Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 159 for “"Air Distribution"”.
-
Experimental investigation of hospital operating room air distribution
… significant fraction of SSI may be caused by airborne infectious particles. Improved or optimized room air distribution may reduce these infections by minimizing the transport of infectious particles into the surgical site. A sophisticated CFD analysis, previously conducted by researchers at …
-
NUMERICAL MODELLING OF SUPPLY OPENINGS FOR ROOM AIR DISTRIBUTION
… the introduction of numerical method in indoor air environment application more than twenty years ago, the method has gained a lot of attention as a promising method to complement the experimental and theoretical methods. However, it is not until recently that Computational Fluid Dynamic (CFD) …
-
Improving air distribution in deep-level mine ventilation systems
… is to ensure sufficient quantity and quality of airflow in the working areas of a mine. Deep-level mines are typically overventilated with poor volumetric efficiencies due to old working leakage, deteriorated stopping leakage, air being recirculated and high fan pressures. Consequently, the low …
-
Non-Iterative Technique for Balancing an Air Distribution System
Balancing an air distribution system consists primarily of measuring airflow and adjusting volume control devices to get specified airflow. Flow calculation methods are not accurate enough to ensure proper balancing by duct design alone. To assure proper balancing, dampers within an air …
-
Improving demand-side pressure of compressed air distribution networks in mines
… the literature, it was found that compressed air (CA) network inefficiencies offer enormous potential for optimisation. These studies showed that CA network inefficiencies result in low service delivery pressure being supplied to machinery, such as pneumatically operated drill rigs, pneumatic …
-
The Effect of a Supplemental Air Distribution System on Greenhouse Tomato Production
<p>The effectiveness of a supplemental internal air distribution system for closed greenhouses with dense plant canopies was evaluated. The system employed centrifugal fans and perforated ducts to move relatively warmer air from above the canopy to within the canopy. Preliminary tests demonstrated …
-
Field Evaluation of an Underfloor Air Distribution System in an Office Building
… thermal comfort in an office with an underfloor air distribution system. In an earlier study, thermal stratification, ventilation effectiveness and thermal comfort were evaluated with this arrangement, but diffusers were later relocated away from occupants and furniture. The opportunity was taken …
-
The effects of indoor jets on air distribution and human exposure to particles
Indoor jets considerably dominate air movement and distribution of temperature and velocity, as well as transport of particles and other pollutants. Indoor air temperature and velocity distribution substantially impact occupants’ thermal comfort and productivity, heat and mass transfer on indoor …
-
Empirical and human response studies of personalized ventilation combined with underfloor air distribution system
… (PV) system in conjunction with an Under Floor Air Distribution (UFAD) system (PV-UFAD) with focus on improvement of occupants? thermal comfort and inhaled air quality in an energy efficient manner. The problem of ?cold feet? and ?warm head? in conventional UFAD systems employed for cooling …
-
MODELING AND CONTROL OF PCM-BASED THERMAL ENERGY STORAGE INTEGRATED IN AIR DISTRIBUTION SYSTEMS
… off-peak hours, the system runs at a supply air temperature (SAT) below the PCM solidification point to charge the storage unit with “cooling” energy. During on-peak hours, a higher SAT is utilized so that the stored “cooling” energy can be discharged into the supply-air as a means to reduce …
-
The Effect of Primary Air Distribution on Emissions from a Natural Gas Water Heater
… N2 is introduced into the primary fuel and air flow to simulate flue gas recirculation (FGR) in order to estimate what benefit such a strategy might provide. NOx concentration in the exhaust decreases from 84 ppm to 34 ppm (at 3% dry O2) when the primary equivalence ratio is decreased from …
-
Occupant Satisfaction with Underfloor Air Distribution Systems in a Cold Climate: A Field Study
… has encouraged the use of underfloor air distribution systems (UFAD). This relatively new space conditioning system is believed to provide benefits of better energy performance, improved indoor air quality, workplace flexibility, higher levels of occupant comfort and personal control. …
-
CFD simulations to improve air distribution inside cold climate broiler houses involving heat exchangers
… the heating requirement, by preheating fresh air inlet with stale air outlet. While there have been many studies on the improvement of direct ventilation in both hot and cold climate, little attention has been given to heat exchangers in broiler houses. It is therefore unknown how best to …
-
Quantifying Air Distribution, Ventilation Effectiveness and Airborne Pollutant Transport in an Aircraft Cabin Mockup
… during flight inspired this research into cabin air quality, which is closely related to its airflow distribution, ventilation effectiveness and airborne pollutant transport. The experimental facility is a full-scale aircraft cabin mockup. A volumetric particle tracking velocimetry (VPTV) …
-
Design and Evaluation of Air Distribution Systems in Agricultural Tractor Cabs for Summer Environmental Control
… a tractor cab. The conditioning and control of air in an agricultural tractor cab is a relatively new field. Establishing criteria for acceptable comfort zones within a tractor cab is the first step in the-design of adequate environmental control for the operator. A second step is to evaluate a …
-
Energy comparison of under floor air distribution heating ventilation and air conditioning systems in office buildings
… to compare energy consumption with under floor air distribution systems for office buildings, specifically a call center application.;The building being modeled will have an HVAC system that utilizes an underfloor air distribution system (UFAD). This type of system allows air to be introduced …
-
A BIM-Based Approach for Optimizing HVAC Design and Air Distribution System Layouts in Panelized Houses
In a centralized air distribution system, the designed ductwork layout impacts the system performance and the construction time and cost. Engineers face various challenges, including spatial limitations, leading them to use assumption-based design methods to balance their design with construction …
-
Modeling and Control of Passive Chilled Beams with Underfloor Air Distribution of Ventilation in Office Buildings in Humid Climates
… beams with a ventilation system and underfloor air distribution (UFAD). For the analysis, a 606,900 ft2 commercial office building in ASHRAE climate zone 3A with passive chilled beams and a ventilation system with UFAD was selected as the case-study building. In the first step, measured data …
-
Performance and Optimization of an Underfloor Air Distribution System in an Educational Building in a Hot and Humid Climate
… strategies that involve the underfloor air systems combined with Energy Recovery Ventilation (ERV) especially in hot and humid climate. This thesis examines the performance and optimization of underfloor air distribution systems (UFAD) in hot and humid climates. This thesis also compares …
-
A study of the effect of air distribution on the combustion process in a simulated turbo-jet combustion chamber
A survey of the different components of the present day turbo jet engine shows a considerable volume of data available for the design of all except the combustion chamber. The very nature of the turbo jet places severe requirements on the combustion chamber. These requirements are essentially those …
Page 1 of 8