Showing 1 to 20 of 150 for “"Air void"”.

  1. Entrained Air-Void System For Durable Highway Concrete

    … heating elements. These units are easily repaired by conventionally trained heating and air conditioning technicians and economically modified using readily available controls. Consequently, proposed factors and modifications to the test method are based on this piece of equipment. Sufficient …

    umkc Repository record for Entrained Air-Void System For Durable Highway Concrete (opens in a new tab)

  2. Developing An Alternative Hardened Concrete Air Void Characterization Method

    … characterization method for the hardened air void system in concrete. This study uses ASTM C457, “Standard Test Method for Microscopical Determination of Parameters of the Air-Void System in Hardened Concrete” as a baseline characterization method and attempts to thoroughly reduce the long …

    texas-state Repository record for Developing An Alternative Hardened Concrete Air Void Characterization Method (opens in a new tab)

  3. Air void characteristics of air-entrained self-consolidating concrete

    … slump flow, hauling time and remediation on the air void characteristics of air-entrained self-consolidating concrete (SCC). The first phase of the investigation focused on the effects of four different admixture manufacturers and three distinct slump flows on the fresh flow properties and air …

    unlv Repository record for Air void characteristics of air-entrained self-consolidating concrete (opens in a new tab) Download PDF for Air void characteristics of air-entrained self-consolidating concrete (opens in a new tab)

  4. Pavement Air Void Property Determination and Incorporation of Pavement Air Void Properties in Pavement Oxidation Modeling with an Emphasis on X-Ray CT Image Analysis

    … of oxygen into the asphalt from pavement air voids. To improve upon previous modeling efforts, this work investigated measurement of pavement air void properties and incorporation of air void properties in pavement oxidation modeling. A method for analyzing x-ray computed tomography (CT) …

    tamu Repository record for Pavement Air Void Property Determination and Incorporation of Pavement Air Void Properties in Pavement Oxidation Modeling with an Emphasis on X-Ray CT Image Analysis (opens in a new tab)

  5. X-ray Computed Tomography Assessment of Air Void Distribution in Concrete

    Air void size and spatial distribution have long been regarded as critical parameters in the frost resistance of concrete. In cement-based materials, entrained air void systems play an important role in performance as related to durability, permeability, and heat transfer. Many efforts have been …

    toronto-retro Repository record for X-ray Computed Tomography Assessment of Air Void Distribution in Concrete (opens in a new tab)

  6. Air entrainment and variation of air void system in fresh concrete

    <p>An adequate air void system in concrete is critical to its freeze-thaw (F-T) durability. With an effective air void system, concrete can survive longer in a wet climate with F-T cycles. Over the years, researchers have focused on fresh air content and the hardened air void system, but little …

    iastate Repository record for Air entrainment and variation of air void system in fresh concrete (opens in a new tab)

  7. Air void clustering in retempering concrete and its contribution to compressive strength

    <p>Air void clustering is a phenomenon in concrete in which air bubbles accumulate around the coarse aggregate. It is considered as a major cause of reduction of concrete strength.</p> <p>This thesis focuses on the effect of different variables on air void clustering and its contribution to the …

    iastate Repository record for Air void clustering in retempering concrete and its contribution to compressive strength (opens in a new tab)

  8. Advances in measuring parameters of the air-void system in hardened concrete

    … the freezing and thawing resistance of concrete, air bubbles are entrained and distributed evenly and closely. Evaluation of the parameters of the air-void system in hardened concrete is detailed in ASTM C457 “Standard Test Method for Microscopical Determination of Parameters of the Air-Void …

    uiuc Repository record for Advances in measuring parameters of the air-void system in hardened concrete (opens in a new tab)

  9. Freeze-Thaw Durability and Digital Hardened Air Void Analysis of Self Consolidating Concrete

    … traditional moist curing were observed. Hardened air void analysis was digitally performed using a flat-bed scanner and two programs. The first program used Adobe Photoshop and was developed by Michigan Tech University, and the second program was developed in the WVU laboratory and uses MATLAB. …

    wvu Repository record for Freeze-Thaw Durability and Digital Hardened Air Void Analysis of Self Consolidating Concrete (opens in a new tab)

  10. Evaluation of the field application of the Air Void Analyzer in quality control.

    … concrete mix were evaluated to establish the Air Void Analyzer (AVA) as a means of real-time, ???In-the-Field??, Quality Control testing method. In this study, both the Air Void Analyzer and conventional test methods were used to examine each concrete mix. Each mix was evaluated three times to …

    louisville Repository record for Evaluation of the field application of the Air Void Analyzer in quality control. (opens in a new tab)

  11. Analysis of air-void system in hardened concrete from a three-dimensional perspective

    … can be greatly enhanced by entrainment of small air bubbles in the cement paste. When the volume and distribution of the entrained air is properly controlled, the microstructure is protected from pressure exerted by freezing water. ASTM C457 “Standard Test Method for Microscopical Determination …

    uiuc Repository record for Analysis of air-void system in hardened concrete from a three-dimensional perspective (opens in a new tab)

  12. Air void characterization in fresh cement paste through ultrasonic attenuation using an immersion procedure

    … based materials is through the entrainment of air voids using air entraining chemical admixtures (AEA's). However, the common field methods for measuring air content in fresh concrete cannot distinguish between entrained and entrapped air voids, and the actual air content in the hardened …

    gatech Repository record for Air void characterization in fresh cement paste through ultrasonic attenuation using an immersion procedure (opens in a new tab)

  13. Influence of fundamental material properties and air void structure on moisture damage of asphalt mixes

    … capillary rise of water. The amount and size of air voids filled with water were used in the capillary rise equation to estimate the distribution of the contact angles between the water and the mastic. The results were able to show the influence of air void size on capillary rise and contact …

    tamu Repository record for Influence of fundamental material properties and air void structure on moisture damage of asphalt mixes (opens in a new tab)

  14. Determining the Air Void Parameters of Concrete Using Digital Image Analysis of Polarized Light Micrographs

    … test has long been a standard used to obtain the air void parameters of concrete materials. These air void parameters provide valuable information that has been linked to the performance of concrete under conditions such as freezing and thawing cycles. The standard test procedure involves linearly …

    vt Repository record for Determining the Air Void Parameters of Concrete Using Digital Image Analysis of Polarized Light Micrographs (opens in a new tab)

  15. Three-dimensional Segmentation of Air-void System in Hardened Concrete using Photometric Stereo and Artificial Intelligence Methods

    A well-distributed air-void system inside a hardened concrete can help protect the concrete structure from being damaged by freeze-thaw cycles. The concrete air-void petrographic test, which is specified in ASTM C457, is the standard test procedure for characterizing the air-void system and …

    texas-state Repository record for Three-dimensional Segmentation of Air-void System in Hardened Concrete using Photometric Stereo and Artificial Intelligence Methods (opens in a new tab)

  16. Probabilistic analysis of air void structure and its relationship to permeability and moisture damage of hot mix asphalt

    … on relating permeability to the average percent air voids in the mix. Such relationships cannot predict permeability accurately due to the different distributions of air void structures at a given average percent of air voids. Air void distribution is a function of many factors such as mix …

    tamu Repository record for Probabilistic analysis of air void structure and its relationship to permeability and moisture damage of hot mix asphalt (opens in a new tab)

  17. Development of image analysis techniques to assist evaluation of both air void structure and aggregate shape factors in concrete

    … and durability of concrete is brought about by voids left within the concrete once it has hardened. These voids can arise from a number of sources both intentional, in the case of air-entrained voids introduced by admixtures batched to provide a structure that can withstand frost attack and …

    wlv Repository record for Development of image analysis techniques to assist evaluation of both air void structure and aggregate shape factors in concrete (opens in a new tab) Download file for Development of image analysis techniques to assist evaluation of both air void structure and aggregate shape factors in concrete (opens in a new tab)

  18. An Investigation of the Effect of Performance Engineered Mixture (PEM) Design on Durability and Air Void Matrix of Concrete Pavements

    … curve for aggregate grading, and the Super Air Meter (SAM) test, providing information regarding the air void matrix while the concrete is fresh. To achieve these properties with less cement will lead to decreased material costs, decreased concrete carbon footprint, and decreased durability …

    arkansas Repository record for An Investigation of the Effect of Performance Engineered Mixture (PEM) Design on Durability and Air Void Matrix of Concrete Pavements (opens in a new tab)

  19. Effect of Ground Glass Composition on the Compressive Strength, Replacement Level, Hardened Air-Void System, and Microstructure of Portland Cement Mortars

    … was measured through six months. The hardened air void structure was analyzed past six months. Most glasses met 75% Strength Activity Index at 7 and 28 days when a 20% replacement level was used. An increased replacement level of 30% resulted in lower compressive strength for all but E-glass. …

    umn Repository record for Effect of Ground Glass Composition on the Compressive Strength, Replacement Level, Hardened Air-Void System, and Microstructure of Portland Cement Mortars (opens in a new tab)