiation law. Overall, an …
-
Spectroscopic Measurements of Natural and Artificial Light Sources
… measurements from the discharge. Finally, an absolute calibration technique for our spectroscopic system is presented.
-
IMPLOSION DYNAMICS, RADIATION CHARACTERISTICS, AND SPECTROSCOPIC MEASUREMENTS OF WIRE-ARRAY Z-PINCHES ON THE CORNELL BEAM RESEARCH ACCELERATOR (COBRA)
… electron density from the continuum data, an absolute calibration of the detection system was required. The details of these experiments, and the absolute calibration technique are presented.
-
THE ABSOLUTE RADIOMETRIC CALIBRATION OF SPACE-BASED SENSORS.
The need for absolute radiometric calibration of space-based sensors will continue to increase as new generations of space sensors are developed. A reflectance-based in-flight calibration procedure is used to determine the radiance reaching the entrance pupil of the sensor. This procedure uses …
-
Reciprocity calibration in a compliant cylindrical tube
A new method for absolute calibration of electroacoustic transducers is described which permits low frequency reciprocity calibration in a test apparatus of small dimensions. The method takes advantage of the reduced wave speed in a cylindrical water column bounded by a compliant PVC tube to reduce …