Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 34 for “"Adiabatic calorimeter"”
-
Automatic shield control for a moderate temperature adiabatic calorimeter.
… electronic controller was designed for use with adiabatic calorimeters. The controller employed reset action, and its behavior at different system gains was analyzed using the analytic techniques of feedback control theory. In accord with the analysis satisfactory performance was obtained with a …
-
The direct digital control of a dynamic adiabatic calorimeter
… sets forth a procedure used to place a dynamic adiabatic calorimeter under direct digital control. This process is inherently non-linear and multivariable as typical of many industrial processes. ,The process was placed under control by developing a detailed model of the process on both a …
-
A Study of the Operating Characteristics of an Adiabatic Calorimeter
… is concerned with the development of a calorimeter which has the capabilities for obtaining specific and latent heat data on these materials in the temperature range of ambient to 1,000° C. The criteria for this development are a. that operation be easy: the calorimeter should be …
-
A new adiabatic calorimeter and some thermal properties of deuterium oxide
… index, and bibliography. A brief discussion of adiabatic calorimetry is given in the introduction. Section I deals with the determination of some thermal properties of deuterium oxide and is divided into two parts. Part I deals with the specific heats of the solid and the latent heat of fusion. …
-
The construction of an adiabatic calorimeter and its use in measuring specific heats
A fluidless adiabatic calorimeter was constructed and was used to measure the specific heats of manganese-aluminum-carbon and manganese-zinc-carbon alloys from -150° to 150°C. In an adiabatic calorimeter, the temperature of a shield surrounding the calorimeter vessel is kept at approximately the …
-
A New Adiabatic Calorimeter for Specific Heat Determinations from 100° to 800°C
<p>Calorimeters of various types exist by which certain thermal energy of substances can be measured. A program of dynamic adiabatic calorimetry was initiated at The University of Tennessee in 1950 to further existing work on specific heat data. The calorimeters have continuously been improved in …
-
The data acquisition from and the theoretical modeling of a dynamic adiabatic calorimeter
… 1), capable of collecting data from the calorimeter with sufficient accuracy for modeling, control and specific heat measurements, were successfully accomplished. This system contains a fixed suppression-variable suppression-high gain amplification scheme which allows the sensing elements …
-
The construction and operating method of a new adiabatic calorimeter for measuring specific heats and heats of vaporization of liquids
… accuracy; The ordinary Williams and Danielle adiabatic calorimeter was found to be impractical* Several years ago a calorimeter for measuring the specific heat of liquid hydrocarbons near room temperatures was developed at the U.S. Bureau of Standards, A study of this instrument proved that it …
-
A calorimetric investigation of the heat effects in plasticly deformed A. I. S. I. 304L stainless steels
… investigation was to determine if the dynamic adiabatic calorimeter could be used to measure heat effects in plasticly deformed austenitic stainless steels. The data presented show that heat effects can be measured. In fact several such effects were observed but not enough information was …
-
Part 1: Operational characteristics of a low temperature adiabatic calorimeter at the University of Tennessee. Part 2: Contributions to the heat capacity of solid Molybdenum (20-2890 K.)
… characteristics of the low temperature adiabatic calorimeter in this Department. The principles of operation are discussed and a detailed description is given of the calorimeter. Operational procedures are outlined and problems faced during operation and their remedies are discussed in …
-
Thermal Stability Studies of Benzoyl Peroxide Systems
… experimentally using screening techniques and adiabatic calorimeter. Significant differences in thermal behavior and reaction pathways were observed in different systems involving BPO. Solid BPO was tested in pseudo-adiabatic calorimeter to study the condition-dependent BPO decomposition, …
-
The heat capacity of gelatin gels.
… between -180° and 25°C.,have been measured. The adiabatic calorimeter used permits a much higher degree of accuracy than has been previously attained in such measurements. Such previous measurements as have been made on gelatin gels cover a mnch more restricted range of temperature and …
-
DISORDER IN MATERIALS
… of polymeric electrolyte materials using adiabatic calorimetry and other techniques, in order to obtain more information about their structure and conduction. In addition, extended x-ray absorption fine structure (BXAFS) was to be used toprobe the local structural changes that occur in …
-
Polymorphism in Solid 1,1,1-trichloroethane and Solid 2,2-dichloropropane
… of 1,1,1-trichloroethane with a high precision adiabatic calorimeter. It has confirmed the general description of the interrelation between the different phases given here as well as the strategic role played by impurities.</p>
-
A comparison of the personal development of American and Chinese college students within an Ericksonian framework
… sets forth a procedure used to place a dynamic adiabatic calorimeter under direct digital control. This process is inherently non-linear and multivariable as typical of many industrial processes. ,The process was placed under control by developing a detailed model of the process on both a …
-
Numerical and experimental study of transient heat transfer through concrete.
… of the heat of hydration curve using the adiabatic calorimeter and experimental determination of transient heat transfer obtained from measurement of temperature variations in concrete at its early ages of hydration. The measured temperature profiles from a one-dimensional heat transfer …
-
Specific Heat and Thermodynamic Properties of Metallic Systems: Instrumentation and Analysis
A small-scale adiabatic calorimeter has been constructed as part of a larger project to study nano-particles and to facilitate specific heat measurements on samples where it is difficult to obtain enough material to run on the current large-scale adiabatic apparatus. This calorimeter is designed to …
-
Reaction of Lignite and Oxygen at Low Temperature: Heat of Reaction and Rate of Oxygen Consumption
… passing oxygon throu^x a prepared eanple la an adiabatic calorimeter and aaaaurlag the t®aperatare riee and oxygen eoasuaed foe* a given time*¥h« heat of oxidation asrooared to increase vith incroaninr, tersnerature. At 20* C, value© vera sporadic and ramiod down to 23.550 ^j|2^83n2 compared to …
Page 1 of 2