Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 111 for “"Air handling unit"”.

  1. Company Air Handling Unit Online Management System /

    Currently company air handling units are used for ventilation of buildings and they can only be controlled in local area network (LAN). This does not allow the company customers to control the microclimate of their home in a convenient way (e.g. when they are away from home). Therefore, there is a …

    vilnius Repository record for Company Air Handling Unit Online Management System / (opens in a new tab)

  2. Process monitoring and fault classification for an air handling unit

    … methods to identify system faults in an air-handling unit (AHU). The effects of using a reduced amount of available information are investigated. The faults are simulated and are applied in an actual flow loop facility;The process model fault scheme as presented in Iserman (1987) was …

    iastate Repository record for Process monitoring and fault classification for an air handling unit (opens in a new tab)

  3. Energy Optimization of Air Handling Unit Using CO₂ Data and Coil Performance

    Air handling unit systems are the series of mechanical systems that regulate and circulate the air through the ducts inside the buildings. In a commercial setting, air handling units accounted for more than 50% of the total energy cost of the building in 2013. To make the system more energy …

    iupui Repository record for Energy Optimization of Air Handling Unit Using CO₂ Data and Coil Performance (opens in a new tab)

  4. Modeling and Analysis of an Air Handling Unit to Improve Energy Efficiency

    The Air Handling Unit (AHU), which serves the entire basement of Engineering and Technology (ET) building on IUPUI campus, had constant set points of discharge air temperature and supply air static pressure. Two reset schedules were investigated to determine which was the best control strategy to …

    iupui Repository record for Modeling and Analysis of an Air Handling Unit to Improve Energy Efficiency (opens in a new tab)

  5. Development of an integrated laboratory air handling unit (LAHU) system for laboratory buildings

    … development and implementation of an integrated air handling unit system for laboratory buildings, called the Laboratory Air Handling Unit (LAHU) system. This system minimizes thermal energy use and improves the office area indoor air quality (IAQ) in laboratory buildings. Theoretical optimal …

    nebraska Repository record for Development of an integrated laboratory air handling unit (LAHU) system for laboratory buildings (opens in a new tab)

  6. Evaluation of Performance of an Air Handling Unit Using Wireless Monitoring System and Modeling

    Heating, ventilation, and air conditioning (HVAC) is the technology responsible to maintain temperature levels and air quality in buildings to certain standards. In a commercial setting, HVAC systems accounted for more than 50% of the total energy cost of the building in 2013 [13]. New control …

    iupui Repository record for Evaluation of Performance of an Air Handling Unit Using Wireless Monitoring System and Modeling (opens in a new tab)

  7. The use of fault detection and diagnostics to reduce air handling unit energy consumption

    … is between 20% and 40%. Heating Ventilation and Air Conditioning (HVAC), and more specifically Air Handling Units (AHUs) energy consumption accounts on average for 40% of a typical medical device manufacturing or pharmaceutical facility’s energy consumption. Studies have indicated that 20 – 30% …

    cork Repository record for The use of fault detection and diagnostics to reduce air handling unit energy consumption (opens in a new tab)

  8. Fault Detection and Diagnostics in Single-Duct Multiple-Zone Variable Air Volume Air Handling Unit Systems

    Variable air volume (VAV) air handling unit (AHU) systems are the most common heating, ventilation, and air conditioning (HVAC) configuration in North America's commercial buildings. They account for a large fraction of sensors and actuators and are prone to faults due to their control systems' …

    carleton Repository record for Fault Detection and Diagnostics in Single-Duct Multiple-Zone Variable Air Volume Air Handling Unit Systems (opens in a new tab)

  9. A plug and play framework for an HVAC air handling unit and temperature sensor auto recognition technique

    <p>A plug and play framework for an HVAC air handling unit control system is proposed in this study. This is the foundation and the first step towards the plug and play HVAC control system that will eventually lead to self-configuring of HVAC control systems for automatic building controls system …

    iastate Repository record for A plug and play framework for an HVAC air handling unit and temperature sensor auto recognition technique (opens in a new tab)

  10. DEVELOPMENT AND EVALUATION OF NOVEL AIR HANDLING UNIT CONTROL STRATEGIES FOR IMPROVED BUILDING DEMAND FLEXIBILITY AND THERMAL COMFORT

    … power demand, up to 80% in some regions in the United States. With many flexible loads, buildings have the potential to reduce power demand during peak times and provide demand flexibility. Building enables demand flexibility through measures such as shifting energy use to another time and …

    oklahoma-thes Repository record for DEVELOPMENT AND EVALUATION OF NOVEL AIR HANDLING UNIT CONTROL STRATEGIES FOR IMPROVED BUILDING DEMAND FLEXIBILITY AND THERMAL COMFORT (opens in a new tab)

  11. Simulation on centrifugal fans operating at close distance: An investigation of different air handling unit constructions to improve fan efficiency

    … Finding an high energy efficient ventilation unit solution is of big interest for Swegon, the company which initiated this thesis, as it copes with current EU regulations and directives for environmental issues, and at the same time lowers the operating costs. The goal with this study is to …

    chalmers Repository record for Simulation on centrifugal fans operating at close distance: An investigation of different air handling unit constructions to improve fan efficiency (opens in a new tab)

  12. Investigation of the Effect of Multiple Centrifugal Fans Close to Each Other in Operation- A Numerical Study to Improve Fan Efficiency in an Air Handling Unit

    … in applications for treatment and ventilation of air, given their excellent ability to induce pressure and drive this flow medium. In manufacturing of compact Air Handling Units (AHU) where lower areal footprints are a necessity, several centrifugal fans (in parallel) are often use for each flow …

    chalmers Repository record for Investigation of the Effect of Multiple Centrifugal Fans Close to Each Other in Operation- A Numerical Study to Improve Fan Efficiency in an Air Handling Unit (opens in a new tab)

  13. Calibration of a Building Energy Model Using Measured Data for a Research Center

    … study presents the calibration at the zone and air handling unit level. First a literature review is presented, followed by the evidence-based bottom-up methodology. Next, the case study building is described, along with the extraction and analysis of the monitored data. Then the building model …

    concordia Download PDF for Calibration of a Building Energy Model Using Measured Data for a Research Center (opens in a new tab)

  14. Pumparbete samt returtemperatur för tre alternativa lösningar vid koppling till luftvärmare

    … of electric energy. There are pumps and fans in air-handling units. The task of the air handling unit is to provide the desired thermal indoor climate according to the demand of the users of the building. Buildings need heating or cooling in order to achieve the thermal comfort level. To do this …

    chalmers Repository record for Pumparbete samt returtemperatur för tre alternativa lösningar vid koppling till luftvärmare (opens in a new tab)

  15. Advanced Thermodynamic Analyses of Energy Intensive Building Mechanical Systems

    … has not been extensive efforts in the areas of air distribution systems or cooling plants. Motivations for this new work include demonstrating the merits of exergetic analysis in association with retrocommissioning (RCX) an existing building air handling unit (AHU), as well as conducting an …

    rit Repository record for Advanced Thermodynamic Analyses of Energy Intensive Building Mechanical Systems (opens in a new tab)

  16. An Inverse Model-based Approach to Estimate Air Infiltration in Commercial Buildings using Occupant-generated CO2 and Humidity

    Monitoring air infiltration continuously is of great importance to detect building envelope degradation over time. However, environmental factors often make the accurate measurement of air infiltration challenging. Further, fan pressurization and tracer gas tests possess certain drawbacks limiting …

    carleton Repository record for An Inverse Model-based Approach to Estimate Air Infiltration in Commercial Buildings using Occupant-generated CO2 and Humidity (opens in a new tab)

Page 1 of 6