Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 90 for “"Air leakage"”

  1. Air leakage in underground mine ventilation

    Air leakage in underground mines is the most common cause of inefficient distribution of ventilating air. Depending upon various factors, more than half of the fresh air entering a mine short-circuits to the return airways before reaching the working faces. Consequently, large leakages create an …

    vt Repository record for Air leakage in underground mine ventilation (opens in a new tab)

  2. Air leakage of Insulated Concrete Form houses

    Air leakage has been shown to increase building energy use due to additional heating and cooling loads. Although many construction types have been examined for leakage, an exploration of a large number of Insulated Concrete Form (ICF) houses has not yet been completed. This thesis first collects 43 …

    mit Repository record for Air leakage of Insulated Concrete Form houses (opens in a new tab)

  3. An innovative airtightness test procedure for separating envelope air leakage from interior partition air leakage in multi-zone buildings

    A new airtightness test procedure has been developed for separating exterior envelope air leakage from interior partition leakage, when testing a single zone within a multi- zone building. Historically, envelope leakage from a single zone within a multi-zone building could only be measured if exact …

    concordia

  4. Experimental procedure to evaluate air leakage through different building materials

    This work deals with the evaluation of air flow rate through different building materials used in the construction of building envelope. Experimental measurements of the air flow through and static pressure difference across building walls were carried out. For this purpose a new test configuration …

    concordia

  5. EXPERIMENTAL INVESTIGATION OF HEAT LEAKAGE AND AIR LEAKAGE IN DOMESTIC REFRIGERATORS

    … gasket which determines the heat transfer and air infiltration rate. In this research project, engineering methods are developed to evaluate the heat leakage due to the gasket and air infiltration in domestic refrigerators. In the first study, experimental and numerical approaches are applied …

    clemson Repository record for EXPERIMENTAL INVESTIGATION OF HEAT LEAKAGE AND AIR LEAKAGE IN DOMESTIC REFRIGERATORS (opens in a new tab)

  6. Sustaining compressed air DSM project savings using an air leakage management system

    … to alleviate this problem. Several compressed-air DSM projects were implemented to help reduce the strain on the electrical network. Compressed air is an integral part of production in deep-level mining, and is extensively utilised. Problems are encountered with the effective management and …

    nwu-za Repository record for Sustaining compressed air DSM project savings using an air leakage management system (opens in a new tab)

  7. A data-driven approach to detect air leakage in a pneumatic system

    … to identify an early stage of a pneumatic leakage in a production process, before the leakage is so severe that it would impact the process adversely and cause machine breakdown. Through two experiments and extraction of historical data coming from sensors, a supervised machine learning …

    chalmers Repository record for A data-driven approach to detect air leakage in a pneumatic system (opens in a new tab)

  8. Local air leakage measurement and Cfd analysis of deformed ducts in residential HVAC ducts

    … is developed to identify and quantify the local air leakage rates in residential HVAC ducts. The technique is based on duct pressurization test (ANSI/ASHRAE standard 152/2004) along with a zone bag to create artificial restrictions. The experiments were conducted at the Air Duct Leakage …

    unlv Repository record for Local air leakage measurement and Cfd analysis of deformed ducts in residential HVAC ducts (opens in a new tab)

  9. Advancing building air leakage measurement and modelling: new measurement methods and experimental analysis of crack flow behavior

    The ability to measure air leakage in multi-zone buildings, both through the exterior envelope and between different zones inside the building (interior leakage), is important since they have a direct impact on energy consumption, indoor air quality and moisture accumulation. While blower door …

    bu Repository record for Advancing building air leakage measurement and modelling: new measurement methods and experimental analysis of crack flow behavior (opens in a new tab)

  10. Assessing the Impact of Air Leakage on the Hygrothermal Performance of Wood-Frame Walls Under Historical and Future Climates

    Air leakage is a crucial factor when assessing the hygrothermal performance of wood-frame walls since it can lead to moisture accumulation during the cold season. The seriousness of this prob-lem may change in a warmer climate in the future and hygrothermal simulations are widely used as a tool to …

    concordia

  11. Impact of added insulation on the hygrothermal performance of leaky exterior wall assemblies

    … to leak exterior wall assemblies and to monitor air leakage paths within them. The procedure involves the construction of a full-scale test hut exposed consecutively to climatic conditions representing winter and late spring, inside the environmental chamber. Two re-insulation strategies are …

    concordia

  12. Air Tightness in Car Coupe

    This thesis presents developing work about air leakage detecting method for Volvo car body. The purpose of this project is to find out an efficient and effective way of detecting the air leakage point in car body that meets all the requirements given from Volvo Car Corporation. The whole project …

    chalmers Repository record for Air Tightness in Car Coupe (opens in a new tab)

  13. HVAC Economizer Redesign

    … economizer is a HVAC (Heating, Ventilation, and Air Conditioning) appliance designed to regulate the intake and outtake of ambient air of HVAC devices, such as building air conditioners. This design project was conducted in collaboration with MicroMetl Corporation, a local sheet metal company …

    unr Repository record for HVAC Economizer Redesign (opens in a new tab)

  14. Assessing the airtightness performance of container-like buildings in relation to its effect on energy efficiency

    This study analyzes the effect of airtightness on the energy efficiency of single and adjacent containerized buildings, before and after refurbishment. It further gives an overview of air leakage problems found in the sample of prefabricated buildings manufactured and located in Turkey. The air …

    metu Repository record for Assessing the airtightness performance of container-like buildings in relation to its effect on energy efficiency (opens in a new tab)

  15. The Hygrothermal Performance of Exterior Insulated Wall Systems

    … moisture durability: 1) increased potential for air leakage condensation at the sheathing and 2) decreased ability of the wall to dry after a wetting event. A natural exposure experimental study was performed at the University of Waterloo’s BEGHUT test facility to evaluate the hygrothermal …

    waterloo Repository record for The Hygrothermal Performance of Exterior Insulated Wall Systems (opens in a new tab)

  16. Essays on Environmental Economics

    … usage. Chapter 2 assesses realized energy and air leakage changes in homes constructed before and after new building energy code adoptions in three Canadian provinces: Ontario, New Brunswick, and Alberta. We find no electricity or air leakage reductions attributable to more stringent code …

    carleton Repository record for Essays on Environmental Economics (opens in a new tab)

Page 1 of 5