The detection and documentation of bruises using alternate light source
… victim comes forward to report an assault, only slight redness may be observed, which may not accurately represent the injury severity. This study focuses on the use of Alternate Light Source (ALS) to detect and document such injuries more effectively. Following institutional approval, blunt …
-
Seminal stain fluorescence using three alternate light source-barrier filter combinations on six different colors of cotton fabrics
… are fluorescence and chemical examinations. An alternate light source (ALS), which causes semen to fluoresce under different wavelengths, is an established technique that utilizes converted light for the detection of latent stains. The other method relies on chemically identifying the presence …
-
Enhancement of Lumicyano™-fumed latent fingerprints with laboratory processing techniques
… will immediately fluoresce with the use of an alternate light source following fumigation with the Lumicyano kit; therefore, additional post-treatment with chemical enhancing reagents is not necessary. The elimination of the subsequent chemical processing step is more cost-effective, time …
-
Exploration into the efficient recovery and probabilistic interpretation of DNA from laundered semen stains
… semen stains that may not fluoresce under an alternate light source. The M-Vac® allowed for DNA to be recovered, with quantities ranging from 1.4x10-4 to 0.014 ng/μL. Despite the low quantities of DNA recovered after laundering, 16 samples generated ≥ 80% of a profile matching the male donor, …
-
Evaluation of SpermTracker paper and spray for the visualization of seminal stains
… both with the naked eye and with the aid of an alternate light source. STK® SpermTracker-Lab proved to be the most sensitive, closely followed by the AP-Spot test. STK® SpermTracker-Spray was least effective at detecting semen stains, however, many of the negative results obtained with …
-
Effects of heat and burning on testing methods for blood and semen
… Semen stains exhibited fluorescence using an alternate light source after limited exposure to all temperatures, but more successfully on denim and synthetic leather than on carpet. AP Spot test was successful on all semen stains on synthetic leather, and on a number of samples on denim and …
-
Semen detectability within neat and mixed biological stains on reusable absorbent underwear
… underwear to serve as a substrate control, Knix Light Leakproof® menstrual underwear, Knix Super Leakproof® menstrual underwear, and Wearever® incontinence underwear. Biological samples consisted of semen, semen-blood mixtures, and semen-urine mixtures. To evaluate the persistence of biological …
-
Evaluation of Zar-Pro lifting strips as a mapping technique for the recovery of DNA from biological stains
Forensic alternate light sources, commonly known as ALS, use various wavelengths of light, such as blue light, ultraviolet (UV), and infrared (IR), to screen for latent biological stains on items. It works on the principle of fluorescence and relies on the ability to visualize the fluorescence …
-
Development of a thiol-reactive fluorescent probe for the identification of human spermatozoa
… semen include preliminary methods such as an alternate light source (ALS) and color tests which test for the presence of acid phosphatase (AP). Confirmatory methods for identifying semen include the microscopic identification of spermatozoa which typically use staining methods such as the …
-
Innovative techniques for the localization of seminal stains and the identification of spermatozoa
… of evidence are first visualized under white light followed by an Alternate Light Source (ALS) if no stains are readily visible. When potential semen stains are localized, preliminary chemical testing can be performed to guide the analyst to conduct further testing or to disregard a certain …
-
Development of low-cost photoacoustic imaging systems and their applications
… PAI, an object is irradiated with a short-pulsed light source. The light energy is absorbed by the object and is partially converted into heat energy, leading to local temperature rise and subsequently pressure rise due to thermoelastic expansion. The pressure waves propagate as ultrasound waves …
-
Migration patterns of seminaI fluid components and spermatozoa in semen stains exposed to water and blood
… blood was dry, the swatches were viewed with an alternate light source (ALS) at 450 nm using orange barrier filter goggles. Three-millimeter fabric punches were collected from each swatch in at least thirteen locations (one from the center of the stain and four at 1 cm, 4 cm, and 7 cm from the …
-
Degradation of seminal components in different environmental conditions
… workflow (from visual examination including an alternate light source (ALS) and AP testing to PSA or Sg testing followed by a microscopic examination for sperm cells) to ensure laboratory resources are being used in a proper manner with minimal waste of both time and resources. However, this …
-
Effects of decomposition on the recoverability of biological fluid evidence
… to show a decrease in fluorescence using an alternate light source (ALS) by day 3, and some areas of fluorescence occurred in a different location, indicating that the soluble components had diffused outward from the original region of deposition (ORD). Results for acid phosphatase (AP) and …