Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 67 for “"Air--Pollution--Measurement"”.

  1. Characterization and impact of ambient air pollution measurement error in time-series epidemiologic studies

    Time-series studies of ambient air pollution and acute health outcomes utilize measurements from fixed outdoor monitoring sites to assess changes in pollution concentration relative to time-variable health outcome measures. These studies rely on measured concentrations as a surrogate for population …

    gatech Repository record for Characterization and impact of ambient air pollution measurement error in time-series epidemiologic studies (opens in a new tab)

  2. Personalizing air pollution exposure estimation using wireless sensor network and machine learning approaches

    Metropolitan air pollution is a growing concern in both developing and developed countries because of its adverse impact on human health. Most countries have monitoring systems that estimate pollution at the regional level; however, little has been done by way of understanding exposure at the …

    unsw Repository record for Personalizing air pollution exposure estimation using wireless sensor network and machine learning approaches (opens in a new tab)

  3. Preconcentration and direct flame ionization method for measurement of non-methane organic compounds in ambient air and statistical analysis of experimental data

    … non-methane organic compounds (NMOC) in ambient air has been developed. Samples are collected in SUMMA polished stainless steel canisters using a sampling system with a critical orifice as flowrate controller. Analysis of NMOC in the atmosphere via a canister is carried out by cryogenic …

    njit Repository record for Preconcentration and direct flame ionization method for measurement of non-methane organic compounds in ambient air and statistical analysis of experimental data (opens in a new tab)

  4. Simplified real-time PAH measurement techniques

    … emissions has been hampered because existing PAH measurement techniques are slow, complex, and expensive. This study investigates two simple, inexpensive, real-time PAH measurement techniques which might be suitable for testing stoves. The first uses a device, called the "moving tape sampler" …

    vt Repository record for Simplified real-time PAH measurement techniques (opens in a new tab)

  5. Separation and characterization of biologically significant chemical classes in airborne particulate organic matter : measurement of selected chemical classes in freshly collected air samples

    <p>Since hazardous materials present in airborne pollutants can affect human health and environmental quality and most of the specific compounds remain uncharacterized, a study was conducted to characterize airborne particulate extractable organic matter (EOM) with respect to chemical composition. …

    njit Repository record for Separation and characterization of biologically significant chemical classes in airborne particulate organic matter : measurement of selected chemical classes in freshly collected air samples (opens in a new tab)

  6. Adsorption capabilities of adsorbents for selected toxic air pollutants

    … capacities of seven toxic, volatile organic air pollutants of either proven or suspected carcinogenic potential were tested on various adsorbents. Tests were run at flow velocities similar to those set in field sampling. This allows for extrapolation of test results to actual ambient air …

    njit Repository record for Adsorption capabilities of adsorbents for selected toxic air pollutants (opens in a new tab)

  7. Inhalation exposure pathways for polybrominated diphenyl ethers : a source to human receptor model for semivolatile organic compounds

    … fan. The concentration of PBDEs in the room air increases 40 - 80% for every 5°C increase inside the computer case, depending on the PBDE congener. Such enhanced emissions are a concern since recent studies have shown adverse health effects of PBDEs on human health. The major contributions of …

    texas Repository record for Inhalation exposure pathways for polybrominated diphenyl ethers : a source to human receptor model for semivolatile organic compounds (opens in a new tab)

  8. Determination of S(IV) at low parts per billion levels with anthranilic acid

    Measurement of sulfur(IV) in formaldehyde stabilized samples in the 1-50 ppb range is carried out using anthranilic acid as a fluorescent amine substrate. Results are presented for optimization of pH, reagent concentration and conditions for obtaining the best limits of detection, and data for real …

    ttu Repository record for Determination of S(IV) at low parts per billion levels with anthranilic acid (opens in a new tab)

  9. Extension and evaluation of screening technique for particulates

    The rapid screening procedure technique for the analysis of six hazardous metals in oxide form: beryllium, cadmium, copper, lead, mercury and zinc developed by Bethea and Lin has been extended to include seven ferrous and non-ferrous cations in their oxide forms. It is suitable for field use in the …

    ttu Repository record for Extension and evaluation of screening technique for particulates (opens in a new tab)

  10. An improved method of gas chromatographic determination of trace organic vapors in ambient air collected in canisters

    … of volatile organic compounds in ambient air has been developed. Samples are collected in evacuated SUMMA polished stainless steel canisters using a sampling flow apparatus with a critical orifice as flowrate controller. Analysis of VOCs in the collected air is carried out by cryogenically …

    njit Repository record for An improved method of gas chromatographic determination of trace organic vapors in ambient air collected in canisters (opens in a new tab)

  11. The Design and Construction of a Flashlamp-Pumped Frequency-Doubled Dye Laser Applicable to Long Path Monitoring of Air Pollutants

    … a laser light source which could be used in an air pollution monitor to measure the average concentration of sulfur dioxide gas over long paths (>1 km). Many of the problems encountered in designing a long-path pollutant monitor such as instrument cost and reliability, the selection of an …

    portland-state Repository record for The Design and Construction of a Flashlamp-Pumped Frequency-Doubled Dye Laser Applicable to Long Path Monitoring of Air Pollutants (opens in a new tab)

  12. Site Selection for Air Pollution Monitoring in the Vicinity of Point Sources

    Ever since air pollution became a national concern in the 1950's, more and more emphasis has been placed on collection of representative air samples for many purposed, to include (1) evaluation of the degree to which national ambient air quality standards are being met and (2) to monitor maximum …

    ucf Repository record for Site Selection for Air Pollution Monitoring in the Vicinity of Point Sources (opens in a new tab)

  13. Performance Comparison of Low-Cost Sensors Across Six Cities of Continental United States

    In the field of air quality measurement, low-cost sensors have been extensively used for capturing high-resolution spatial and temporal pollutant concentrations. However, data accuracy and the impact of environmental conditions particularly temperature and relative humidity, remain a significant …

    ucf Repository record for Performance Comparison of Low-Cost Sensors Across Six Cities of Continental United States (opens in a new tab)

  14. The measurement of depolarized radiation for monitoring the mass concentration of particulates

    … is indicated by performing the depolarization measurements simultaneously at two different optical paths. The depolarization ratio was found to be independent of size variations in the 0.5μ-8.0μ range at a refractive index ratio of 1.6 and independent of size variations in the 1.0μ-8.0μ …

    njit Repository record for The measurement of depolarized radiation for monitoring the mass concentration of particulates (opens in a new tab)

  15. Analysis of C2 and C3 hydrocarbons in ambient air. Section I ; Identification and quantification of volatile organics emitted from a landfill. Section II

    … Propylene and Propane levels in the ambient air. Chlorinated compounds within the operation retention time, Methyl chloride, Methylene chloride and Vinyl chloride, were monitored also.</p><p>Four sampling sites are located at Carteret, Elizabeth, Newark and Montville in New Jersey. Samples …

    njit Repository record for Analysis of C2 and C3 hydrocarbons in ambient air. Section I ; Identification and quantification of volatile organics emitted from a landfill. Section II (opens in a new tab)

Page 1 of 4