Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 12 of 12 for “"Ag/AgCI"”.

  1. Design, Product Development and Risk Assessment of Tin (sn) ring electrodes as a substitute to Silver-Silver Chloride (AG AgCI) ring electrodes for High Definition transcranial Direct Current Stimulation (HD-tDCS)

    … alternative to sintered Silver-Silver Chloride (Ag|AgCl) ring electrodes for High Definition – transcranial Direct Current Stimulation (HD-tDCS). Throughout our initial bench top testing of tin electrodes in combination with a ‘conductive electrode gel’, the passing of a 2mA direct current on …

    cuny Repository record for Design, Product Development and Risk Assessment of Tin (sn) ring electrodes as a substitute to Silver-Silver Chloride (AG AgCI) ring electrodes for High Definition transcranial Direct Current Stimulation (HD-tDCS) (opens in a new tab)

  2. Cathodic Protection of Corroded Pre-stressed Tendons

    … corrosion and subsequent concrete damage. However, concerns exist about the ability of CP to avert deterioration in pre-stressed structures due to hydrogen generation and subsequent embrittlement of the tendons. This research investigates the performance of pre-stressed steel tendon …

    sheffield-hallam Repository record for Cathodic Protection of Corroded Pre-stressed Tendons (opens in a new tab) Download PDF for Cathodic Protection of Corroded Pre-stressed Tendons (opens in a new tab)

  3. Microfluidic Reference Electrode for Use in BioFET Sensor Systems

    <p>Biosensors, used in medical diagnostics, increasingly use genomic information (DNA) to rapidly and accurately determine the species present in the sample. Since, the DNA inherently has a negative charge, electrical methods provide a direct technique to sense it. This transduction has been …

    mcmaster Repository record for Microfluidic Reference Electrode for Use in BioFET Sensor Systems (opens in a new tab)

  4. Formaldehyde yields from methanol electrochemical oxidation on platinum and supported catalysts

    … charge at 0.2-0.3 V (vs. a KCI saturated Ag/AgCI reference electrode) for methanol concentrations between 15 mM and 0.3 M in 0.1 M perchloric acid. The formaldehyde yields were lower at more positive potentials, as other oxidation pathways became dominant. However, the rate of formaldehyde …

    ttu Repository record for Formaldehyde yields from methanol electrochemical oxidation on platinum and supported catalysts (opens in a new tab)

  5. Electrochemical and transmission infrared spectroscopic studies of methanol oxidation reactions at platinum and platinum-ruthenium fuel cell catalysts

    … electrochemical oxidation was studied. The average yields of CO2 are close to 100 % across the range of potentials studied. The experimental results demonstrate the ex situ technique has sufficient sensitivity to determine CO2 in electrolyzed samples following 180 s reaction time, and also …

    ttu Repository record for Electrochemical and transmission infrared spectroscopic studies of methanol oxidation reactions at platinum and platinum-ruthenium fuel cell catalysts (opens in a new tab)

  6. Galvanic interaction between chalcopyrite and pyrite during atmospheric leaching

    … potential should be controlled above 455 mV vs Ag/AgCI, although it is difficult to comment on the optimal range due to gas liquid mixing limitations at higher potentials. Initial acid content of 1.8 kg per kg concentrate and a leach temperature of 80°C were also selected for best results. …

    ubc Repository record for Galvanic interaction between chalcopyrite and pyrite during atmospheric leaching (opens in a new tab) Download PDF for Galvanic interaction between chalcopyrite and pyrite during atmospheric leaching (opens in a new tab)

  7. Effects of isometric elbow flexion on electromyographic spike analysis

    … (46 males and 50 females) ranging in age (18-35 years), generated three 5-second isometric step contractions at each force level of 40, 60, 80, and 100 percent of maximal voluntary contraction (MVC). The presentation of the contractions was balanced across subjects. The right arm of …

    brock Repository record for Effects of isometric elbow flexion on electromyographic spike analysis (opens in a new tab)

  8. Development and characterization of novel biosensors utilizing plant tissue materials and intact chemoreceptor structures

    … of the amine was monitored at 0.9 V vs. Ag/AgCI under steady-state conditions using this sensor. Easy construction, reliability of the data, reusability and shorter response times are some of the advantages of this sensor. Receptor-based biosensors using chemosensing structures from …

    hawaii Repository record for Development and characterization of novel biosensors utilizing plant tissue materials and intact chemoreceptor structures (opens in a new tab)

  9. Application of microfabrication in electrochemical sensing.

    … sensing have been evaluated. Specific advantages of the micro fabrication approach include the capability to create an intelligent design containing features such as redundant sensing electrodes, on-chip reference and auxiliary electrodes, and in situ electrode regeneration/calibration. One …

    louisville Repository record for Application of microfabrication in electrochemical sensing. (opens in a new tab)

  10. Size- and shape-dependent electrochemistry of gold nanoparticles.

    … shapes. We synthesized Au nanoparticles with average diameters ranging from 5 to 45 nm by a chemical seed-mediated growth method and electrostatically attached them to amino-functionalized glass/ITO electrodes. Linear sweep voltammograms (LSVs) obtained on electrodes coated with Au NPs in 0.01 M …

    louisville Repository record for Size- and shape-dependent electrochemistry of gold nanoparticles. (opens in a new tab)

  11. The coordination and organometallic chemistry of ruthenium porphyrin species

    … HX acids in C₆H₆ yields the corresponding paramagnetic RuIV(porp)X₂complexes, where porp = the 2, 3, 7, 8, 12, 13, 17, 18- octaethylporphyrin dianion(OEP), L= pyridine(py), X= Cl; and porp = the 5, 10, 15, 20- tetramesitylporphynn dianion(TMP), L =CH₃CN, X= Cl or Br. The 3 day reactions ( at …

    ubc Repository record for The coordination and organometallic chemistry of ruthenium porphyrin species (opens in a new tab) Download PDF for The coordination and organometallic chemistry of ruthenium porphyrin species (opens in a new tab)

  12. Ανάπτυξη προηγμένων μετρητικών συστημάτων και τεχνικών για ηλεκτροφυσιολογικά φαινόμενα

    Στην παρούσα διδακτορική διατριβή προτείνεται η ανάπτυξη ενός προηγμένου μετρητικού συστήματος για τη διερεύνηση ηλεκτροφυσιολογικών φαινομένων σε φυτικούς οργανισμούς. Κάθε ζωντανός οργανισμός παράγει διάφορους τύπους ενδοκυτταρικών και μεσοκυττάριων ηλεκτρικών σημάτων τα οποία αξιοποιούνται …

    greece Repository record for Ανάπτυξη προηγμένων μετρητικών συστημάτων και τεχνικών για ηλεκτροφυσιολογικά φαινόμενα (opens in a new tab)