Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 52 for “"Absorption contrast"”

  1. High-Resolution Label Free Imaging of Endogenous Chromophore via Non-Linear Photoacoustic Microscopy

    … Current technologies for subcellular absorption contrast imaging, such as fluorescence confocal microscopy, require exogenous contrast agents to gain access to relevant biomolecules. All non-fluorescing biomolecules must therefore be tagged by a fluorescent marker to be visible in …

    tamu Repository record for High-Resolution Label Free Imaging of Endogenous Chromophore via Non-Linear Photoacoustic Microscopy (opens in a new tab)

  2. Photoacoustic Remote Sensing (PARS) Microscopy

    … proven to be power tools for visualizing optical absorption contrast within highly turbid media such as biological tissues. They provide high chromophore specificity in vivo due to the dramatic optical absorption contrast which exists between biological targets. This allows for non-ionizing …

    alberta Repository record for Photoacoustic Remote Sensing (PARS) Microscopy (opens in a new tab)

  3. Development of an all-optical non-contact label-free absorption microscopy system based on quadrature interferometry

    … has gained attention because it provides optical absorption contrast specific to various endogenous biomolecules in reflection-mode from optically thick samples. This contrast is otherwise attainable only in thin specimens using a trans-illumination setup. In this microscopy method, a focused …

    alberta Repository record for Development of an all-optical non-contact label-free absorption microscopy system based on quadrature interferometry (opens in a new tab)

  4. Development of a Multiphoton Photoacoustic Microscope

    … Many current techniques for subcellular absorption contrast imaging, such as two-photon excited fluorescence (TPEF), require exogenous contrast agents to gain access to many naturally occurring biomolecules. Non-fluorescent biomolecules must have a fluorescent marker (tag) chemically …

    tamu Repository record for Development of a Multiphoton Photoacoustic Microscope (opens in a new tab)

  5. All-Optical and Endoscopic Photoacoustic Microscopy

    … superficial structures in vivo with optical-absorption contrast. The term “optical resolution” is used since the lateral resolution of the system is defined by the optically-focused spot size, which is limited by the diffraction-limit of light. The axial resolution of the system is still …

    alberta Repository record for All-Optical and Endoscopic Photoacoustic Microscopy (opens in a new tab)

  6. Mesoscopic 3D Quantitative Imaging: Attenuation Correction with OPTiSPIM

    … (SPIM) in a hybrid setup (OPTiSPIM). In contrast to SPIM, that relys on fluorescent contrast, OPT can reconstruct data from absorbing contrast. Apart from having registered multimodal datasets by fusing data from different contrast mechanisms, the reconstructed absorption contrast …

    barcelona Repository record for Mesoscopic 3D Quantitative Imaging: Attenuation Correction with OPTiSPIM (opens in a new tab)

  7. Developments Towards Chromophore-Selectivity in Photoacoustic Remote Sensing Microscopy

    … Alexander Graham Bell, is sensitive to optical absorption contrast. This is highly useful in biomedical applications where the endogenous absorption contrast of tissue can directly be imaged, enabling label-free microscopy. Applications include histological assessment of tissue in support of …

    waterloo Repository record for Developments Towards Chromophore-Selectivity in Photoacoustic Remote Sensing Microscopy (opens in a new tab)

  8. Real-time blood oxygenation tomography with multispectral photoacoustics

    … medical ultrasonography with an optical absorption contrast. This enables tomographic imaging of blood oxygen saturation, a functional biomarker with wide applications. Already, photoacoustic imaging (PAI) is widely applied for small animal imaging in preclinical research. While PAI is a …

    heid-diss Repository record for Real-time blood oxygenation tomography with multispectral photoacoustics (opens in a new tab)

  9. Development And Application Of A Grating Interferometer At The Cornell High Energy Synchrotron Source

    Conventional x-ray absorption imaging is a powerful and commonly-used technique in a wide variety of fields, but it has limited applicability for softer, lighter materials and for specimens whose internal structure has only small differences in density. In these situations, phase-contrast imaging …

    cornell Repository record for Development And Application Of A Grating Interferometer At The Cornell High Energy Synchrotron Source (opens in a new tab)

  10. Design and simulation of chiral plasmonic metamaterial used for mid-infrared detection

    … time-domain (FDTD) simulations, the optical absorption characteristics and chiral response of the metamaterial are investigated across the MIR wavelength range of 3–8 μm. The results demonstrate that the optimized structure, with a dielectric thickness of 136 nm, achieves peak absorption …

    nanyang Repository record for Design and simulation of chiral plasmonic metamaterial used for mid-infrared detection (opens in a new tab)

  11. Fast widefield techniques for fluorescence and phase endomicroscopy

    … imaging techniques with fluorescence and phase contrast, respectively. Fluorescence imaging in thick tissue is often hampered by strong out-of-focus background signal. Laser scanning confocal endomicroscopy has been developed for optically-sectioned imaging free from background, but reliance on …

    bu Repository record for Fast widefield techniques for fluorescence and phase endomicroscopy (opens in a new tab)

  12. Development of a Matlab-Based Characterization Suite – Application to Metal Foam and Composite Ceramic Waste Form Microstructures

    … Nd2Ti2O7, were imaged using differential X-ray absorption contrast tomography (DXACT). DXACT is a synchrotron-based 3-D imaging technique capable of resolving spatial distributions of specific elements in a sample. Using the 3-D elemental maps obtained from DXACT, the microstructural properties …

    uconn-diss Repository record for Development of a Matlab-Based Characterization Suite – Application to Metal Foam and Composite Ceramic Waste Form Microstructures (opens in a new tab)

  13. Label-free photoacoustic microscopy for biomedical and point-of-care applications

    … Taking the advantage of endogenous optical absorption contrast, PAT can provide label-free structural, histological, functional, and metabolic images for clinical applications and basic studies. In this thesis, we propose several techniques to improve the performance of PAT and promote its …

    hkust Repository record for Label-free photoacoustic microscopy for biomedical and point-of-care applications (opens in a new tab)

  14. Micromachined Acoustic Delay Line Technologies For Photoacoustic Sensing Applications

    … which take the advantage of rich optical absorption contrast and deep acoustic penetration depth in tissues. However, current PAS devices are bulky, invasive, and susceptible to interference during excitation. In the thesis, miniaturized PAS probes based on acoustic delay lines (ADLs) are …

    tamu Repository record for Micromachined Acoustic Delay Line Technologies For Photoacoustic Sensing Applications (opens in a new tab)

  15. Photoacoustic imaging in regenerative medicine using endogenous and exogenous contrast agents

    … (PAI) or Optoacoustic imaging combines optical absorption contrast with ultrasonic resolution and utilises both endogenous and exogenous contrast agents for gathering molecular information in real-time. This enables longitudinal detection at clinically relevant penetration depths in vivo. The …

    galway Repository record for Photoacoustic imaging in regenerative medicine using endogenous and exogenous contrast agents (opens in a new tab)

  16. Magnetoelastic coupling in a quantum spin ladder

    … with the magnetization data. By plotting the absorption contrast (the integral of the absolute absorption difference) with the magnetization, we saw that the optical properties track the magnetization data with a small lag. The lag that we see is attributed to a slower lattice response in the …

    ut-knoxville Repository record for Magnetoelastic coupling in a quantum spin ladder (opens in a new tab)

  17. Delelopment of an x-ray prism for a combined diffraction enhanced imaging and fluorescence imaging system

    … of conventional radiography, which derives image contrast from absorption, by providing a large change in intensity for a small angle change introduced by the X-ray beam traversing the sample. Objects that have very little absorption contrast may have considerable refraction and ultra small angle …

    sask Repository record for Delelopment of an x-ray prism for a combined diffraction enhanced imaging and fluorescence imaging system (opens in a new tab)

  18. Photoacoustic imaging with clinical, preclinical, and quantitative applications

    … imaging modality that combines optical absorption contrast with ultrasonic resolution and imaging depth. Major research has been carried out into PAI in recent years, and as a result PAI is rapidly being established as a mainstream imaging modality in both biological research and …

    galway Repository record for Photoacoustic imaging with clinical, preclinical, and quantitative applications (opens in a new tab)

  19. Strain imaging using multimodal X-ray imaging

    … and polymers become ineffective due to reduced contrast-to-noise ratio, limiting precision and resolution. Phase contrast tomography, using synchrotrons or micro-focus X-ray systems, shows promise but is often inaccessible or limited by a small field of view. In this thesis X-ray strain imaging …

    ucl Repository record for Strain imaging using multimodal X-ray imaging (opens in a new tab)

  20. Towards non-invasive blood cell counting and analysis with oblique back-illumination capillaroscopy

    … for such a technology, a combined phase and absorption contrast microscopy technique called oblique back-illumination capillaroscopy. This technique enables non-invasive, label-free imaging of individual blood cells flowing through human capillaries with simple, relatively low-cost equipment. …

    jhu Repository record for Towards non-invasive blood cell counting and analysis with oblique back-illumination capillaroscopy (opens in a new tab)

Page 1 of 3