Company Air Handling Unit Online Management System /
Currently company air handling units are used for ventilation of buildings and they can only be controlled in local area network (LAN). This does not allow the company customers to control the microclimate of their home in a convenient way (e.g. when they are away from home). Therefore, there is a …
-
Demand Controlled Ventilation Energy Savings for Air Handling Units
… usage of a building. Coherent management of an air handling system’s energy is a key factor of reducing the energy costs and CO2 emissions that are associated with the demand for ventilating and conditioning the air in a building. The issue is that buildings are frequently over ventilated as a …
-
A digital simulation of a dual-duct air handling system
… a dynamic digital simulation of a dual-duct air handling system. The individual control loops and system components of the dual-duct system which was studied are explained in detail. The testing and data recording devices used in the investigation are described. An appropriate model for the …
-
Process monitoring and fault classification for an air handling unit
… methods to identify system faults in an air-handling unit (AHU). The effects of using a reduced amount of available information are investigated. The faults are simulated and are applied in an actual flow loop facility;The process model fault scheme as presented in Iserman (1987) was …
-
Optimal design and control in dual -duct air -handling units
Dual-duct systems provide good air circulation, require little maintenance, and have no condensation at the terminal boxes. However, dual-duct systems are believed to consume more energy than single-duct variable air volume systems. To address this issue, an extensive investigation was performed to …
-
Digital control for an existing variable-air-volume air handling system
… thesis presents the modifications to a variable-air-volume (VAV) system designed to improve the system efficiency. An improved control strategy is applied using direct digital control. The system operates in a medium-size office building (85,000 ft.<sup>2</sup> ) and is used only for cooling. The …
-
Field Evaluation and Anaysis of a Liquid Desiccant Air Handling System
A thermal liquid desiccant air handling machine was procured, installed, and field tested. The goal of the present investigation is to evaluate the field performance of the machine and characterize its operation for the temperature range of a solar thermal array. The system studied includes a …
-
Development of an integrated air handling system for large commercial buildings
… systems. As one solution to this problem, an all-air AHU system for large commercial building, named Integrated Office Air Handling Unit (OAHU) system, has been developed in this study. This dissertation covers: Description of the new system. A summary of conventional AHU systems for large …
-
Energy Optimization of Air Handling Unit Using CO₂ Data and Coil Performance
Air handling unit systems are the series of mechanical systems that regulate and circulate the air through the ducts inside the buildings. In a commercial setting, air handling units accounted for more than 50% of the total energy cost of the building in 2013. To make the system more energy …
-
Modeling and Analysis of an Air Handling Unit to Improve Energy Efficiency
The Air Handling Unit (AHU), which serves the entire basement of Engineering and Technology (ET) building on IUPUI campus, had constant set points of discharge air temperature and supply air static pressure. Two reset schedules were investigated to determine which was the best control strategy to …
-
Space Requirements for Technical System in Office Buildings - Air handling plant room model
This study illustrates how the air handling plant room geometry depends on the Specific Fan Power (kW/(m3/s)) and airflow rate (m3/s) by using a theoretical model. The total shaft area of an office building relate to the gross external area and ultimately examines the possibility to utilize the …
-
Development of an integrated laboratory air handling unit (LAHU) system for laboratory buildings
… development and implementation of an integrated air handling unit system for laboratory buildings, called the Laboratory Air Handling Unit (LAHU) system. This system minimizes thermal energy use and improves the office area indoor air quality (IAQ) in laboratory buildings. Theoretical optimal …
-
Evaluation of Performance of an Air Handling Unit Using Wireless Monitoring System and Modeling
Heating, ventilation, and air conditioning (HVAC) is the technology responsible to maintain temperature levels and air quality in buildings to certain standards. In a commercial setting, HVAC systems accounted for more than 50% of the total energy cost of the building in 2013 [13]. New control …
-
The use of fault detection and diagnostics to reduce air handling unit energy consumption
… is between 20% and 40%. Heating Ventilation and Air Conditioning (HVAC), and more specifically Air Handling Units (AHUs) energy consumption accounts on average for 40% of a typical medical device manufacturing or pharmaceutical facility’s energy consumption. Studies have indicated that 20 – 30% …
-
SELECTION CRITERIA FOR CENTRAL AND INDIVIDUAL AIR HANDLING UNITS FOR A TALL AIR-CONDITIONED BUILDING
… energy simulation program is used to determine air volume for a high rise building. The equal friction method in calculating friction losses is employed to size the ducts. ASHRAE Duct Fitting Database is used for calculating dynamic losses of fittings. Fans are selected from manufacturer's …
-
Fault Detection and Diagnostics in Single-Duct Multiple-Zone Variable Air Volume Air Handling Unit Systems
Variable air volume (VAV) air handling unit (AHU) systems are the most common heating, ventilation, and air conditioning (HVAC) configuration in North America's commercial buildings. They account for a large fraction of sensors and actuators and are prone to faults due to their control systems' …
-
Estimation And Forecasting Of Air Handling Condensate Recovery Using Multiple Regression Analysis And Time-Series Autoregressive Models
… parameters on the condensate production of four air handling units in campus research buildings in Birmingham, Alabama. Condensate production of four air handlers was recorded at one minute intervals to obtain the hourly condensate production. Hourly data of dry-bulb temperature, humidity, dew …