Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 17 of 17 for “"Accelerated corrosion test"”.
-
Accelerated Corrosion Test with Operation Simulation of All-Aluminum Microchannel Heat Exchangers
… exchangers. Furthermore, ASHRAE members and the corrosion community will find value in a defined corrosion system and corrosion test procedure. The information gained through past research has progressed assessment of material performance; however, the methods improperly simulate and expedite …
-
Inductively Coupled Corrosion Potential Sensor for Remote Passive Monitoring of New and Existing Civil Structures
… process of an inductively coupled coil corrosion potential sensor for long-term civil structure health monitoring remotely. This is of growing interest for decreasing the maintenance cost, reducing the deterioration significantly and increasing the safety. The thesis is organized …
-
Coupled Resonant Coil Sensors for Remote Passive Monitoring Applications
… coil sensor, which is able to monitor the corrosion potential of reinforcement steel is presented. Results of an accelerated corrosion test using the sensor indicate that corrosion potential can be monitored with a resolution less than 10 mV and a sensitivity of 0.76 kHz/mV. The last part …
-
Corrosion of Austenitic Stainless Steel
This thesis work focuses on the corrosion behaviour of austenitic stainless steel welds in chloride containing environments. The initial aim was to develop a new method for corrosion testing of welded austenitic stainless steel. The motivation for such work was that previous results indicated that …
-
Galvanic Corrosion of Aluminum Coupled to Passivating and Non-Passivating Alloys
Galvanic corrosion of 6061-T6 aluminum-coupled metals was studied in marine, volcanic, and rainforest environments. In addition to field research, galvanic couples were subjected to the chloride-containing GM-9540P accelerated corrosion test. The galvanic couple types included 6061-T6 Al with …
-
Corrosion Behavior of ASTM A1010 Stainless Steel for Applications in Bridge Components
… of this research was the investigation of the corrosion behavior of a low chromium-content stainless steel, ASTM A1010, for use in steel bridge members. This stainless steel has been marketed as a potential replacement for conventional structural steels for bridges located in highly-corrosive …
-
Bermudagrass (Cynodon dactylon) and Goosegrass (Eleusine indica) Management in Seashore Paspalum (Paspalum vaginatum) Turf.
… many applications. Its material properties and corrosion resistance has made it a popular alloy, especially for applications requiring lightweight materials. However, due to its active location in the galvanic series and EMF series, it can be very susceptible to galvanic corrosion. Hence, there …
-
Corrosion on Noble, Active, and Passivating Metals Galvanically Coupled to Aluminum
… many applications. Its material properties and corrosion resistance has made it a popular alloy, especially for applications requiring lightweight materials. However, due to its active location in the galvanic series and EMF series, it can be very susceptible to galvanic corrosion. Hence, there …
-
Alternative Methods for Sealing Overlapping Steel Members with Narrow Gaps During Galvanizing
… in six different overlapping configurations were tested. Three experimental tasks were performed as part of this research: two different types of silicone caulks were used to partially substitute the seal-weld to prevent fluid penetration; an accelerated corrosion test was performed to determine …
-
Long-period fiber grating corrosion sensors for life-cycle monitoring and assessment of reinforced concrete structures
… detection of the steel tube; (3) correlate the corrosion process of packaging metal materials with that of steel bars in direct contact with the packaged probe or sensor except for a thin insulation tape; and (4) apply both types of corrosion sensors into reinforced concrete (RC) structures for …
-
Fabrication and Characterization of Porous 316L Stainless Steel Using Selective Laser Melting Technique for Biomedical Applications
… all samples. The samples were subjected to an accelerated corrosion test for 336 hours using the salt spray chamber. 5 % wt. of NaCl formed part of the composition of the corrosive media, and by comparing the corrosion rates and weight loss of the interconnected structures, the samples …
-
Evaluation of the suitabil[i]ty of Fischer-Tropsch gas-to-liquid (GTL) Primary Column Bottoms as process cooling water : analysis of microbial community dynamics, fouling, scaling and corrosion
… by major problems (fouling, scaling and corrosion) due to the complicated chemistry of the process water and the increased nutrient loads within the system. The aim of this study was to evaluate the suitability of Fischer-Tropsch gas-to-liquid Primary Column Bottoms as process cooling …
-
Pipeline health monitoring using helical guided ultrasonic waves
… accidents are reported each year in the US with corrosion being one of the most common forms of failure causing significant wall-thickness and pressure loss. To this aim, this thesis investigates the use of active and passive acoustic methods to localize, monitor, and quantify corrosion in steel …
-
CORROSION INDUCED CRACKING IN CONCRETE
This project investigates the corrosion of steel embedded in mortar/concrete by impressed current. An attempt was made through this accelerated corrosion test to determine the inter-relationship between mortar quality, cover thickness and bar size on the intensity of corrosion to cause cracking. …
-
Evaluation Of Concrete Degradation Using Acoustic Emission: Data Filtering And Damage Detection
… the delivery of enhanced nondestructive testing (NDT) and structural health monitoring (SHM) methods. Acoustic emission (AE) is a strong candidate for these applications due to its high sensitivity and potential for damage detection in different materials. However, several challenges …
-
Magnetic Thin Films With High Perpendicular Anisotropy For Magnetic Recording Media Applications
… (25 °C) over 3 years, but they did not pass the accelerated corrosion test (130°C, 95%RH, 6 hours). A capping layer consisting of a hcp-phased CoPt-alloy layer and carbon overcoat should help Sm(Co, Cu)<sub>5</sub> thin films meet the requirements for future high-density magnetic recording …