Effect of metallic restoration artifacts on maxillofacial cone beam computed tomography images.
… acquisition parameters for three CBCT systems: Accuitomo 170 (J. Morita MFG. Corp, Kyoto, Japan), iCAT Next Generation (Imaging Sciences International Inc., Hatfield, PA, USA) and Carestream 9000 3D (Carestream/KODAK, Atlanta, GA). For all systems, HDOs significantly affected images throughout …
-
Die Abbildungsqualität des digitalen Volumentomographen 3DX im Vergleich zum konventionellen Panoramaschichtgerät
… sowie das Auftreten von Artefakten auf Accuitomoaufnahmen und Panoramaschichtansichten. Die Ergebnisse dieser Studie zeigten insgesamt eine signifikant bessere Bewertung der allgemeinen Darstellungsqualität der mit dem 3D Accuitomo aufgenommenen Bilder (p=0,034) im Vergleich zu den …
-
Οπτική ανάλυση της ποιότητας της εικόνας στον οδοντιατρικό υπολογιστικό τομογράφο κωνικής δέσμης σύμφωνα με τις ευρωπαϊκές κατευθυντήριες οδηγίες
… σύστημα) 2. NewTomVGI (2 συστήματα) 3.3D Accuitomo(1 σύστημα) ΑΠΟΤΕΛΕΣΜΑΤΑ Όσο αφορά στην ανάλυση της αντίθεσης των υλικών PTFE και LDPE παρατηρείται μια ελάχιστη διακύμανση, ενώ η αντιθετική διακριτική ικανότητα των Alu και Air σημειώνεται πάντα ως μέγιστη. Το υλικό DELRIN παρουσιάζει την …
-
Reducing CBCT radiation dose and maintaining image quality for reliable cephalometric measurements – proof of concept
… A human cadaver was scanned in the Morita Accuitomo 170® CBCT machine under the manufacturer recommended settings (5mA, 90kV, 360⁰) and multiple combinations of decreased exposure settings: 1, 2.5, 5 mA - 60, 70, 80, 90 kV - 180⁰ and 360⁰ rotation arc. Radiation dose was recorded for each …
-
Beam Hardening and Scatter Artifact with Metal Objects Inside and Outside the Field of View in CBCT Imaging
… human cadaver’s left maxilla and imaged using Accuitomo 170 CBCT with limited FOV. Sixteen scans (7 with metal inside the FOV, 7 with metal outside the FOV, and two controls) were obtained. The artifacts were objectively evaluated by calculating the standard deviation (SD) of grayscale values …
-
Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study
… and high-resolution CBCT (80 um voxel, J. Morita Accuitomo 170, 40 x 40 mm FOV). Micro-CT provided true canal diameters, which were anatomically matched to CBCT slices. Three calibrated observers (two endodontists, one oral radiologist) scored canal visibility on a 5-point rubric; scores greater …
-
Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study
… and high-resolution CBCT (80 um voxel, J. Morita Accuitomo 170, 40 x 40 mm FOV). Micro-CT provided true canal diameters, which were anatomically matched to CBCT slices. Three calibrated observers (two endodontists, one oral radiologist) scored canal visibility on a 5-point rubric; scores greater …
-
Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study
… and high-resolution CBCT (80 um voxel, J. Morita Accuitomo 170, 40 x 40 mm FOV). Micro-CT provided true canal diameters, which were anatomically matched to CBCT slices. Three calibrated observers (two endodontists, one oral radiologist) scored canal visibility on a 5-point rubric; scores greater …
-
Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study
… and high-resolution CBCT (80 um voxel, J. Morita Accuitomo 170, 40 x 40 mm FOV). Micro-CT provided true canal diameters, which were anatomically matched to CBCT slices. Three calibrated observers (two endodontists, one oral radiologist) scored canal visibility on a 5-point rubric; scores greater …
-
Effect of the Leaded Glasses as an Exomass Object on CBCT Images
… a human cadaver head were acquired with the 3D-Accuitomo 170 utilizing FOV of 100 × 50 mm, which placed the leaded-glasses outside the field of view (FOV). Scanning parameters considered three conditions of standard/high resolution, full/partial rotations, with/without leaded-glasses. Six …
-
The effect of tooth structure loss on the outcome of root canal retreatments: Experimental and clinical studies
… using a built-in dose reduction (DR) mode in an Accuitomo CBCT machine at 360° and 180° rotations for detecting simulated apical radiolucencies in a human dry mandible model. Volumetric measurements of the intraoral digital scanner were validated against microcomputed tomography. The differences …
-
Ενεργός δόση στην υπολογιστική τομογραφία κωνικής δέσμης: Συστηματική Ανασκόπηση
… οι περισσότερες μετρήσεις ήταν ο 3D Accuitomo 170 (34 μετρήσεις,16,1%), ο Kodak CS 9300 (20 μετρήσεις, Ενεργός δόση στην Υπολογιστική Τομογραφία Κωνικής Δέσμης: Συστηματική Ανασκόπηση 96 5%), ο Promax 3D (17 μετρήσεις, 8,09%) και ο VGI της Newtom (15 μετρήσεις, 7,1%). Για κάθε μοντέλο …