Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 28 for “"Adsorptive stripping voltammetry"”

  1. Square wave cathodic (adsorptive) stripping voltammetry of selenium, arsenic, vanadium, and molybdenum.

    … has been investigated with square wave cathodic stripping voltammetry (SWCSV) and square wave adsorptive stripping voltammetry (SWAdSV). Se(IV) and As(III) form intermetallic compounds with copper and are deposited at a hanging mercury drop electrode (HMDE). V(V) and Mo(V) form …

    wvu Repository record for Square wave cathodic (adsorptive) stripping voltammetry of selenium, arsenic, vanadium, and molybdenum. (opens in a new tab)

  2. Graphene-modified pencil graphite mercury-film electrodes for the determination of trace metals by cathodic adsorptive stripping voltammetry

    … focuses on the simple, fast and highly sensitive adsorptive stripping voltammetry detection of Nickel and Cobalt complexed with DMG and Nioxime respectively at a Reduced Graphene Oxide modified pencil graphite electrode in water samples. This research as well demonstrates a novel electrochemically …

    western-cape Repository record for Graphene-modified pencil graphite mercury-film electrodes for the determination of trace metals by cathodic adsorptive stripping voltammetry (opens in a new tab)

  3. Determination of heavy metals at the electrochemically reduced graphene oxide mercury film electrode (ERGO-HgF-PGE) using adsorptive stripping voltammetry

    … (cupferron) as complexing agent by square-wave adsorptive cathodic stripping voltammetry (SW-AdCSV). The technique is based on the adsorption of cupferron- metal ion complexes onto the surface of the ERGO-HgFPGE at 0.1 V for 60 s carried out in 0.1 M acetate buffer solution (pH 4.6). The …

    western-cape Repository record for Determination of heavy metals at the electrochemically reduced graphene oxide mercury film electrode (ERGO-HgF-PGE) using adsorptive stripping voltammetry (opens in a new tab)

  4. Determinação voltamétrica de triclocarban e carbendazim em produtos de higiene pessoal e água potável

    … of voltammetric methods, direct VOQ and adsorptive stripping voltammetry. For adsorptive stripping voltammetry, the linear response range was from 1.8 to 21 × 10-9 mol L-1 with a detection limit (LD) of 3.2 × 10-10 mol L-1, 1,000 times smaller than the LD obtained by direct VOQ. The …

    brazil-ufpb Repository record for Determinação voltamétrica de triclocarban e carbendazim em produtos de higiene pessoal e água potável (opens in a new tab)

  5. Microfluidic graphenised-paper electroanalytical devices (μGPED) for adsorptive cathodic stripping voltammetric detection of metal contaminants

    … of illnesses. Over the last two decades, adsorptive stripping voltammetry (AdSV) has emerged as a superior detection method over common analytical techniques due to its low-cost instrumentation, unskilled labour and ability to detect a wide range of analytes.

    western-cape Repository record for Microfluidic graphenised-paper electroanalytical devices (μGPED) for adsorptive cathodic stripping voltammetric detection of metal contaminants (opens in a new tab)

  6. Electroanalysis of Metals in Biological and Environmental Samples at Bismuth Electrodes

    … analyzed for chromium content by catalytic adsorptive stripping voltammetry at a bismuth film electrode. The concentration of chromium was determined to be 6.0 " 0.3 parts per billion (ppb). A bismuth bulk electrode was designed and characterized, and was found to be useful in the analysis …

    utk-theses Repository record for Electroanalysis of Metals in Biological and Environmental Samples at Bismuth Electrodes (opens in a new tab)

  7. Studies on direct and indirect electrochemical immunoassays

    … such proteins, studies were carried out on the adsorptive stripping voltammetry of the immunoglobulin fragments, F(ab1 )2 and Fab. The globular proteins avidin and streptavidin, were then studied as these were similarly constructed proteins, except avidin had a disulphide bond, and streptavidin …

    dcu Repository record for Studies on direct and indirect electrochemical immunoassays (opens in a new tab)

  8. Electroanalytical and chromatographic investigations of the antineoplastic agent cisplatin and related species

    … amino acid cystine was then investigated using adsorptive stripping voltammetry (AdSV). A mechanism was proposed for the electroreduction of these biologically important molecules. A fractional coefficient for the binding of cisplatin to HSA at pH 7.4 was calculated to be 0.32. The reactivity of …

    dcu Repository record for Electroanalytical and chromatographic investigations of the antineoplastic agent cisplatin and related species (opens in a new tab)

  9. Tratamento de solo contaminado com Pb2+ empregando remediação eletrocinética e barreiras reativas

    … approach for monitoring Pb2+ concentration, adsorptive stripping voltammetry (AdSV) technique was used, obtaining acceptable confidence and good sensitivity for the concentration of Pb2+ with LOD about 0.1 mg L−1 . Phytotoxicity tests showed that the ER process could be useful as a treatment …

    brazil-ufrn Repository record for Tratamento de solo contaminado com Pb2+ empregando remediação eletrocinética e barreiras reativas (opens in a new tab)

  10. New Electrochemical and Optical Detection Methods for Biological and Environmental Applications

    … for Cr and V detection. While catalytic adsorptive stripping voltammetry (CAdSV) has been used to detect Cr and V, little is known about the process. The mechanisms of CAdSV have been probed to provide a better understanding of its exceptional sensitivity and selectivity.</p> <p>Near-real …

    utk-theses Repository record for New Electrochemical and Optical Detection Methods for Biological and Environmental Applications (opens in a new tab)

  11. Determinação simultânea de Cu, Pb, Cd, Ni, Co e Zn em etanol combustível por voltametria de redissolução adsortiva e calibração multivariada.

    … and Zn at trace level using differential pulse adsorptive stripping voltammetry (DPAdSV). A hanging drop mercury electrode (HDME) was employed as working electrode. The calibration set was assembled by using a Brereton s design, performing 25 replicate mixtures. The different linear ranges were …

    brazil-ufpb Repository record for Determinação simultânea de Cu, Pb, Cd, Ni, Co e Zn em etanol combustível por voltametria de redissolução adsortiva e calibração multivariada. (opens in a new tab)

  12. Determination of Chromium(VI), Vanadium(V), Selenium(IV) and Zinc(II) in the City of Cape Town's potable water by stripping voltammetry at boron doped diamond electrodes

    … method for determining these metals is by adsorptive stripping voltammetry, using a thin mercury film electrode with a glassy carbon support. This voltammetric method is used for quantitative determination of specific ionic species. Because of mercury's toxicity it is not really favoured …

    western-cape Repository record for Determination of Chromium(VI), Vanadium(V), Selenium(IV) and Zinc(II) in the City of Cape Town's potable water by stripping voltammetry at boron doped diamond electrodes (opens in a new tab)

  13. Novel preconcentration techniques for the determination of trace metal ions in environmental matrices

    … 90 % recovery was achieved. Surfactant enhanced adsorptive stripping voltammetry for trace level determination of aluminium in water and soil samples is reported in chapter 5. This electroanalytical preconcentration method allowed the determination of aluminium as its Solochrome Violet RS (SVRS) …

    dcu Repository record for Novel preconcentration techniques for the determination of trace metal ions in environmental matrices (opens in a new tab)

  14. Κατασκευἠ και εφαρμογές απορριπτόμενων αισθητήρων για τον ηλεκτροχημικό προσδιορισμό οργανικών ενώσεων

    … in water samples by differential pulse cathodic voltammetry. The limits of quantification in 3 different water matrices were in the range 1.1-2.2 μmol L-1. Using a simple solid-phase extraction procedure, the limits of quantification were in the range 0.021-0.025 μmol L-1 while the recoveries of …

    greece Repository record for Κατασκευἠ και εφαρμογές απορριπτόμενων αισθητήρων για τον ηλεκτροχημικό προσδιορισμό οργανικών ενώσεων (opens in a new tab)

  15. The development of some electrochemical detection systems using microelectrodes and their application to biomedical analysis

    … fluids. The advantages of microelectrodes and adsorptive stripping voltammetry were combined by developing a mercury thin film ultramicroelectrode using a carbon fibre substrate. Using phase-selective AC stripping voltammetry, a very sensitive technique was developed for the analysis of …

    dcu Repository record for The development of some electrochemical detection systems using microelectrodes and their application to biomedical analysis (opens in a new tab)

  16. Semi-circular sweep voltammetry for electroanalysis

    … on electroanalysis using semi-circular sweep voltammetry. This method is particularly developed for analytes which show significant difficulties when analysed using conventional voltammetry. <p>The fundamentals of electrochemistry and the principles of electrochemical methods are introduced in …

    oxford Repository record for Semi-circular sweep voltammetry for electroanalysis (opens in a new tab)

  17. Electrochemical studies at carbon-based electrodes

    … electrode to be tuned to exhibit diffusional or adsorptive voltammetry at oxidised and hydrogenated BDD interfaces respectively. Adsorption effects were also observed on the modified electrode leading to significant pre-concentration of the analyte onto the nanocarbon and a corresponding lowering …

    oxford Repository record for Electrochemical studies at carbon-based electrodes (opens in a new tab)

  18. Low-cost analytical tools for compositional analysis of particulate matter

    … with highly selective chemical precipitation for adsorptive stripping voltammetry. The approach gave LOD of 1.0 and 5.0 μg L-1 for Co and Ni, respectively. Finally, Bi-modified CSPEs were used to determine Co and Ni in aerosol samples. The amount of Co and Ni in the samples determined using the …

    colostate Repository record for Low-cost analytical tools for compositional analysis of particulate matter (opens in a new tab)

  19. Κατασκευή και εφαρμογές μικροαισθητήρων για χημική ανάλυση

    Stripping voltammetry (SV) has proved a powerful technique for the determination of trace metals in samples of environmental, clinical and industrial origin, due to its high sensitivity, low cost, rapidity and the potential for multi-element determinations. Mercury film electrodes (MFEs) and the …

    greece Repository record for Κατασκευή και εφαρμογές μικροαισθητήρων για χημική ανάλυση (opens in a new tab)

  20. Novel Electrochemical Detections of Biologically and Environmentally Relevant Substances

    <p>Development and studies of new electrochemical methods for the detection of various biologically and environmentally relevant substances are the focus of this dissertation. A dual amperometric sensor, capable of the simultaneous, real-time determination of NO and O,2, has been developed and …

    utk-theses Repository record for Novel Electrochemical Detections of Biologically and Environmentally Relevant Substances (opens in a new tab)

Page 1 of 2