  1. Effect of metallic restoration artifacts on maxillofacial cone beam computed tomography images.

    … acquisition parameters for three CBCT systems: Accuitomo 170 (J. Morita MFG. Corp, Kyoto, Japan), iCAT Next Generation (Imaging Sciences International Inc., Hatfield, PA, USA) and Carestream 9000 3D (Carestream/KODAK, Atlanta, GA). For all systems, HDOs significantly affected images throughout …

    louisville Repository record for Effect of metallic restoration artifacts on maxillofacial cone beam computed tomography images. (opens in a new tab)

  2. Die Abbildungsqualität des digitalen Volumentomographen 3DX im Vergleich zum konventionellen Panoramaschichtgerät

    … sowie das Auftreten von Artefakten auf Accuitomoaufnahmen und Panoramaschichtansichten. Die Ergebnisse dieser Studie zeigten insgesamt eine signifikant bessere Bewertung der allgemeinen Darstellungsqualität der mit dem 3D Accuitomo aufgenommenen Bilder (p=0,034) im Vergleich zu den …

    fu-berlin Repository record for Die Abbildungsqualität des digitalen Volumentomographen 3DX im Vergleich zum konventionellen Panoramaschichtgerät (opens in a new tab)

  3. Οπτική ανάλυση της ποιότητας της εικόνας στον οδοντιατρικό υπολογιστικό τομογράφο κωνικής δέσμης σύμφωνα με τις ευρωπαϊκές κατευθυντήριες οδηγίες

    … σύστημα) 2. NewTomVGI (2 συστήματα) 3.3D Accuitomo(1 σύστημα) ΑΠΟΤΕΛΕΣΜΑΤΑ Όσο αφορά στην ανάλυση της αντίθεσης των υλικών PTFE και LDPE παρατηρείται μια ελάχιστη διακύμανση, ενώ η αντιθετική διακριτική ικανότητα των Alu και Air σημειώνεται πάντα ως μέγιστη. Το υλικό DELRIN παρουσιάζει την …

    athens Repository record for Οπτική ανάλυση της ποιότητας της εικόνας στον οδοντιατρικό υπολογιστικό τομογράφο κωνικής δέσμης σύμφωνα με τις ευρωπαϊκές κατευθυντήριες οδηγίες (opens in a new tab)

  4. Reducing CBCT radiation dose and maintaining image quality for reliable cephalometric measurements – proof of concept

    … A human cadaver was scanned in the Morita Accuitomo 170® CBCT machine under the manufacturer recommended settings (5mA, 90kV, 360⁰) and multiple combinations of decreased exposure settings: 1, 2.5, 5 mA - 60, 70, 80, 90 kV - 180⁰ and 360⁰ rotation arc. Radiation dose was recorded for each …

    washington Repository record for Reducing CBCT radiation dose and maintaining image quality for reliable cephalometric measurements – proof of concept (opens in a new tab)

  5. Beam Hardening and Scatter Artifact with Metal Objects Inside and Outside the Field of View in CBCT Imaging

    … human cadaver’s left maxilla and imaged using Accuitomo 170 CBCT with limited FOV. Sixteen scans (7 with metal inside the FOV, 7 with metal outside the FOV, and two controls) were obtained. The artifacts were objectively evaluated by calculating the standard deviation (SD) of grayscale values …

    tamu Repository record for Beam Hardening and Scatter Artifact with Metal Objects Inside and Outside the Field of View in CBCT Imaging (opens in a new tab)

  6. Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study

    … and high-resolution CBCT (80 um voxel, J. Morita Accuitomo 170, 40 x 40 mm FOV). Micro-CT provided true canal diameters, which were anatomically matched to CBCT slices. Three calibrated observers (two endodontists, one oral radiologist) scored canal visibility on a 5-point rubric; scores greater …

    tamu Repository record for Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study (opens in a new tab) Embargoed until 2027-12-01

  7. Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study

    … and high-resolution CBCT (80 um voxel, J. Morita Accuitomo 170, 40 x 40 mm FOV). Micro-CT provided true canal diameters, which were anatomically matched to CBCT slices. Three calibrated observers (two endodontists, one oral radiologist) scored canal visibility on a 5-point rubric; scores greater …

    tamu Repository record for Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study (opens in a new tab) Embargoed until 2027-12-01

  8. Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study

    … and high-resolution CBCT (80 um voxel, J. Morita Accuitomo 170, 40 x 40 mm FOV). Micro-CT provided true canal diameters, which were anatomically matched to CBCT slices. Three calibrated observers (two endodontists, one oral radiologist) scored canal visibility on a 5-point rubric; scores greater …

    tamu Repository record for Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study (opens in a new tab) Embargoed until 2027-12-01

  9. Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study

    … and high-resolution CBCT (80 um voxel, J. Morita Accuitomo 170, 40 x 40 mm FOV). Micro-CT provided true canal diameters, which were anatomically matched to CBCT slices. Three calibrated observers (two endodontists, one oral radiologist) scored canal visibility on a 5-point rubric; scores greater …

    tamu Repository record for Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study (opens in a new tab) Embargoed until 2027-12-01

  10. Effect of the Leaded Glasses as an Exomass Object on CBCT Images

    … a human cadaver head were acquired with the 3D-Accuitomo 170 utilizing FOV of 100 × 50 mm, which placed the leaded-glasses outside the field of view (FOV). Scanning parameters considered three conditions of standard/high resolution, full/partial rotations, with/without leaded-glasses. Six …

    tamu Repository record for Effect of the Leaded Glasses as an Exomass Object on CBCT Images (opens in a new tab)

  11. The effect of tooth structure loss on the outcome of root canal retreatments: Experimental and clinical studies

    … using a built-in dose reduction (DR) mode in an Accuitomo CBCT machine at 360° and 180° rotations for detecting simulated apical radiolucencies in a human dry mandible model. Volumetric measurements of the intraoral digital scanner were validated against microcomputed tomography. The differences …

    kings Repository record for The effect of tooth structure loss on the outcome of root canal retreatments: Experimental and clinical studies (opens in a new tab) Download PDF for The effect of tooth structure loss on the outcome of root canal retreatments: Experimental and clinical studies (opens in a new tab)

  12. Ενεργός δόση στην υπολογιστική τομογραφία κωνικής δέσμης: Συστηματική Ανασκόπηση

    … οι περισσότερες μετρήσεις ήταν ο 3D Accuitomo 170 (34 μετρήσεις,16,1%), ο Kodak CS 9300 (20 μετρήσεις, Ενεργός δόση στην Υπολογιστική Τομογραφία Κωνικής Δέσμης: Συστηματική Ανασκόπηση 96 5%), ο Promax 3D (17 μετρήσεις, 8,09%) και ο VGI της Newtom (15 μετρήσεις, 7,1%). Για κάθε μοντέλο …

    athens Repository record for Ενεργός δόση στην υπολογιστική τομογραφία κωνικής δέσμης: Συστηματική Ανασκόπηση (opens in a new tab)