  1. Evaluation of an Aerodynamic Particle Sizer With Certified Polydisperse Test Dusts

    The Aerodynamic Particle Sizer (APS) is a near real time laser particle sizer that counts and sizes particles in the range of 0.5 /xm to 3 0 /xm, which makes it ideal for measuring the particle size distribution of fly ash from coal combustion. While the APS has proven to be a valuable instrument …

    nodak Repository record for Evaluation of an Aerodynamic Particle Sizer With Certified Polydisperse Test Dusts (opens in a new tab)

  2. The seasonality of aerosol properties in Big Bend National Park

    … (TDMA) and, during the spring and summer, an aerodynamic particle sizer (APS), to characterize the seasonal variability of the Big Bend regions aerosol optical properties. Mass extinction efficiencies and relative humidity scattering enhancement factors were calculated for both externally and …

    tamu Repository record for The seasonality of aerosol properties in Big Bend National Park (opens in a new tab)

  3. Development and Evaluation of a Real-Time Mid-Infrared Photoacoustic Spectrometer for Measuring Silica and Other Mineral Dust Mass Concentrations

    … particulate matter concentrations, while a TSI Aerodynamic Particle Sizer (APS) was used to record size distributions. The accuracy of this method was determined by comparing the results to the NIOSH filter-based FTIR technique for RCS mass concentration measurement. The filter-based FTIR …

    unr Repository record for Development and Evaluation of a Real-Time Mid-Infrared Photoacoustic Spectrometer for Measuring Silica and Other Mineral Dust Mass Concentrations (opens in a new tab)

  4. Using Sensors to Investigate the Effectiveness of Portable Air Filtration for Reducing Particle Exposures: Implications for Community Congregate Settings

    … calibrating the performance of low-cost optical particle sensors, 2) Evaluate the real-world effectiveness of portable HEPA air cleaners (HEPA PACs) in reducing indoor particle levels in community congregate settings, while assessing usage patterns and factors influencing their efficacy, and 3) …

    washington Repository record for Using Sensors to Investigate the Effectiveness of Portable Air Filtration for Reducing Particle Exposures: Implications for Community Congregate Settings (opens in a new tab)

  5. Generation of graphite particles by rotational/spinning abrasion and their characterization

    Graphite particle generation by inter-pebble abrasion and by abrasion of pebbles with the containment vessel during operation of a Pebble Bed Reactor (PBR) is an issue of interest in the safety analysis of this class of Very High Temperature Reactor (VHTR). To understand particle generation, we …

    missouri Repository record for Generation of graphite particles by rotational/spinning abrasion and their characterization (opens in a new tab)

  6. Radionuclide Surrogate Aerosolization, Resuspension, and Suppression

    … across size, surface, and mode of resuspension. Particle size distribution was measured using an aerodynamic particle sizer and the resuspended particles were collected with the wetted wall cyclone and quantitated using inductively coupled plasma mass spectrometry. This testing is later repeated …

    tamu Repository record for Radionuclide Surrogate Aerosolization, Resuspension, and Suppression (opens in a new tab)

  7. Optimizing the development and analysis of solution based metered dose inhalers

    … evaluation tool; the Model 3320 series Aerodynamic Particle Sizer (APS) used in conjunction with Model 3320 Impactor Inlet was evaluated for analysis of solution metered dose inhalers. The Model 3320 APS series provides rapid aerodynamic size distribution data and coupled with Model 3306 …

    arizona-thes Repository record for Optimizing the development and analysis of solution based metered dose inhalers (opens in a new tab)

  8. Development of an electronic sensor for engine exhaust particulate measurements

    … meter, gravimetric filter measurements, an aerodynamic particle sizer and a light scattering nephelometer. The output of the sensor compared well with exhaust opacity for the transient measurements and to filter mass loading for the steady-state tests. Various parameters that affect the …

    texas Repository record for Development of an electronic sensor for engine exhaust particulate measurements (opens in a new tab)

  9. Automatic Particle Counting Using An Acoustic Transducer

    Aerosol particle detection and determination finds important applications in the commercial, military and aerospace sectors. Monitoring of clean room environments, and spacecraft integration and check out facilities are some of the most important aplications. In the early days test filters were …

    ucf Repository record for Automatic Particle Counting Using An Acoustic Transducer (opens in a new tab)

  10. Performance of a High Volume PM2.5 Sampler

    … (PM) is a complex mixture of extremely small particles suspended in the air. PM_(2.5) is the fraction of particles suspended in the air with diameters that are nominally 2.5 μm and smaller. For regulatory purposes, PM_(2.5) concentrations can be measured by a Federal Equivalent Method (FEM) …

    tamu Repository record for Performance of a High Volume PM2.5 Sampler (opens in a new tab)

  11. Dispersion of Oil Spills by Breaking Waves

    … of turbulence have been quantified using Particle Image Velocimetry (PIV). The measurements of the droplet size measurements have been performed in situ using digital inline holography at two magnifications. All early (2-10s) droplet size distributions display two distinct size ranges with …

    jhu Repository record for Dispersion of Oil Spills by Breaking Waves (opens in a new tab)

  12. Errors in sampling particulate flows with a 10-mm Dorr-Oliver cyclone separator.

    … 10mm Dorr-Oliver nylon cyclone as a particle preclassifier for respirable dust sampling was experimentally determined relative to an isokinetic sampler (sampling efficiency) and an inlet simulator sampler (penetration). A TSI Aerodynamic Particle Sizer (APS 3310) and a Marple …

    wvu Repository record for Errors in sampling particulate flows with a 10-mm Dorr-Oliver cyclone separator. (opens in a new tab)

  13. Usinage à haute vitesse et à sec des alliages d'alluminium : aspects écologiques, thermomécaniques et dynamiques

    … utilisant deux spectromètres : Scanning Mobility Particle Sizer spectrometer et Aerodynamic Particle Sizer spectrometer Le modèle permet de prédire les émissions de poussière pour des conditions de coupe données et de confirmer que la majorité de particules générées est causée par les déformations …

    ets-quebec Download PDF for Usinage à haute vitesse et à sec des alliages d'alluminium : aspects écologiques, thermomécaniques et dynamiques (opens in a new tab)

  14. Laboratory Evaluation of Low to Medium Cost Particle Sensors

    … of commercial laser light scattering based particle sensors. To accomplish this, eight were evaluated against a reference instrument and the relationship was modeled. Afterwards, a custom apparatus with improved calibration was developed for particulate monitoring. The eight commercial …