Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 36 for “"Accuracy Measurement"”.

  1. Historical phasor measurement unit (PMU) data analysis by using machine learning techniques for anomaly detection in power systems

    The ability of the phasor measurement units to capture the fast dynamics of the power system with high accuracy measurement has become a more popular technology in utility industry due to its efficiency when comparing with traditional SCADA systems. Power system data analysis is more important in …

    ttu Repository record for Historical phasor measurement unit (PMU) data analysis by using machine learning techniques for anomaly detection in power systems (opens in a new tab)

  2. Mobofoto: a mobile platform for concentration measurement through colorimetric analysis

    Traditional colorimetric measurement is widely used in chemical concentration estimation. However, compared to the laboratory solutions for accurate measurements with professional measuring equipment, colorimetric measurement is often more qualitative than quantitative. It would be most productive …

    uiuc Repository record for Mobofoto: a mobile platform for concentration measurement through colorimetric analysis (opens in a new tab)

  3. Demand forecasting: an evaluation of DOD's accuracy metric and Navy's procedures

    … the Department of Defense (DOD) implemented an accuracy metric to monitor how well the services and Defense Logistics Agency were forecasting demand for inventory items. After three years, results were still poor. DOD uses a metric derived from the Mean of Absolute Percentage Error, yet it …

    nps Repository record for Demand forecasting: an evaluation of DOD's accuracy metric and Navy's procedures (opens in a new tab)

  4. Digitisation of Conventional Water Meters Using Automated Number Recognition

    … water meter has the characteristics of accuracy measurement precision, simple structure, zero power dissipation and high reliability, it still needs a worker to record the meter readings door-by-door. With the development of image processing technology, people spend a large amount of …

    auckland-tech Repository record for Digitisation of Conventional Water Meters Using Automated Number Recognition (opens in a new tab)

  5. Flight Path Planning and Optimization for High-Resolution Imaging in Open Pit Mines by UAVs

    … detection and characterization, drill holes accuracy measurement, blast fragmentation or evaluating the condition of ramps. All these applications require high resolution and accurate 3-D models of the mine. For example, despite advances in slope monitoring, identification of tension crack …

    unr Repository record for Flight Path Planning and Optimization for High-Resolution Imaging in Open Pit Mines by UAVs (opens in a new tab)

  6. Very low noise cryogenic receivers and measurement electronics

    … low noise cryogenic receivers and related high accuracy measurement setups to validate the operation of the receivers. Different types of cryogenic noise measurement setups were developed and compared. The noise measurement accuracy was improved for cryogenic temperatures at millimeter wave …

    aalto Repository record for Very low noise cryogenic receivers and measurement electronics (opens in a new tab)

  7. Accurate Linearizations for Relaxed FIFO queues

    … which are out-of-order. Rank error is an accuracy measurement for operations on relaxed queues and is often used when evaluating a newly developed relaxed queue. The current method of measuring rank error for operations on a queue is based on an approximation of when operations take …

    chalmers Repository record for Accurate Linearizations for Relaxed FIFO queues (opens in a new tab)

  8. Development of digital instrumentation for bond rupture detection : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Engineering at Massey University, Palmerston North, New Zealand

    … Rupture effect has been observed via the high accuracy measurement of the frequency change while inducing Bond Rupture on the sensor, proving that the Bond Rupture effect indeed exists. The research performed is believed to be a world first in terms of the method used and accuracy acquired.

    massey Repository record for Development of digital instrumentation for bond rupture detection : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Engineering at Massey University, Palmerston North, New Zealand (opens in a new tab)

  9. Laser cooling of iron atoms

    … spectroscopy. With the same technique, a high accuracy measurement of the iron 358-nm transition frequency with respect to the molecular-iodine R(90)3-10 transition was performed. For this measurement, we implemented a particular configuration which allowed for the minimising of an important …

    liege Repository record for Laser cooling of iron atoms (opens in a new tab)

  10. A higher-order accurate unstructured finite volume Newton-Krylov algorithm for inviscid compressible flows

    … is introduced. The issue of mesh refinement in accuracy measurement for unstructured meshes is revisited. A straightforward methodology is applied for accuracy assessment of the higher-order unstructured approach based on total pressure loss, drag measurement, and direct solution error …

    ubc Repository record for A higher-order accurate unstructured finite volume Newton-Krylov algorithm for inviscid compressible flows (opens in a new tab) Download PDF for A higher-order accurate unstructured finite volume Newton-Krylov algorithm for inviscid compressible flows (opens in a new tab)

  11. Analysis and New Developments Towards Reliable and Portable Measurements in Deflectometry

    … uses off-the-shelf equipment to achieve nm-level accuracy measurement. This process is typically made by scanning lines of pixels or encoding the surface slopes information with phase using sinusoidal waves. Various measurement techniques exist, centroiding and phase-shifting being the most …

    arizona-thes Repository record for Analysis and New Developments Towards Reliable and Portable Measurements in Deflectometry (opens in a new tab)

  12. Characterizing the Dielectric Properties of Geologic and Asteroid Regolith Analogue Material for Improved Planetary Radar Interpretation

    … to describe the experimental permittivity measurements. A thorough analysis of the experiments was performed which showed that the Looyenga-Landau-Lifshitz and Bruggeman (Symmetric) mixing models described the experimental results with the highest accuracy. Measurement bias in the coaxial …

    york Repository record for Characterizing the Dielectric Properties of Geologic and Asteroid Regolith Analogue Material for Improved Planetary Radar Interpretation (opens in a new tab)

  13. Designing, Implementing, and Evaluating an Online Instructional Program to Teach Students to Evaluate Systemic Social Issues Using a Matrix Analysis

    … needed to conduct a matrix analysis, the accuracy with which participants embedded these elements in a matrix analysis diagram, and the qualitative value of those elements. The development of the online training program was completed through a series of recursive steps. First, four …

    unt Repository record for Designing, Implementing, and Evaluating an Online Instructional Program to Teach Students to Evaluate Systemic Social Issues Using a Matrix Analysis (opens in a new tab)

  14. Doppler Radar Techniques for Distinct Respiratory Pattern Recognition and Subject Identification

    … Doppler radar has been used for displacement measurement and vital signs detection in many state-of-the-art studies. However, further improvement, i.e., accurate radar characterization of respiration, may allow sleep diagnostics and unique subject identification. A low distortion DC coupled …

    hawaii Repository record for Doppler Radar Techniques for Distinct Respiratory Pattern Recognition and Subject Identification (opens in a new tab)

  15. Application of optical techniques to surveying

    … that has not fully matured for medium range measurement with few systems having been developed and little research material produced. However, the research carried out for this thesis shows that providing all the factors that contribute errors of measurement are understood, then a fast, …

    city-london Download PDF for Application of optical techniques to surveying (opens in a new tab)

  16. Flow Boiling Heat Transfer in a Long, Small Diameter, Vertically Oriented, Uniformly Heated Tube

    … critical heat flux data. The experimental measurement accuracy, measurement speed, maximum inlet temperature, and flow control will be improved. This will be achieved by improving the thermocouple shielding and isolation, modifying and adding new data acquisition instrumentation, adding a …

    mcmaster Repository record for Flow Boiling Heat Transfer in a Long, Small Diameter, Vertically Oriented, Uniformly Heated Tube (opens in a new tab)

  17. Preformulation and Formulation Development of a Novel Radioprotectant Drug

    … include specificity, linearity, precision, accuracy and sensitivity. The retention time of the drug and the other effluents were well within seven minutes. Standard curves were linear over the concentration range of 10-500 [Ag/ml. The RSD values for the within-day and day-to-day precision …

    creighton Repository record for Preformulation and Formulation Development of a Novel Radioprotectant Drug (opens in a new tab) Embargoed until 2100-01-01

  18. Optical Frequency Domain Reflectometry: Sensing Range Extension and Enhanced Temperature Sensitivity

    … high spatial resolution and high sensing accuracy. However, current limitation on OFDR lies in the sensing range and sensing accuracy. The state of art performance of commercial OFDR provides ~70m sensing range as well as 0.1K temperature accuracy. This is not adequate for large building …

    ottawa-retro Repository record for Optical Frequency Domain Reflectometry: Sensing Range Extension and Enhanced Temperature Sensitivity (opens in a new tab)

  19. Přímý postih přetížených vozidel na základě měření vysokorychlostními systémy HS WIM

    Tato diplomová práce se zabývá systémy a technologií vysokorychlostního vážení. Jejím hlavním cílem je hodnocení přesnosti stanic vysokorychlostního vážení při různých konfiguracích senzorů ve stanicích. Součástí práce je také rozbor jednotlivých senzorů, které se používají pro stanice s …

    brno-tech Repository record for Přímý postih přetížených vozidel na základě měření vysokorychlostními systémy HS WIM (opens in a new tab)

  20. Neutron capture cross section measurements by the activation method at the n_TOF NEAR station

    … the end of long flight paths in order to perform measurements using the time-of-flight (TOF) technique, and one right next to the spallation target itself, benefiting from high neutron flux. This third experimental area, the "NEAR" station, could potentially be used to perform integral MACS …

    greece Repository record for Neutron capture cross section measurements by the activation method at the n_TOF NEAR station (opens in a new tab)

Page 1 of 2