Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 15 of 15 for “"Air-void analysis"”
-
Freeze-Thaw Durability and Digital Hardened Air Void Analysis of Self Consolidating Concrete
… traditional moist curing were observed. Hardened air void analysis was digitally performed using a flat-bed scanner and two programs. The first program used Adobe Photoshop and was developed by Michigan Tech University, and the second program was developed in the WVU laboratory and uses MATLAB. …
-
Implementation of the Sequential Air Method in Laboratory and Field Studies
This work validates the Sequential Air Method (SAM) Number by analyzing data from laboratory, industry fieldwork, and a series of concrete mixtures with different admixture combinations. Comparisons are made to the total air content and hardened air-void analysis (ASTM C457) for the 458 concrete …
-
Durability analysis of self consolidating concrete used in the Stalnaker Run Bridge
… SCC beam's low freeze-thaw durability using the air-void analysis. Results from the coarse aggregate distribution analysis of the saw-cut cross sections and the core specimens of the SCC test beam show that the SCC beam exhibited significant segregation behavior. An air void analysis of the core …
-
Quantifying the efficiency and quality of air void distributions in concrete
… establishes new ways to measure and examine the air bubble distribution within concrete. This is important to provide freeze thaw durability and resistance to oxychloride formation. These bubbles decrease the fluid pressure on freezing and crystal formation. The quality of the air void …
-
Determining the Air-void Distribution of Fresh Concrete with the Sequential Pressure Method
… the SAM number, to determine the quality of the air-void system. This research also looks at the reliability, repeatability, and variability of the SAM testing procedure. This study looked into 9 different mixture types with varying w/cm ratios and admixtures. The difference between identical air …
-
The effects of liquid nitrogen on concrete hydration, microstructure, and properties
… chloride permeability, and hardened and fresh air void analysis. Hydration and microstructural development were monitored by isothermal calorimetry, semi-adiabatic calorimetry, x-ray diffractometry, inductively coupled plasma, and environmental scanning electron microscopy. Additional testing …
-
The durability of concrete using concrete plant wash water
… effect of the wash water on the effectiveness of air entraining agents (AEA) is being determined using air void analysis of specimens with different AEA contents. On the basis of the results obtained from the comparative study using wash water versus tap water, it appears that wash water can be …
-
Developing An Alternative Hardened Concrete Air Void Characterization Method
This study presents the development and analysis of an alternative characterization method for the hardened air void system in concrete. This study uses ASTM C457, “Standard Test Method for Microscopical Determination of Parameters of the Air-Void System in Hardened Concrete” as a baseline …
-
Air void clustering in concrete
Air void clustering around coarse aggregate in concrete has been identified as a potential source of low strengths in concrete mixes by several Departments of Transportation around the country. Research was carried out to (1) develop a quantitative measure of air void clustering around aggregates, …
-
Air entrainment and variation of air void system in fresh concrete
<p>An adequate air void system in concrete is critical to its freeze-thaw (F-T) durability. With an effective air void system, concrete can survive longer in a wet climate with F-T cycles. Over the years, researchers have focused on fresh air content and the hardened air void system, but little …
-
Quantifying air-void distribution and associated uncertainty in fresh and hardened concrete
… Powers recommended entraining a well-distributed air-void system (comprised of equally spaced, small air voids) through the cementitious paste to minimize frost damage in PCCP. There are several methods to measure total air content in fresh concrete, such as ASTM C231 (volumetric air content using …
-
Analysis of air-void system in hardened concrete from a three-dimensional perspective
… can be greatly enhanced by entrainment of small air bubbles in the cement paste. When the volume and distribution of the entrained air is properly controlled, the microstructure is protected from pressure exerted by freezing water. ASTM C457 “Standard Test Method for Microscopical Determination …
-
Local calibration of the MEPDG prediction models for pavement rehabilitation and evaluation of top-down cracking for Oregon Roadways
… tests on asphalt binder and aggregate gradation analysis. The FWD and DCP tests indicated that top-down cracked pavement sections were structurally sound, even some of the sections with top-down cracking showed better structural capacity compared to non-cracked sections. The study also found that …
-
Fractionated reclaimed asphalt pavement as a coarse aggregate replacement in a ternary blended concrete pavement
… dosages), the unit weight decreased, and the air content remained relatively unaffected although somewhat more variable. A hardened air void analysis revealed acceptable parameters for freeze/thaw durability, but the hardened air content was found to be higher than measured volumetric fresh …
-
Effect of secondary copper slag as supplementary cementitious material and aggregate replacement on strength, hydration, microstructure and durability of ultra-high performance concrete
… concrete and leaving only a limited amount of air voids. Therefore, when the vacuum mixing is applied, only remaining air bubbles can be removed. However, by applying heat treatment to the mixtures, a significant reduction in total porosity, macropores+entrained air voids, and capillary pores …