Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 39 for “"Air void system"”
-
Entrained Air-Void System For Durable Highway Concrete
… construction of a refrigerant-based cooling system and resistive heating elements. These units are easily repaired by conventionally trained heating and air conditioning technicians and economically modified using readily available controls. Consequently, proposed factors and modifications to …
-
Air entrainment and variation of air void system in fresh concrete
<p>An adequate air void system in concrete is critical to its freeze-thaw (F-T) durability. With an effective air void system, concrete can survive longer in a wet climate with F-T cycles. Over the years, researchers have focused on fresh air content and the hardened air void system, but little …
-
Advances in measuring parameters of the air-void system in hardened concrete
… the freezing and thawing resistance of concrete, air bubbles are entrained and distributed evenly and closely. Evaluation of the parameters of the air-void system in hardened concrete is detailed in ASTM C457 “Standard Test Method for Microscopical Determination of Parameters of the Air-Void …
-
Analysis of air-void system in hardened concrete from a three-dimensional perspective
… can be greatly enhanced by entrainment of small air bubbles in the cement paste. When the volume and distribution of the entrained air is properly controlled, the microstructure is protected from pressure exerted by freezing water. ASTM C457 “Standard Test Method for Microscopical Determination …
-
Three-dimensional Segmentation of Air-void System in Hardened Concrete using Photometric Stereo and Artificial Intelligence Methods
A well-distributed air-void system inside a hardened concrete can help protect the concrete structure from being damaged by freeze-thaw cycles. The concrete air-void petrographic test, which is specified in ASTM C457, is the standard test procedure for characterizing the air-void system and …
-
Effect of Ground Glass Composition on the Compressive Strength, Replacement Level, Hardened Air-Void System, and Microstructure of Portland Cement Mortars
… was measured through six months. The hardened air void structure was analyzed past six months. Most glasses met 75% Strength Activity Index at 7 and 28 days when a 20% replacement level was used. An increased replacement level of 30% resulted in lower compressive strength for all but E-glass. …
-
Investigation of Concrete Pumping Effects on Air-Entrained Concrete
This work investigates how pumping affects the air void system in the fresh and hardened concrete. This work pumped a similar mixture design with varying air contents in laboratory and field environments to investigate the air void system before and after pumping. The Super Air Meter (AASHTO TP118) …
-
Stability and Quality of Air Void Systems in Concretes with Superplasticizers
… polycarboxylate superplasticizers with different air entraining agents in modern concrete. A novel testing method was invented for analyze the changes over time in the mixtures as well as the stability of the air void system produced. Data collected included the slump, the unit weight, the fresh …
-
Studying air properties in hardened Portland cement concrete with Linear Traverse Method.
Air void structure in hardened concrete is critical to its durability. This project mainly focuses on investigating the air void system in hardened concrete with the microscopic analysis Linear Traverse Method specified by ASTM Specification C457-08 (Standard Test Method for Microscopical …
-
Evaluation of concrete mixing and its effects on portland cement concrete (PCC) properties
… studied. Four composition tests (unit weight, air content, coarse aggregate content, and water content of sieved mortar) and two performance tests (slump and compressive strength) are employed. The average, range, and coefficient of variation (CV) of these measurements from each given batch are …
-
Freeze-thaw performance of prestressed concrete railroad ties
Air voids are purposefully entrained in concrete to provide freeze-thaw durability of prestressed concrete railroad ties. Durability assurance requires consistent provision of an air void system comprised of small, well-distributed bubbles in sufficient quantity for durability and a quality control …
-
Developing An Alternative Hardened Concrete Air Void Characterization Method
… characterization method for the hardened air void system in concrete. This study uses ASTM C457, “Standard Test Method for Microscopical Determination of Parameters of the Air-Void System in Hardened Concrete” as a baseline characterization method and attempts to thoroughly reduce the long …
-
Minimizing the negative effect of pumping on SCC freeze-thaw durability
… but it also has the potential of altering the air void system parameters, which are key to guarantee proper durability under cold weather conditions. This research has as main goal to expand the current knowledge related to the behavior of the air-void system of highly flowable concrete (HWC), …
-
Pumping of concrete mixtures: rheology, lubrication layer properties and pumping pressure assessment
… pressure on concrete fresh properties and the air void system under controlled conditions, and (4) to evaluate the effect of pumping on concrete fresh properties and the air void system in the field conditions. In the first phase of this research program, a correction procedure was developed …
-
Determining the Air-void Distribution of Fresh Concrete with the Sequential Pressure Method
… the SAM number, to determine the quality of the air-void system. This research also looks at the reliability, repeatability, and variability of the SAM testing procedure. This study looked into 9 different mixture types with varying w/cm ratios and admixtures. The difference between identical air …
-
Quantifying air-void distribution and associated uncertainty in fresh and hardened concrete
… Powers recommended entraining a well-distributed air-void system (comprised of equally spaced, small air voids) through the cementitious paste to minimize frost damage in PCCP. There are several methods to measure total air content in fresh concrete, such as ASTM C231 (volumetric air content using …
-
Super Absorbent Polymers (SAPs) as physical air entrainment in cement mortars
… for using SAPs as a mechanism for physical air entrainment. Mixtures were produced using various quantities of either dry or pre-saturated SAP to replace conventional air entrainment agents (AEAs) along with a conventionally air-entrained control. One additional mixture used lightweight fine …
-
Quantifying the efficiency and quality of air void distributions in concrete
… establishes new ways to measure and examine the air bubble distribution within concrete. This is important to provide freeze thaw durability and resistance to oxychloride formation. These bubbles decrease the fluid pressure on freezing and crystal formation. The quality of the air void …
-
Air void characteristics of air-entrained self-consolidating concrete
… slump flow, hauling time and remediation on the air void characteristics of air-entrained self-consolidating concrete (SCC). The first phase of the investigation focused on the effects of four different admixture manufacturers and three distinct slump flows on the fresh flow properties and air …
-
Evaluation of the field application of the Air Void Analyzer in quality control.
… concrete mix were evaluated to establish the Air Void Analyzer (AVA) as a means of real-time, ???In-the-Field??, Quality Control testing method. In this study, both the Air Void Analyzer and conventional test methods were used to examine each concrete mix. Each mix was evaluated three times to …
Page 1 of 2