Microcontroller Based Particulate Matter Monitors Utilising the Alphasense OPC-N3
… development work is required. In this paper, the Alphasense OPC-N3 optical particle sensor is used together with an Ar- duino UNO microcontroller to create low-cost easy-to-use particulate monitors. Two versions were developed; a portable monitor for measuring the personal exposure to particulate …
-
Assessing the Impact of Internal Flow Dynamics on Detection Region Concentrations of Low-Cost Optical Particle Counters
… variability. Furthermore, for the simulation of Alphasense OPC, the average percentage deviation of the regional concentration from the inlet was 19% for the velocity inlet boundary condition and 11% for the pressure inlet boundary condition, highlighting the impact of boundary conditions on …
-
Evaluation of low-cost optical particle counters for environmental and occupational exposures
… available low-cost sensors (OPC-N3 from Alphasense, SPS30 from Sensirion, AirBeam2 from HabitatMap, and PMS A003 from Plantower) for measuring mass concentrations of particulate matter in environmental and occupational settings. The mass concentrations (PM1, PM2.5, PM4, and PM10) reported …
-
Laboratory and Field Evaluations of the GeoAir2 Air Quality Monitor for Indoor Exposure
… low-cost optical particle counter (OPC-N3 by Alphasense) were used. First, the devices were tested with two different aerosols, salt and Arizona road dust, with steady states measured by a medium-cost pDR-1500 aerosol sensor. The pDR-1500 is accompanied by a filter to provide gravimetric …
-
Evaluation and Calibration of Coupled Low-Cost Particulate Matter Sensors
… PM sensors–the Plantower PMS5003 and the Alphasense OPC-N3–to measure both PM2.5 and PMCoarse. QuantAQ purportedly uses the PMS5003 to estimate the mass concentration of particles below the detection limit of the OPC-N3; in this case, the MOD-PM uses both the PMS5003 and OPC-N3 to …
-
Media and Devices for Management of Airborne Contaminants
… conditions. Five of the sensors used were Alphasense B4 series low-cost gas sensors, for monitoring CO, SO2, NO, NO2, and a combination NO2 and ozone sensor. These were electrochemical type sensors. The sixth sensor was a non-dispersive infrared sensor for measuring CO2. The pollutant gas …
-
Media and Devices for Management of Airborne Contaminants
… conditions. Five of the sensors used were Alphasense B4 series low-cost gas sensors, for monitoring CO, SO2, NO, NO2, and a combination NO2 and ozone sensor. These were electrochemical type sensors. The sixth sensor was a non-dispersive infrared sensor for measuring CO2. The pollutant gas …
-
Media and Devices for Management of Airborne Contaminants