Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 7 of 7 for “"Alternate path method"”
-
Reliability Assessment of Alternate Path Method for Structural Steel Connections
… the adjoining structural members. The resistance method known as Alternate Path Method (APM) outlined by the UFC 04-23 (2013) is implemented to resist the progressive collapse failure. Steel moment frames are used to redistribute the load after a column is notionally removed. This study analyzes …
-
Evaluation of Progressive Collapse Resistance of RC Framed Buildings Using Alternate Path Method
… concrete (RC) framed structures using the Alternate Path Method (APM), a widely used threat-independent approach aimed at ensuring building stability after localized structural damage. Progressive collapse, characterized by disproportionate structural failure following the loss of one or …
-
Effect of retrofit strategies on mitigating progressive collapse of multistorey steel frame structures
… collapse response was investigated using the Alternate Path Method (APM) recommended in the United States' General Service Administration (GSA 2003) and Department of Defense (DoD 2005) guidelines. Nonlinear dynamic analysis for progressive collapse is done as a precise tool for evaluation of …
-
Robustness and Retrofit Strategies for Seismically-Designed Multistory Steel Frame Buildings Prone to Progressive Collapse
… plan; each bay has a span of 6 meters. Alternate Path Method (APM) recommended by GSA 2003 guidelines is adopted to evaluate the robustness of the buildings against progressive collapse. Three-dimensional models of the buildings are built using the Extreme Loading for Structures (ELS) …
-
Effects of Frame Configuration on Progressive Collapse Performance ofReinforced Concrete Buildings
… and laboratory specimens. Themodels followed the alternate path method as recommended in progressive collapse guidelines,with nonlinear dynamic analysis as the primary procedure. Linear static and nonlinear staticanalyses were also used for comparison. The first set of parametric studies utilized …
-
Structural behaviour of precast concrete frames subject to column removal scenarios
… collapse. Among the design approaches, alternate path method tends to prevent the spread of local damage through mobilisation of compressive arch action (CAA) and catenary action in the bridging beam and the floor system. However, development of alternate load path is contingent on …
-
EXPERIMENTAL AND ANALYTICAL ASSESSMENT ON THE PROGRESSIVE COLLAPSE POTENTIAL OF EXISTING BUILDINGS
<p>Progressive collapse has been of an increasing concern in the structural engineering community, especially since the collapse of the World Trade Center towers in 2001. As a result of increasing catastrophic events in recent years, the prevention of progressive collapse is becoming a requirement …