Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 130 for “"Active Pixel"”
-
Active pixel sensors for X-ray astronomy
An active pixel sensor array, APS-1, has been fabricated for the purpose of scientific x-ray detection. This thesis presents the results of testing the device. Alternate design architectures are explored. Recommendations are made for a next-generation sensor. CCDs have been the dominant x-ray …
-
Characterization of depleted monolithic active pixel sensors
<p>Monolithic active pixel sensors are a viable detector option for many high energy particle physics experiments, as they reduce both the production cost and the amount of material required in a detector. They are produced in CMOS (Complementary Metal-Oxide Semiconductor) processes, which are …
-
High fill factor CMOS active pixel image sensor design
… benefited from technology scaling, the CIS pixel pitch has been continuously reduced to increase pixel density and spatial resolution. However, reduction in pixel pitch would also reduce the in-pixel photosensing area and lead to degradation in CIS performance such as sensitivity, …
-
Development of monolithic active pixel sensors for radiation imaging
The development of Fully Depleted Monolithic Active Pixel Sensors (FD-MAPS) represents nowadays a hot-topic in the radiation detector community. The advantages in terms of production costs and easiness of manufacturing in comparison to the state-of-the-art hybrid detectors boost the research effort …
-
Low voltage CMOS active pixel image sensor design and implementation
<p>CMOS Active Pixel Sensor (APS) takes the advantage of the mature CMOS industry to compete with the Charge-Coupled Devices (CCD). The advantage of CMOS APS includes low supply voltage, high integration, and flexible functions. However, the scaling of conventional CMOS Active Pixel Sensors (APS) …
-
Tests and simulations of the MIMOSIS CMOS monolithic active pixel sensor
MIMOSIS est un capteur monolithique actif à pixels CMOS développé pour le Micro Vertex Detector de l’expérience Compressed Baryonic Matter (CBM) au FAIR. Il doit offrir une résolution spatiale de 5 µm, une résolution temporelle de5 µs, supporter des taux de chocs jusqu’à 80 MHz/cm² et résister à …
-
A New electronic image array: The Active pixel charge injection device
… of the work described in this dissertation, the active pixel charge injection device (AP-CID) has been developed. This device retains most of the positive features of both the charge injection device (CJD) imager (random readout, non destructive readout, antiblooming, increased UV sensitivity, …
-
TCAD Simulations and Characterization of High-Voltage Monolithic Active Pixel Sensors
High- Voltage Monolithic Active Pixel Sensors (HV-MAPS) have emerged as a promising technology for silicon tracking detectors in particle physics. HV-MAPS, selected as the foundational technology for the Mu3e Pixel Tracker and under investigation for potential implementation in future detector …
-
Study of CMOS active pixel image sensor on SOI/SOS substrate
<p>A new pixel architecture, PMOS-reset Active Pixel Sensor, was built on SOI substrate in order to overcome the limit of output voltage swing because of V<sub>DD</sub> scaling. The photodiode was built on a substrate and the reset transistor and in-pixel amplifying transistor were built on the top …
-
Active pixel sensors for breast biopsy analysis using x-ray diffraction.
… complementary metal oxide semiconductor (CMOS) Active Pixel Sensors will soon be able to meet all of these demands in a single device. Characterization of two novel Active Pixel Sensors that advance towards an ideal X-ray diffraction detector is presented. 'Vanilla' exhibits a low read noise of …
-
Active Pixel Sensor Architectures for High Resolution Large Area Digital Imaging
… from traditional switching applications to on-pixel signal amplification for large area digital imaging and in particular, is aimed towards enabling emerging low noise, high resolution and high frame rate medical diagnostic imaging modalities such as digital tomosynthesis. A two transistor (2T) …
-
Development of low power front-end electronics for monolithic Active Pixel Sensors
… commonly used for high rate environments are pixel sensors. This research activity focuses mainly on two particular types of these sensors: hybrid pixel sensors and monolithic active pixel sensors (MAPS). Modern detectors use intensively hybrid sensors due to their excellent properties. This …
-
Development of Depleted Monolithic Active Pixel Sensors for High Energy Physics Experiments
Monolithic pixel detectors have attracted increasing interest in the HEP community, because of their advantages over the traditional hybrid detectors in terms of manufacture cost, fabrication simplicity and detector thickness. The DMAPS (Depleted Monolithic Active Pixel Sensors) variant has the …
-
Current Programmed Active Pixel Sensors for Large Area Diagnostic X-ray Imaging
… of high-performance, low-power, low-cost active matrix flat panel imagers. Despite the shortcomings associated with the instability and low mobility of TFTs, the amorphous silicon TFT technology still remains the primary solution for the backplane of flat panel imagers. The use of a-Si:H …
-
CMOS Active Pixel Sensors for Digital Cameras: Current State-of-the-Art
… metal oxide semiconductor (CMOS) based active pixel sensors (APS), which are characterized by reduced pixel size, give fast readouts and reduced noise. APS are used in many applications such as mobile cameras, digital cameras, Webcams, and many consumer, commercial and scientific …
-
A novel depleted monolithic active pixel sensor for future high energy physics detectors
… monolítico conocido como Depleted Monolithic Active Pixel Sensor on silicon-on-insulator ha sido investigado en esta tesis. El capítulo 1 describe el LHC, el experimento ATLAS, y las mejoras previstas para el HL-LHC. Este capítulo también describe los requerimientos y desafíos del futuro Inner …
-
Real-time, upstream, radiotherapy verification using a CMOS Monolithic Active Pixel Sensor System
… system using an array of CMOS Monolithic Active Pixel Sensors (MAPS). The system is designed for two key functions: real-time, high-precision reconstruction of Multi-Leaf Collimator (MLC) positions to verify beam shape, and accurate dosimetry. This approach provides the direct, sub-second …
-
Beam monitoring system for therapeutic ion beams based on HV-CMOS active pixel sensors
… sensor family, a series of HV-CMOS Monolithic Active Pixel Sensors with counting electronics and frame-based readout tailored for ion beam monitoring. The sensors characterization is performed in laboratory and ion beam environments and is followed by the development and production of first …
Page 1 of 7