Characterization of errors and predictability of disease using the Advia 120 hematology analyzer leukocyte differential
… scatterplots as novel data delivery systems. The Advia 120 hematology analyzer leukocyte differentiation method produces several novel parameters, including two channel (perox and baso) cytograms and several indicators of intracellular myeloperoxidase activity. These parameters can be …
-
Platelet count and plateletcrit in Cavalier King Charles Spaniels and Greyhounds using the Advia 120/2120
… disease to the University of Minnesota (Advia 2120) and Auburn University Teaching Hospitals (Advia 120) over a 3 year period. Results: A canine plateletcrit reference interval of 0.129 – 0.403 % was established. None of the four sample groups were found to have significantly more …
-
Validation Of Complete Blood Count Methodology, And Determination Of The Relationship Between Endoparasite Load And Erythrocyte Values In New World Camelids
… by automated hematology analyzers such as the ADVIA 120/2120 requires isovolumetric cell sphering; however, camelid RBC membranes are resistant to shape change. There are no published reports of method validation for hematologic analysis of camelid blood. <i>Mycoplasma haemolamae</i> and …
-
The study of Platelet Function using Flow Cytometry to Assess Effectiveness of Platelets Transfusion Therapy
… CCI and platelet parameters were performed with ADVIA 120(Bayer, USA). RESULTS: 1) Reference values for the percentages of expression of PAC1 and CD62P in platelets, respectively, were 0.1~12.5% and 0.0~4.7% at the resting status, 65.3~92.4% and 39.0~75.7% at the addition of 20 μM ADP, 68.1~93.1% …
-
Επίδραση φυσιολογικών και παθολογικών παραγόντων σε αιματολογικές παραμέτρους των μηρυκαστικών
… in blood smears with those obtained by ADVIA 120 hematology analyzer and the validation of the appropriate correction factors for the manual technique, as well as the assessment of two suggested factors for platelet calculation in blood smears in sheep. In order to generate the …
-
Mελέτη της επίδρασης της μυκοτοξίνης ζεαραλενόνης στις αιματολογικές, βιοχημικές και ορμονικές παραμέτρους, την οξειδοαναγωγική κατάσταση του αίματος, καθώς και σε παραμέτρους εκτίμησης του σπέρματος αρσενικών κονίκλων
… Complete blood counts were carried out on ADVIA 120 (Siemens Healthcare Diagnostics, USA), while Giemsa-stained smears were also examined. Sera samples were assayed in the analysers Flexor E (Vital Scientific NV, The Netherlands) and AVL 9180 Electrolyte Analyser (Roche Diagnostics, …
-
Μελέτη της μεταβολής των αιματολογικών, βιοχημικών και ορμονικών παραμέτρων, καθώς και της οξειδοαναγωγικής κατάστασης του αίματος των κριών κατά την αναπαραγωγική δραστηριότητα
… after T0). Complete blood count was performed on Advia 120 (Siemens Healthcare Diagnostics, USA), while the cytological examination of blood smear was followed. The analyzers Flexor E (Vital Scientific N.V., The Netherlands) and AVL 9180 Electrolyte Analyzer (Roche Diagnostics, Belgium) were used …