Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 60 for “"Actuation Frequency"”
-
Design, Fabrication, and Testing of a 3D Printer Based Microfluidic System
… respect to the pumps driving pressure and the actuation frequency. Tested at a driving pressure of 10psi, the flowrate for device 1 peaked at 75µL/min with a 7Hz actuation frequency before failing, while device 2 peaked at 498µL/min with a 15Hz actuation frequency. Using the techniques of rapid …
-
Development of a fuel-powered compact SMA (Shape Memory Alloy) actuator system
… to estimate maximum available force, strain and actuation frequency. Multi-channel combustor/heat exchanger and micro-tube heat exchanger were designed and tested to achieve high heat transfer rate and high compactness. The final SMA actuator system was composed of pumps, valves, bellows, …
-
InsulPatch: A Slim, Powerless Microfluidic Patch-Pump for Insulin Delivery
… widths over a range of physiologically relevant actuation frequencies and pressures. We have found that for the specific channel design we have been using, the flow rate generally positively correlates with the actuation pressure. For devices with wider flow channels, the flow rate generally …
-
The Integration of Gallium-Based Liquid Metal Energy Circuits into Additively Manufactured Shape Memory Alloy Actuators for Increased Actuation Frequencies
… limited to applications with low cyclic actuation frequency due to their high thermal masses coupled with low heat transfer rates. Liquid gallium-indium eutectic is a room-temperature liquid metal that can be used as a multifunctional heat transfer fluid. Integrated into an additively …
-
Experimental Investigation of the Flow Generated by a Flexible, Flapping Membrane based on a Soft Electromagnetic Actuator
… from the wake in experiments defined by actuation current, actuation frequency and channel width. A custom fabrication process yields a SEMA membrane with an electrical resistance of R=0.248 Ω and a <10% deviation across all test combinations. The wake’s behaviour yields three types of …
-
Laminar Separation Control of an Eppler 387 Airfoil
… analysis was used to determine an optimal actuation frequency and locationto reduce the laminar boundary layer separation bubble on an Eppler 387 airfoil. Thegain curve provides a narrow range of frequencies which should provide signifcant”no-cost” amplifcation exploited by the actuators. A …
-
Turbine Passage Vortex Response to Upstream Periodic Disturbances
… flow behavior in both locations. The size and frequency of the disturbances had a nonlinear impact on the vortex size and strength. Fourier analysis revealed that the actuation frequency caused a harmonic response, and a change in the temporal behavior of the passage vortex. Each actuation …
-
Experimental Investigation Into Utilizing Synthetic Jet Actuators to Suppress Bi-modal Wake Behavior Behind an Ahmed Body
… total coefficient of momentum of 1.0E-3 with a frequency range up to 2000 Hz or F+ = 17.25. The piezoelectric actuators used were bimorph bending disks with no center shim and were driven by a square waveform. Pressure data was collected from 25 pressure ports on the rear of the model at 625 Hz …
-
Wake Response to Constant Frequency Actuation of Rectangular Prisms using Synthetic Jet Actuators
… prisms to synthetic jets driven at a constant frequency. The purpose of this investigation is two-fold. First, to determine the difference in the wake response of rectangular prisms with thickness-to-chord ratios in different dynamic regions. Second, to determine how perturbations of the shear …
-
Numerical Study of Synthetic-Jet Actuation Effect on Airfoil Trailing Edge Noise
… a low-pass filtering of poorly resolved high-frequency solution content to retain numerical accuracy and stability over the range of transitional flow regimes. In the adopted numerical procedure, the actuator is modeled without its resonator cavity through imposing a simple …
-
Active flow control of a precessing jet
… on the periphery of the nozzle inlet are used as actuation and near-field pressure data is measured by four pressure probes at the chamber exit to monitor the flow behavior. A phase plane, based on pressure signals, is used to find a Reynolds number and actuation frequency range where actuation …
-
CONTROL OF FLOW AROUND AN AEROFOIL AT LOW REYNOLDS NUMBERS USING PERIODIC SURFACE MORPHING
… to be a function of both the amplitude and frequency of the input voltage signal but the addition of aerodynamic forces does not cause significant changes in surface behaviour. The flow around the actuated aerofoil was compared with the unactuated flow. The latter exhibits large separation …
-
AC Electrothermal Fluid Transport for Biofluid Applications
… Parameters including number of electrode arrays, actuation patterns, and the thermal characteristics of the channel wall material were found to greatly influence the micropump performance. Other parameters, such as ambient temperature, actuation frequency, and channel wall thickness had the least …
-
DESIGN AND OPTIMIZATION OF PERISTALTIC MICROPUMPS USING EVOLUTIONARY ALGORITHMS
… used for optimizing the pump geometry and the actuation frequency. A simple example with moving walls is considered for validation by developing an exact analytical solution of Navier–Stokes equation and comparing it with numerical simulations. Possible applications of these pumps are in …
-
DEVELOPMENT OF AN AERODYNAMIC SYNTHETIC JET ACTUATOR BASED ON A PIEZOCERAMIC BUCKLED BEAM
… and jet velocity was only mildly dependent of actuation frequency.
-
Characterization of High Momentum Flux Combustion Powered Fluidic Actuators for High Speed Flow Control
… modes for the device. Momentary (pulsed) actuation jets are produced by the ignition of a mixture of gaseous fuel and oxidizer within a small (cubic centimeter scale) combustion chamber. The combustion process yields a high pressure burst (1 to 3 ms in duration in the typical …
-
Experimental characterization of the response of single and coaxial counter-rotating rotors to dynamic collective pitch inputs
… with an amplitude of Δθ₀ = 1° over a range of actuation frequencies of f = 0.0/rev, 0.2/rev, 0.3/rev, 0.4/rev, 0.6/rev, and 0.7/rev. The stepped-sine inputs are implemented on the isolated single rotor and CCR rotor configurations. There are four main test conditions for the CCR rotor …
-
Design of an Integrated Electrostatic Atomic Force Microscope
… the tip deflection, or the amplitude and frequency of its vibration. In each case (mode), the interaction forces between the sharp tip and the specimen govern the measured parameter which is detected optically by a laser beam reflected of the probe back side. A piezoelectric actuator …
-
Designing oscillating cilia for regulating particle motion in microfluidic devices
… the ciliated layer. We study the effect of actuation frequency on the particle motion inside the ciliated layer. We show that depending on the frequency, particles can be either driven away from the ciliated channel wall or drawn towards the wall. We also examine how to use inclined cilia to …
-
Numerical Study of Nozzle Geometry Effects on Three-Dimensional Offset Synthetic Jets
… diameter (d) of Re_0 = 580, and at a fixed actuation frequency of 300 Hz. Four nozzle geometries with identical cross-sectional area and an offset height of 2d from the wall were examined: circular, square, and rectangular nozzles with aspect ratios of AR = 3 and AR = 1/3. Instantaneous, …
Page 1 of 3