Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 31 for “"Adiabatic demagnetization"”
-
Adiabatic demagnetization apparatus for nuclear orientation
… hundredth of a Kelvin by thermal contact with an adiabatically demagnetized paramagnetic salt pill. The apparatus was designed for performing nuclear orientation experiments. This thesis describes the construction of the apparatus and experimental tests studying the nuclear orientation of (60)Co …
-
Design of an Adiabatic Demagnetization Cryostat for Ultrasonic Studies.
… for isothermal magnetization and subsequent adiabatic demagnetization of a paramagnetic salt to reach temperatures as low as 0,06°K. The cryostat is to be used for ultrasonic attenuation studies of superconducting metals with low transition temperatures. The low temperature is necessary to …
-
Magnetic measurements on chrome-cesium alum below 1° K
… function of entropy at temperatures obtained by adiabatic demagnetization. Measurements were made with a moving-coil apparatus in zero external field using a small (.9 gauss) measuring field; measurements were also made with a conventional ballisticgalvanometer apparatus, …
-
Properties of high current superconducting magnet coils
In connection with the fabrication of an adiabatic demagnetization cooling device, the properties of some high current superconducting magnet coils have been studied. This thesis includes investigations of critical current vs. magnetic field for Nb(3)Zr coils wound with several packing fractions. …
-
Gamma ray anisotropies in antiferromagnetic crystals of MnSiF₆.6H₂0 and CoC1₂.6H₂0
By the technique of adiabatic demagnetization, paramagnetic salts may be cooled to temperatures less than .1°K. By good thermal contact between crystals and paramagnetic salts, the antiferromagnetics MnSiF₆.6H₂0 and CoC1₂.6H₂0 were cooled to temperatures at which the hyperfine interaction energy of …
-
N.M.R. below 1 K with a S.Q.U.I.D. magnetometer.
… to cool the experimental stage to 1.3K and adiabatic demagnetization of a paramagnetic salt to further cool the stage to 240 mK. The N.M.R. spectrum of lithium in a crystal of lithium niobate was also studied at 4.2K. The quadrupole coupling constant e2qQ/h was measured to be 52 +/- 1 KHz …
-
A new method for the investigation of film flow below one degree in liquid helium.
… 0.6°K, The lower temperatures were obtained by adiabatic demagnetization techniques. Chapter III is a report of such experimentation. The results obtained are much like those of Ambler and Kurti, 1952, and support their contention that film flow rates do increase with decreasing temperatures in …
-
Ferromagnetic Spin Systems Probed in Millikelvin Regime Using Microwave Spectroscopy
… and deposition, which were then placed inside an Adiabatic Demagnetization Refrigerator (ADR) and cooled down to milliKelvin temperatures. Using this fabrication technique, it was possible to remove the Gallium Gadolinium Garnet (GGG) substrate commonly used in YIG thin films, which has been shown …
-
Setup of Dry Cryostat for Measurements on Superconducting Microwave Resonators
… The setup involved the removal of an adiabatic demagnetization refrigerator (ADR) and replacing it with a dilution refrigerator system. The modified cryostat is able to provide continuous cooling power, enabling greater flexibility over the ADR in the type of low temperature …
-
Setup and Design of a Cryogenic Testing Station with Focus on Characterization of Superconducting Devices
… included modifying an existing SHASTA model 106 Adiabatic Demagnetization Refrigerator (ADR) by adding a new physical support structure to allow for more weight to be added to the cryostat’s testing stages, as well as custom pieces of electronics, such as a room temperature programmable current …
-
Superconducting Properties of the NbN and TiN alloy system.
… used: four-point probe DC measurements in an adiabatic demagnetization refrigerator (ADR) were used for Tc and ΔTc measurements, and a magnetic properties measurement system (MPMS) which employs a SQUID magnetometer was employed for Tc and Hc measurements. Values of Tc ranged from 4.2 K for …
-
A study of some non-hydrated paramagnetic substances for cooling below 1°K.
… for appreciable lowering of the temperatures by adiabatic demagnetization. The specific heat of a well behaved pure substance is proposed as a resonably sensitive thermometric standard. Its usefulness is illustrated by calibrating a secondary thermometer using the proposed method. The …
-
The development of a 10 mK refrigeration system for space
… shield temperatures of 150 K, 20 K and 4 K, the adiabatic demagnetization refrigerator (ADR) proposed cools from a bath temperature of 4 K to 10 mK. The maximum amount of time for which the ADR can maintain this temperature is around 145 hours with no cooling power on the detector stage. This …
-
Some properties of paramagnetic salts at very low temperatures
… heats above 1°K were measured in terms of the adiabatic and isothermal susceptibilities, from the ratio of which the specific heat at constant magnetisation can be calculated thermodynamically. These susceptibilities can be measured with the Hartshorn bridge using suitable audio frequencies. …
-
Hall Resistance Characterization of Thermoelectric Materials; Subgap Leakage Measurement of Josephson Junctions
… this thesis, the junctions are mounted in a dry adiabatic demagnetization refrigerator (ADR) and cooled down to as low as 130 $mK$. A voltage-bias circuit and a current-bias circuit for the measurement are designed and used. A NbTi superconducting magnet is made to provide magnetic fields to …
-
Investigating the Magnetic Properties of Frustrated Spin Systems: Square and Breathing Pyrochlore Lattices
… applications in magnetocaloric cooling (MCE) and adiabatic demagnetization refrigeration (ADR). A key achievement of this research is the successful synthesis of single crystals—essential for probing anisotropic magnetic systems. We report the first high-quality single crystals of these materials, …
-
Magnon Bose-Einstein Condensate as a Probe of Topological Superfluid
… is cooled to ultra-low temperatures in rotating adiabatic demagnetization refrigerator. Careful characterization of the creation and the decay of the trapped magnon BEC reveals nonhydrodynamic spin diffusion as the main temperature-dependent source of relaxation. Using this property, we suggest …
Page 1 of 2