Results 1 to 20 of 108 for “"Air ventilation"”
-
Post-processing technique enhancement for computational fluid dynamics based air ventilation assessment
<p>In 2006, the Hong Kong government adopted the Air Ventilation Assessment (AVA) for major development projects. It aims to provide a better guideline for policymakers and urban planners to enhance the urban environment and the air quality. AVA has a detailed standard for its required studies, but …
-
Application of chilled ceiling cooling with floor-level air ventilation in office spaces
An innovative air-conditioning concept of a chilled ceiling combined with a floor-level ventilation system was developed in Europe and North America. Full-scale testing results in office spaces equipped with such systems showed that occupants can readily achieve thermal comfort. Currently, chilled …
-
THE FORMER SUPREME COURT BUILDING AND ITS SOLO-AIR VENTILATION SYSTEM: A CASE OF CONSTRAINT-BRED INGENUITY IN DESIGN
… of the Supreme Court is the way in which the ventilation needs of the sealed court rooms, attendant rooms and the library were tackled during a time when mechanical ventilation was still a novelty. In their quest to construct a non-indigenous building in hot tropical Singapore, as well as work …
-
Development of a scaled down laboratory test bed system for use in the optimisation of centrifugal fan driven air ventilation systems.
… bed for use in the optimisation of fan driven air ventilation systems found at the various Anglo Coal South African mines. The present system involved in the movement of air underground comprises a fixed speed centrifugal fan driven damper controlled system. National Power Contractors (NPC) …
-
PASSIVE SOLAR ENERGY DESIGN OF BUILDING IN SINGAPORE : SOLAR INDUCED VENTILATION CUM WATER HEATING SYSTEM
… in Singapore emphasizing on solar induced ventilation cum water heating system. The focus of the study is to develop a hybrid system of solar induced air ventilation cum water heating in a low rise residential house. This system incorporates a cheap collector as a solar roof on the building …
-
Whole-house mechanical ventilation in a mixed-humid climate
… tighter home construction, the need for outdoor air ventilation to improve indoor air quality increases. Major improvements in building envelopes and duct systems have led to decreases in heating and cooling loads causing fewer HVAC system run-time hours, and increasing the probability for air …
-
NATURAL AND VENTILATED CAVITATING FLOW OVER HIGH-SPEED UNDERWATER VEHICLE
… number is low. At moderate cavitation number, air ventilation is needed. The ventilated cavitating flow over an axisymmetric projectile is investigated at a wide range of natural cavitation numbers, which is much more stable than the natural cloud cavitating flow. The results show that air …
-
Utilização de Quimiometria na avaliação da influência de diferentes níveis de circulação de ar na determinação de umidade por secagem em estufa de ar forçado
… in foods is drying it in an oven with forced air circulation. Equipment available on the market nowadays have settings which allows the control of air ventilation percentage, and air exchange with the environment. The official methods available are not updated at as quickly new equipment is …
-
Baseino patalpų vėdinimo įrangos eksploatacinių parametrų tyrimas /
… of solutions already existing in the market air venting system with the controller was created. It was designed for indoor swimming pool environment and does not depend on indoor or outdoor weather conditions. Air ventilation control systems and their operation modes (including automatical …
-
Operating Theatres: Study of Unidirectional Flow Ventilation- Conditions for microbiological air cleanliness during advanced surgeries
Design of a heating, ventilating and air conditioning (HVAC) system for an operating room is aimed at preventing the risk of infections during surgical operations while maintaining an adequate comfort condition for the patient and the surgical staff. One of the key elements to ensure the OT …
-
Analyzing Indoor and Outdoor Heat Index Measurements in Kitchens
… as well as kitchen production levels and forced air ventilation. The results showed that higher production kitchens had a significantly greater increase in Heat Index compared to low production and high production kitchens with forced air ventilation. Due to the small sample size of this study, …
-
Pedestrian-level wind environment around buildings--with special reference to the effects of building dimensions, building separation and podium structure
… were modeled, including single building, a pair of buildings, a row of four buildings and podium structures, to investigate the effects of building dimension, building separation and podium on the surrounded pedestrian-level wind environments.</p><p>In the wind tunnel simulation, Irwin Sensor …
-
Self-heating and spontaneous combustion of wood pellets during storage
… wood pellet silo. The influences of cooling airflow rate, wall insulation, and dimension of the storage container, ambient temperature and wind condition were studied. The results show that air ventilation inside of the silo is a very effective approach for reducing self-heating and …
-
Airborne infection in healthcare environments: Implications to hospital corridor design
… studies have linked nosocomial transmission airborne diseases to airflow in healthcare settings. Quasi-experimental methods are developed to observe the aerodynamic transport behavior of synthetic respiratory particles in corridors of a hospital. Computational models, validated by …
-
Evaluation of seasonal ventilation changes and their effect on ambient dust, endotoxin and bioaerosol concentrations in a dairy parlor
This pilot study measured the impact of seasonal ventilation changes on concentrations of organic dust, endotoxin and bacteria in one modern dairy milking parlor. Pyrosequencing, a new non-target specific molecular methodology was used to characterize airborne bioaerosols. Area samples for …
-
Demand Controlled Ventilation Energy Savings for Air Handling Units
Heat, cooling, and ventilation units are major energy consumers for commercial buildings, they can consume as much as 50% of the total annual power usage of a building. Coherent management of an air handling system’s energy is a key factor of reducing the energy costs and CO2 emissions that are …
-
Physiological and Perceived Psychological Responses of Collegiate Football Athletes to Ventilated Shoulder Pads During a Scrimmage
… of this study was to assess the effect of cold air ventilated shoulder pads on core temperature and perceived exertion in football athletes during a scrimmage. METHODS: Eight football athletes were randomly divided into two groups, one receiving cold air ventilation (v) and the other receiving …
-
Decay Rates of Aerosolized Particles in Dental Practices
… equipment, such as a high-speed handpiece and an air/water syringe, are used to create aerosolized particles. Various practical environment management factors are addressed, such as having the operatory door open or closed, using an extraoral suction unit or a HEPA filtered air purifier, and …
-
Life-cycle costing for cleanroom construction
… area, corresponding cleanliness class, make-up air volume, exhaust air volume, type of air ventilation and type of air return. The internal relationship between these parameters and cleanroom life cycle cost are presented.The research findings contribute to cleanroom investment budgeting and …
-
Sick building syndrome : the phenomenon and its air-handling etiology
This thesis studied empirically the air-handling etiology of the nonspecific symptoms of the eyes, respiratory tract, skin, and central nervous system in office workers, often termed the sick building syndrome. The results of a four-period crossover trial in 75 office workers suggest that 70% air …
Page 1 of 6