Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 23 for “"Ag/AgCl Electrodes"”
-
Flexible film and breathable textile electrodes for electrodermal activity monitoring
… rigid and non-breathable silver/silver chloride (Ag/AgCl) electrodes, possibly in combination with gels and irritating adhesives. The research detailed in this dissertation is focused on advancing our understanding of the design and development of comfortable, flexible and breathable EDA …
-
Printed Tattoo Electrodes for Electrophysiological Signal Acquisition
The enhancement of medical tattoo electrodes over the past few decades have enabled them to serve as an alternative to conventional Ag/AgCl electrodes. Additive manufacturing methods can enable efficient and flexible fabrication of the tattoo electrodes, in contrast to the traditional fabrication …
-
Proton transport through non-covalently functionalized graphene
… require eliminating artifacts from bare Ag/AgCl electrodes, where AgCl particle deposition distorts intrinsic proton transport signals. With improved methods, it becomes clear that graphene’s proton conductivity is highly sensitive to interfacial chemistry. Asymmetric Nafion coatings …
-
Regulation of Rabbit Testicular Capsular Motility: The Interaction of Prostaglandins, Acetylcholine and Sympathomimetic Agents
… The effects of, and interactions among, prostaglandins (PGs) E1 and F2α testosterone, acetylcholine, epinephrine and norepinephrine were ascertained both in vitro and in vivo. All of these compounds, except for high concentrations of PGE1 and testosterone, stimulated the testicular capsule to …
-
Identificação de sistemas modelo Narx para a fadiga muscular emindivíduos sem deficiência durante contrações isométricas voluntárias
… by the EMG_800C with non - invasive surface Ag / AgCl electrodes and in the bipolar configuration. Labview software was used for the acquisition of this data and Matlab® for signal processing and identification of the system studied. The objective was to find a model that relates two measures …
-
Impedance measurement system for embryonic stem cell and embryoid body cultures
… quality assurance measurements used to stage the growth and differentiation of embryoid bodies are labor intensive and most often destructive to the cells, thus present methods are typically valid for a single time point. Bioimpedance measurements are non-invasive and non-destructive, …
-
BILAYER LIPID MEMBRANE (BLM) INTEGRATION INTO MICROFLUIDIC PLATFORMS WITH APPLICATION TOWARD BLM-BASED BIOSENSORS
… benefits that microfluidics offer are: small reagent sensing volumes, disposable packaging, mass manufacturability, device portability for field studies, and lower device cost. Novel polymer microfluidic platforms capable of both in-situ and ex-situ BLM formation are described in this work. The …
-
Clinical applications of calixarene based sodium-selective electrodes
… beginnings in the late 1960's ion-selective electrodes have rapidly become one of the most important types of chemical sensor. They are commercially available for a large variety of ions, are widely used and have been characterised thoroughly by many investigators. Having attained this level …
-
Design and Testing of a Hydrogel-Based Droplet Interface Lipid Bilayer Array System
… concepts use a base of patterned silver with Ag/AgCl electrodes patterned onto a flat polymer substrate. In one technique, photopolymerizable hydrogel is cured through a mask to form an array of individual hydrogels on top of the patterned electrodes. The other technique introduces a second …
-
Impedance-Based Detection of Tissue Using a Multi-Electrode Device
… in the epidermis. The current gold standard diagnostic technique for determining whether a lesion is cancerous involves subjectively examining suspicious lesions and performing an invasive biopsy to confirm melanoma. This method may neglect some lesions or cause scarring from biopsies that turn …
-
Modelling in vitro dissolution and release of sumatriptan succinate from polyvinylpyrrolidone-based microneedles aided by iontophoresis
… density ranging from 100 to 500 uA/cm^2 using Ag / AgCl electrodes displays increased flux with current density. At 500 uA/cm^2, a dissolving array loaded with 4.3 mg sumatriptan leads to a steady-state delivery rate of 490 ug/cm^2h with negligible lag time. In theory, a 9.58-cm^2 …
-
Carbon Nanotube Polymer Composite Based Electrodes with Ability to Adhere to Hairy Skin for Application in Electrophysiological Sensing
… measurements have applications in medical diagnosis, health care, human-machine interface, entertainment, etc. Electrodes are an important part of biopotential acquisition systems affecting the quality of recorded signals, comfort to the user, and the cost. Many conventional electrodes are …
-
Amphiphilic Additives for Modification of Biomedical Silicones
… These inks also met or exceeded recovered storage modulus (G’) and loss factor targets. In addition to the notable thixotropic properties, extensive water-driven restructuring was observed in select formulations. In the final study, PEO-SAs were assessed as dispersive additives (DSPAs) to …
-
Design and evaluation of textile electrodes for biological signal monitoring
… to fabric systems were investigated for silver (Ag)-nylon textiles. Fibre geometry and yarn twist were found to impact yarn linear resistance, and electrode contact impedance at the fabric level up to limiting values. Influencing factors at the yarn level were explained by contact between fibres …
-
DC-EEG for routine clinical use : methods and clinical impact
… the clinical significance and the potential diagnostic applications of infra-slow EEG signals have been a subject of little interest. This study was carried out in order to develop a method that would, for the first time, make routine bedside recording of DC-EEG possible, and to apply it in the …
-
Screen printed textile based wearable biopotential monitoring
… of woven textiles. These networks connect electrodes at different sites to electronics at a central location. The conductive tracks are composed of a silver polymer layer with thickness 5-10 µm entirely encapsulated in polyurethane. The durability of these printed conductive tracks is …
-
Bubble Free Electrodes for Electroosmotic Pumping
… micro fluidic pumping technique due to its advantages such as simple design, applicability to wide range of conductive fluids and favorable scaling of electrical forces. Electrodes are necessary to establish the electrical forces and hence fluid flow inside the micro channel. One of the major …
-
Postural and Load Dependent Modulation of Lower Limb H-reflex Excitability After Stroke
… from the soleus (SOL) muscle using self-adhesive Ag-AgCl electrodes. For individuals post-stroke, EMG was collected from both paretic and non-paretic limbs; for controls, recordings were taken from the right leg unless the participant indicated a preference. The tibial nerve was electrically …
-
Atividade elétrica dos músculos estabilizadores da patela em indivíduos portadores da síndrome da dor femoropatelar durante exercícios realizados no step
… The electric activity was recorded by surface (Ag/AgCl) electrodes, an EMG apparatus with 8 channels (EMG System Brazil) and a software of acquisition data AqDados 7.02. The EMG data was processed by the software Matlab 6.1 that calculated both the onset timing of the muscles and the integrated …
-
Elimination of Skin-stretch Induced Motion Artefacts from Electrocardiogram Signals
… used in clinical practice, for example to diagnose coronary artery disease or the cause of chest pain during a stress test, while the patient is running on a treadmill. Ambulatory ECG monitoring is used for long term recording of ECG signals, while the patient carries out his/her daily …
Page 1 of 2