Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 46 for “"Admittance control"”.
-
Unifying Impedance and Admittance Control for Improved Robot Interaction
… for unifying different types of Interaction Controllers in terms of force sensor and modelling uncertainty sensitivity. This reduces the selection of Impedance Control, Admittance Control, or other variants to a selection along a spectrum defined by a trade-off between these sensitivities. …
-
A hybrid system approach to impedance and admittance control
Impedance Control and Admittance Control are two different implementation methods that are used to achieve the same control objective of producing a desired relationship between applied force and displacement of a robotic system interacting with an environment. Due to the difference in …
-
Autonomous Loading of Fragmented Rock: Admittance Control for Robotic Digging
An admittance-based controller for autonomously digging in fragmented rock piles was developed and tested by using a 1 t surface loader, and a 14 t Atlas Copco Load-Haul-Dump (LHD) vehicle. This admittance-based Autonomous Loading Controller (ALC) had superior consistency over both digging at …
-
Categorizing Admittance Control Parameters for the Ranger 8-DOF Tele-operated Space Manipulator
Position-based admittance control of a robotic manipulator is a strategy that allows the manipulator to achieve compliance without sacrificing positional accuracy or modifying the underlying position controller. Desired manipulator stiffness and damping can be specified so that the tool tip behaves …
-
Admittance control of the intelligent assist robot manipulator for people with duchenne muscular dystrophy
… robotic device. This design involves the use of admittance control as the interface for the intelligent Assist Robot Manipulator (iARM). A thorough qualitative and quantitative analysis of the prototype is performed, the results of which are presented. The quantitative analysis focuses on the …
-
A novel approach to user controlled ambulation of lower extremity exoskeletons using admittance control paradigm
… to initiate a gait but not the ability to control the stride amplitude (height), stride frequency or stride length, and hence restricting users' ability to navigate across different surfaces and obstacles that are commonly encountered in the community. Most current exoskeletons do not have …
-
Realization of dynamixel servo plant parameters to improve admittance control for a compliant human-robot interaction
In theory, admittance control offers a very effective method of implementing smooth human-robot interaction. It allows the user's applied force to control the movement of a powerful robot as if the robot were a small, passive mass. However, the real-world application of admittance control faces …
-
A novel approach to increase upper extremity active range of motion for individuals with duchenne muscular dystrophy using admittance control
… devices for individuals with DMD by using admittance control. Admittance control is an inherently safe and intuitive robotic control paradigm that maps the user's applied force to the motion of a robot. It is hypothesized that a motorized arm support utilizing the admittance control …
-
Force-Based Control for Reduced Deformation Human-Robot Transport of Flexible Objects
… without relying on external sensing in the control loop. The challenge is that, unlike rigid-object co-transport, the dynamics of a flexible object distort the interaction force sensed by the robot. As a result, standard admittance control can lead to reduced gain margins, increased …
-
Stability and Performance Improvement in Haptic Human-Robot Interaction
… encountered, a human operator often attempts to control the oscillation by stiffening their arm, which leads to a stiffer system with more instability. Robot co-worker controllers must account for this issue. In this work we set out to 1) understand the association between neuromuscular …
-
Comprehensive Control Strategies for a Seven Degree of Freedom Upper Limb Exoskeleton Targeting Stroke Rehabilitation
In this dissertation control algorithms are developed and tested for the EXO-UL7 towards a control strategy for stroke rehabilitation. EXO-UL7 is a seven degree of freedom (Dof) powered upper limb exoskeleton that was initially designed at the University of Washington and further refined at the …
-
Robotic Ultrasound Tomography and Collaborative Control
… convex contour tracking scheme, while impedance control enforces its gentle contact with the patient’s pubic region for capturing the transmission ultrasound slices needed for limited-angle tomographic reconstruction. TRUS rotation was induced by joystick control for precision during testing, …
-
Admittance and impedance haptic control for realization of digital clay as an effective human machine interface (HMI) device
… prototype and implements 2 commonly used haptic control methods, the admittance control and the impedance control. For implementing the admittance control, actuator displacement and velocity controllers and a proportional integral observer (PIO) are designed. The model-based unknown input …
-
Force Estimation Based Compliance Control of a Two Link Harmonically Driven Robotic Manipulator
… of the manipulator's kinematics. Adaptive control is used to tune the parameters of the robot's modeled dynamics, while adaptive radial basis function (RBF) neural networks are used to learn the friction dynamics. Admittance control without force sensing is attempted on a two degree of …
-
Stability analysis and robust control of human intention-based physical human-robot interaction.
… adaptation is usually realized by changing admittance parameters according to human interaction in physical human-robot interaction (pHRI). However, admittance parameters inferred from human intention may result in instability. This dissertation conducts a fundamental and systematic study on …
-
Development of a Safety-Oriented Interaction Strategy and Compliant Limb Sensor System for a Gait Rehabilitation Robot
… limb sensor (CLS) and yields using a zero force controller that directly feeds back CLS deformation. Using a 1DoF LTI model, controller stability was proven and the reduction of impedance and CLS deformation was analyzed. The effect of nonlinearities on the controller was simulated. Stiction was …
-
Desarrollo e implementación de un exoesqueleto de miembro inferior en actividades de la vida diaria
… involved in the implementation of the control strategies is presented, based on an admittance control and an impedance control that takes into account the pHRI.Finally, it is shown the experimental design made for the characterization of the performance system; preliminary tests of the …
-
Disturbance observer based closed loop control of haptic interfaces
Traditionally, control of haptic interfaces is achieved using open-loop impedance or admittance control. During open-loop control, the quality of haptic feedback is limited by the dynamics of the haptic device. Further improvements in quality of the haptic feedback require the use of closed-loop …
-
Robot dynamic path modification via multi-sensor data tracking
… proposes and validates experimentally nonlinear control strategies for a six-axis industrial robot Meca500 from Mecademic company using two approaches. The first approach aims to provide a precise dynamic trajectory tracking in Cartesian velocity space in the presence of parameter uncertainty and …
Page 1 of 3