Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"All-ceramic crowns"”.

  1. Comparison of Scanning Accuracy of PVS Impressions of Multiple Tooth Preparations with Different Tapers Using Two Benchtop Scanners: An In-Vitro Study

    Introduction: The all-ceramic-crown manufacturing techniques have evolved significantly since the very first porcelain jacket crown was introduced by Dr. Charles Land in 1903 1. With the advancement in computer-aided design and computer-aided manufacturing (CAD CAM) technologies, along with new …

    buffalo Repository record for Comparison of Scanning Accuracy of PVS Impressions of Multiple Tooth Preparations with Different Tapers Using Two Benchtop Scanners: An In-Vitro Study (opens in a new tab)

  2. High elastic modulus nanopowder reinforced resin composites for dental applications

    … dollars a year on the market. Among them, all-ceramic dental crowns draw more and more attention and their popularity has risen because of their superior aesthetics and biocompatibility. However, their relatively high failure rate and labor-intensive fabrication procedure still limit their …

    maryland Repository record for High elastic modulus nanopowder reinforced resin composites for dental applications (opens in a new tab)

  3. Marginal Adaptation of CAD/CAM Hybrid Ceramic Crowns Made on Preparations With and Without Surface Finishing

    … vitro study evaluated the marginal adaptation of ceramic crowns fabricated with a chair-side CAD/CAM system on preparations completed with and without surface finishing to identify if finishing preparation protocols affect the marginal fit. The null hypothesis was that there was no difference in …

    penn Repository record for Marginal Adaptation of CAD/CAM Hybrid Ceramic Crowns Made on Preparations With and Without Surface Finishing (opens in a new tab)

  4. Marginal staining between pressed lithium disilicate ceramic crowns and direct restorative materials by various fluids : a microleakage study.

    … the two dental restorations (resin composite and ceramic crown) may be more susceptible to microleakage and fluid staining, reducing restoration longevity. In this study, 80 extracted molars received indirect restoration margins finished on different direct restorative materials (resin-modified …

    louisville Repository record for Marginal staining between pressed lithium disilicate ceramic crowns and direct restorative materials by various fluids : a microleakage study. (opens in a new tab)

  5. Effect of Air-Abrasion on the retention of zirconia ceramic crowns luted with different cements before and after artificial aging

    … on the retention of CAD/CAM produced zirconia ceramic crowns cemented with three different types of cement. The influence of artificial aging was also tested. Methods: Extracted human premolars were prepared for all-ceramic crowns. CAD/CAM zirconia crowns were manufactured. Crowns were …

    cau-kiel Repository record for Effect of Air-Abrasion on the retention of zirconia ceramic crowns luted with different cements before and after artificial aging (opens in a new tab)

  6. Endodontic access in all-ceramic dental restorative crown materials

    … crown in situ. Increasing trends indicate that all-ceramic crowns are provided as the preferred restorative option to metal-ceramic crowns. This is because modern all-ceramic restorations can now provide excellent aesthetic solutions combined with high mechanical strength properties, compared …

    cork Repository record for Endodontic access in all-ceramic dental restorative crown materials (opens in a new tab)

  7. The Influence of Full Coverage Restorations On Pulp Vitality: A Ten-Year Retrospective Study

    … and Nomenclature. RESULTS: Out of 88,409 crowns placed, 8.86% were all-metal, 41.40% were all-porcelain and 49.64% were porcelain fused to metal (PFM). The majority of all untoward events for all groups consisted of non-surgical root canal therapy. The probability of survival of all teeth …

    marquette Repository record for The Influence of Full Coverage Restorations On Pulp Vitality: A Ten-Year Retrospective Study (opens in a new tab)

  8. Marginal fit of lithium disilicate crowns : a three-dimensional analysis

    … the marginal fit of lithium disilicate (LDS) crowns fabricated with digital impression and manufacturing (termed “DD”), digital impression and traditional pressed manufacturing (termed “DP”), and traditional impression and manufacturing (termed “TP”). Methods: Tooth #15 was prepared for …

    ubc Repository record for Marginal fit of lithium disilicate crowns : a three-dimensional analysis (opens in a new tab)

  9. Influence Of Surface Treatment Of Y-Tzp And Luting Cements On Retention Of Y-Tzp Crown

    … due to improved esthetics, often select all ceramic crowns. Zirconium Oxide has been utilized for many years to full fill the requirement of esthetics, high mechanical properties and biocompatibility. The purpose of this study is to evaluate the effect of different surface treatments and …

    uab Repository record for Influence Of Surface Treatment Of Y-Tzp And Luting Cements On Retention Of Y-Tzp Crown (opens in a new tab)

  10. Fracture Strength of 3D Printed Resin Interim Fixed Partial Dentures Varying Connector Sizes

    … was prepared for first premolar and molar all ceramic crowns with 0.5mm chamfer margins and total 6-degree convergence angle. The model was scanned via intraoral scanner (3Shape, Trios 4) and uploaded into CAD software (Exocad). 3-unit FPD with various connector sizes 9mm^2, 12mm^2, and …

    tamu Repository record for Fracture Strength of 3D Printed Resin Interim Fixed Partial Dentures Varying Connector Sizes (opens in a new tab)

  11. Marginal gap and internal fit of CEREC e.max and Celtra Duo crowns

    … chipping of e.max (EM) and Celtra Duo (CD) all-ceramic crowns fabricated using chairside economical restoration of esthetic ceramics (CEREC) system. Material and Methods: Tooth # 15 was prepared for an all-ceramic crown on an ivorine typodont. A total of 15 CD and 15 EM crowns were designed …

    ubc Repository record for Marginal gap and internal fit of CEREC e.max and Celtra Duo crowns (opens in a new tab)

  12. Fatigue behaviour and failure modes of monolithic CAD/CAM hybrid-ceramic and all-ceramic posterior crown restorations

    … modes of a novel CAD/CAM experimental hybrid-ceramic material and to compare it with two monolithic all-ceramic CAD/CAM materials (Vita Mark II and IPS e.max CAD) in a standardized molar crown model. The correlation between fracture load, cement thickness, crack length, and contact area size …

    freiburg-diss Repository record for Fatigue behaviour and failure modes of monolithic CAD/CAM hybrid-ceramic and all-ceramic posterior crown restorations (opens in a new tab)

  13. Effects of Long-Term Simulated RPD Clasp Attachment/Detachment on Retention and Wear for Two Clasps and Three Abutment Material Surfaces

    … surface materials (enamel, composite, CAD/CAM ceramic crown) during long-term simulation of attachment and detachment, and to measure the loss of retention and wear after 16,000 simulated cycles of attachment-detachment. Forty-eight models were constructed by placing either an upper first …

    cau-kiel Repository record for Effects of Long-Term Simulated RPD Clasp Attachment/Detachment on Retention and Wear for Two Clasps and Three Abutment Material Surfaces (opens in a new tab)

  14. Fracture Toughness Testing of 3, 4, and 5 mol% Yttria Stabilized Zirconia Ceramics Using the Single Edge V-notch Beam Test

    … and lithium discilicate are the most popular ceramic restorative materials today. The use of monolithic zirconia ceramics had been often limited to posterior restorations due to their opaque optical properties. Many manufacturers have developed more translucent zirconia stabilized by 4 and 5 …

    uconn-diss Repository record for Fracture Toughness Testing of 3, 4, and 5 mol% Yttria Stabilized Zirconia Ceramics Using the Single Edge V-notch Beam Test (opens in a new tab)

  15. Untersuchungen zum Einfluss von Befestigungsmodus und Alterung auf die Bruchfestigkeit von Cercon-Kronen

    … weitere 10 Proben von 40.000 Temperaturwechseln. Alle Proben wurden auf der Zwick Universalprüfmaschine Bruchlasttests unterzogen. Nach statistischer Auswertung lässt sich weder für die Art der Befestigung noch für die Anzahl an Temperaturwechseln ein signifikanter Unterschied in den …

    fu-berlin Repository record for Untersuchungen zum Einfluss von Befestigungsmodus und Alterung auf die Bruchfestigkeit von Cercon-Kronen (opens in a new tab)

  16. Klinische Bewährung von Procera® AllCeram Kronen nach einem Zeitraum von 10 Jahren

    Procera® AllCeram Kronen werden seit 1997 an der Zahnklinik der Freien Universität in Berlin hergestellt, eingesetzt und evaluiert. Bei insgesamt 36 Patienten wurden 74 Kronen mit diesem Herstellungsverfahren eingegliedert und 2009, nach einem Zeitraum von zwölf Jahren unter Funktion für diese …

    fu-berlin Repository record for Klinische Bewährung von Procera® AllCeram Kronen nach einem Zeitraum von 10 Jahren (opens in a new tab)