Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 11 of 11 for “"Acuros XB"”.
-
Investigation of Acuros XB radiotherapy dose calculation algorithm
… Recently, Varian has introduced a new algorithm, Acuros XB, which solves the Linear Boltzmann Transport Equation (LBTE). This study assesses the accuracy of dose calculations performed with Acuros. In this study, a Monte Carlo model was created using the EGSnrc family of Monte Carlo code, in order …
-
Σύγκριση των αλγόριθμων Acuros XB και ΑΑΑ και δοσιμετρική επιβεβαίωση πλάνων θεραπείας με τεχνική VMAT στην Ακτινοθεραπεία
… ήταν η αξιολόγηση της ακρίβειας του αλγόριθμου Acuros XB (AXB) και η σύγκριση του με τον Ανισοτροπικό Αναλυτικό Αλγόριθμο (Anisotropic Analytical Algorithm, AAA) σε πλάνα ογκομετρικά διαμορφούμενης τοξοειδούς ακτινοθεραπείας (Volumetric Modulated Arc Therapy, VMAT), όσον αφορά το δοσιμετρικό …
-
Evaluation of a deterministic Boltzmann solver for radiation therapy dose calculations involving high-density hip prostheses
Acuros External Beam (Acuros XB) is a new radiation dose calculation algorithm available as part of Varian Medical Systems' radiotherapy treatment planning system, ECLIPSE. Acuros XB calculates dose distributions by finding the deterministic solution to the linear Boltzmann transport equation which …
-
Δημιουργία, εκπαίδευση και εφαρμογή knowledge based planning (KBP) μοντέλων σε VMAT πλάνα ακτινοθεραπείας
… ως προς τον αλγόριθμο υπολογισμού δόσης (AAA και Acuros-XB) με 114 και 67 περιπτώσεις αντίστοιχα. Η ποιότητα των μοντέλων αξιολογήθηκε μέσω σύγκρισης με τα αντίστοιχα κλινικά πλάνα, χρησιμοποιώντας δοσιμετρικούς δείκτες για PTV και OARs, καθώς και μέσω ανάλυσης γ-index (3%/2mm) στο πλαίσιο ελέγχων …
-
Dosimetry at extreme non-charged particle equilibrium conditions using Monte Carlo and specialized dosimeters
… beams. MC calculations were used, along with Acuros XB, anisotropic analytical algorithm (AAA), GafChromic EBT2 film, and MOSkin dosimeters. PDDs were calculated and measured in these heterogeneous phantoms. The result of this study showed that Acuros XB, AAA, and MC calculations were within …
-
Physics and Geometry Input-Based Neural Network Dose Engine with Control Point Input Generator
… by comparing the predicted dose with Eclipse Acuros XB calculations. Results: MC-MUV simulation with 5 × 107 histories per arc offered good agreement with Eclipse and a reasonable average calculation time of 9–18 min per full plan. The average absolute dose difference was 3.0%; in contrast to …
-
Flattening Filter Free photon beams for treatment of early-stage lung cancer: an investigation of peripheral dose
… MLC fields, (2) Validation of Monte Carlo, Acuros XB and AAA algorithms for peripheral dose prediction, and (3) Evaluation of peripheral doses for VMAT lung SABR treatments using the validated Monte Carlo model. Measurements of out-of field doses for static open, static MLC and dynamic MLC …
-
Analyzing the Dosimetric Impact of CT Artifacts from High-Density Objects in Radiotherapy Planning
… were compared to dose calculations made by Acuros XB (AXB). This study aims to inform policies and practices on how to manage artifacts caused by these high-density objects and to identify the areas where increased or decreased effort may be necessary.
-
On Tumor Motion, Delineation Strategies, and Respiratory Induced Density Variations Associated with Stereotactic Lung Radiotherapy
… decrease in calculated lung dose when using Acuros XB over the Analytic Anisotropic Algorithm (AAA).
-
Development and Evaluation of Novel Applications for the Ethos CBCT-Guided Online Adaptive Radiotherapy System
… (Fourier transform dose calculation (FTDC) and Acuros XB) used in the Ethos system. In the third chapter, we have developed an initial planning strategy for H&N patients treated with sequential boost (SEQ) and simultaneous integrated boost (SIB) in the new Ethos treatment planning system (TPS). …