Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 120 for “"Alternator"”.

  1. A Tennessee Alternator

    … Westinghouse motor. It is known as the R. H. Alternator and is driven by a direct connected Westinghouse motor. The following data will describe the machine.</p>

    ut-knoxville Repository record for A Tennessee Alternator (opens in a new tab)

  2. Anticommutative derivation alternator rings

    … rings are called anticommutative derivation alternator rings. In Section II, we shall show some basic properties of the multiplication in rings of this type. In Section III, we shall show the structure of a special type of simple anticommutative derivation alternator rings. Finally, in …

    iastate Repository record for Anticommutative derivation alternator rings (opens in a new tab)

  3. Alternator analysis and inductance parameters

    … thesis deals with several aspects of rotating alternators. The subject of inductance parameter determination is discussed. Specific emphasis is placed on methods of bounding the values of the inductance of the damper or amortisseur winding. In addition, the fault analysis using the conservation …

    ttu Repository record for Alternator analysis and inductance parameters (opens in a new tab)

  4. Turbo-alternator modeling and control

    This thesis is concerned with the problem of designing a constant coefficient feedback controller that will allow arbitrary pole placement of a single synchronous generator connected through a reactance to an infinite bus. The nonlinear system model is derived and linearized. The controller …

    rice Repository record for Turbo-alternator modeling and control (opens in a new tab)

  5. Oscillographic Study of Alternator Short Circuits

    … transient peak during a short-circuit of an alternator, and to verify certain theoretical equations with actual experimental figures. This experiment is a continuation of the studies begun by students at Cornell University. The work described in this paper was done under somewhat different …

    ut-knoxville Repository record for Oscillographic Study of Alternator Short Circuits (opens in a new tab)

  6. A protection scheme for alternator fields

    … appearing across the field of a three-phase alternator generated by negative-phase-sequence currents due to unbalanced conditions. Readings were taken of the times required for operation of the relay for various conditions of unbalance. Statistical studies were made to enable time predictions …

    vt Repository record for A protection scheme for alternator fields (opens in a new tab)

  7. Determining Alternator Reactances from Load Test Data

    It is the purpose of this paper to establish equations, with some assumptions, for calculating the reactances of a synchronous generator, using load test data, and to analyze the results. For this purpose a report on power angle measurements on Unit No. 8, at Station 16, (Waukegan) of The …

    sdstate Repository record for Determining Alternator Reactances from Load Test Data (opens in a new tab)

  8. Control of an integrated starter/alternator in automotive applications

    The master thesis aims to develop an electric drive system controlling a specific type of electric machine. A part of the master thesis has been to evaluate and analyze whether the proposed machine can perform the desired tasks for this system. The machine has also been analyzed and measurements …

    chalmers Repository record for Control of an integrated starter/alternator in automotive applications (opens in a new tab)

  9. A high power interior permanent magnet alternator for automotive applications.

    … applications in power generation, e.g. as an alternator in automotive electrical systems and in renewable energy systems such as small-scale wind turbines. The thesis starts from a study of the behaviour of the interior PM machine while generating into a three-phase resistive load and also …

    adelaide Repository record for A high power interior permanent magnet alternator for automotive applications. (opens in a new tab)

  10. Two-stage thermoacoustic electricity generator with push-pull linear alternator

    … generator prototype with a push-pull linear alternator. The push-pull coupling offers a solution to run the looped-tube thermoacoustic engine at high acoustic impedance using one alternator. The novel configuration of the engine consists of two identical half-wavelength stages with an …

    whiterose Download PDF for Two-stage thermoacoustic electricity generator with push-pull linear alternator (opens in a new tab)

  11. Direct torque controlled induction machines for integrated starter/alternator system

    An integrated starter/alternator (ISA) has been proposed for the future 42 V PowerNet, which combines both starter and alternator functions into a single electrical machine with bidirectional power flow ability. This thesis presents analysis, design, modeling and experimental results of the direct …

    unsw Repository record for Direct torque controlled induction machines for integrated starter/alternator system (opens in a new tab)

Page 1 of 6