Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 28 for “"Alternators"”.

  1. Integrated electric alternators/active filters

    … the concept of active filtering into the alternators are proposed. Wind energy, due to its free availability and its clean and renewable character, ranks as the most promising renewable energy resource that could play a key role in solving the worldwide energy crisis. An Integrated …

    tamu Repository record for Integrated electric alternators/active filters (opens in a new tab)

  2. Air-Gap Wound Alternators for Large-Scale Power Generation

    The airgap-wound or slotless alternator is similar to the conventional type of alternator used for central power generation, but the windings of both the fixed and rotating components are situated in the gap normally separating the two, rather than in slots milled into the steel surfaces. It is …

    aston Download PDF for Air-Gap Wound Alternators for Large-Scale Power Generation (opens in a new tab)

  3. A Model Based Fault Detection and Diagnosis Strategy for Automotive Alternators

    Faulty manufactured alternators lead to commercial and safety concerns when installed in vehicles. Alternators have a major role in the Electrical Power Generation System (EPGS) of vehicles, and a defective alternator will lead to damaging of the battery and other important electric accessories. …

    mcmaster Repository record for A Model Based Fault Detection and Diagnosis Strategy for Automotive Alternators (opens in a new tab)

  4. Fault Detection and Identification of Vehicle Starters and Alternators Using Machine Learning Techniques

    … fault signatures for vehicle starter motors and alternators. A fault detection and identification system has been developed to identify fault types for end-of-line testing of motors. However, labels are relatively difficult to obtain, expensive, time consuming and require experienced humans, …

    mcmaster Repository record for Fault Detection and Identification of Vehicle Starters and Alternators Using Machine Learning Techniques (opens in a new tab)

  5. Industrial Extended Multi-Scale Principle Components Analysis for Fault Detection and Diagnosis of Car Alternators and Starters

    … of electrical components of cars such as alternators and starters is an important consideration due to both commercial and safety reasons. The focus of this research is to develop a complete Fault Detection and Diagnosis (FDD) solution for alternators and starters for their implementation …

    mcmaster Repository record for Industrial Extended Multi-Scale Principle Components Analysis for Fault Detection and Diagnosis of Car Alternators and Starters (opens in a new tab)

  6. Characteristics of three phase rectifiers with anode reactors, for application to the problem of electronic excitation of large synchronous alternators

    The object of this Investigation is to find out the characteristics of a three phase rectifier with reactance in the anode leads operating near short circuit, and to see if the findings may lead to the design of more efficient or less expensive electronic exciters for large synchronous generators.

    rice Repository record for Characteristics of three phase rectifiers with anode reactors, for application to the problem of electronic excitation of large synchronous alternators (opens in a new tab)

  7. The analysis of complex wave forms taken from different alternators and transformers in the electrical engineering laboratory at Virginia Polytechnic Institute

    Since the work that the writer was engaged in was primarily concerned with finding the equations of the different wave forms and not in the results of what caused distortions in the wave suggestions may be offered in the way of advice to following investigators by the following remarks: (1) Observe …

    vt Repository record for The analysis of complex wave forms taken from different alternators and transformers in the electrical engineering laboratory at Virginia Polytechnic Institute (opens in a new tab)

  8. Design and Testing of a Thermoacoustic Power Converter

    … heat engine with a pair of linear alternators to produce 100 watts of electricity from a heat input. It operates with helium at 450 psig internal pressure and a hot side temperature of 1200F. Through thermoacoustic phenomena, these conditions sustain a powerful pressure wave at a …

    gatech Repository record for Design and Testing of a Thermoacoustic Power Converter (opens in a new tab)

  9. The effects of non-sinusoidal wave forms on incandescent lamp characteristics

    … direct current motor directly coupled to five alternators. These alternators produced frequencies of 60, 120, 180, 300, and 420 cycles per second respectively. The output of the alternators were connected in series as desired by means of a specially designed switch board. The alternator fields …

    vt Repository record for The effects of non-sinusoidal wave forms on incandescent lamp characteristics (opens in a new tab)

  10. Wind-system performance optimization using microprocessor control

    … electrical power by the use of synchronous alternators driven by fixed-pitch impellers, they often do not extract maximum possible energy from the wind. This is because they do not maintain an optimal rotational speed in relation to wind speed. Therefore, their efficiency is good only over a …

    iastate Repository record for Wind-system performance optimization using microprocessor control (opens in a new tab)

  11. Alternator analysis and inductance parameters

    … thesis deals with several aspects of rotating alternators. The subject of inductance parameter determination is discussed. Specific emphasis is placed on methods of bounding the values of the inductance of the damper or amortisseur winding. In addition, the fault analysis using the conservation …

    ttu Repository record for Alternator analysis and inductance parameters (opens in a new tab)

  12. Implementations of Fuzzy Adaptive Dynamic Programming Controls on DC to DC Converters

    … wave energy sources, rectified voltage from alternators, and so forth. Hence, the need for improving its control algorithm is inevitable. Many algorithms are applied to DC to DC converters. This thesis designs fuzzy adaptive dynamic programming (Fuzzy ADP) algorithm. Also, this thesis …

    unt Repository record for Implementations of Fuzzy Adaptive Dynamic Programming Controls on DC to DC Converters (opens in a new tab)

  13. Cultural coping strategies of involuntary minority and non-minority chairpersons at the university level

    … types he classified as assimilators, emissaries, alternators, reaffiliated, ivy-leaguers, regulars, ambivalents, and encapsulated; T-test scores were utilized at the.05 level to determine statistical significance. The t-scores indicated that part of Ogbu's concept (emissaries, reaffiliated, …

    unlv Repository record for Cultural coping strategies of involuntary minority and non-minority chairpersons at the university level (opens in a new tab) Download PDF for Cultural coping strategies of involuntary minority and non-minority chairpersons at the university level (opens in a new tab)

  14. A method for determining transient stability in power systems

    … phase ac power system consisting of synchronous alternators interconnected by transmission lines and other items of electrical transmission equipment, a method is presented which determines the stability of the system when subjected to a three phase symmetrical fault, and to the subsequent …

    must-thes Repository record for A method for determining transient stability in power systems (opens in a new tab)

  15. Aircraft photovoltaic power-generating system.

    … electromechanical power-generating systems (alternators and generators). In addition to improvements in aircraft performance, significant aircraft fuel- and weight-saving advantages are projected.

    arizona-thes Repository record for Aircraft photovoltaic power-generating system. (opens in a new tab)

  16. Low voltage electrolytic capacitor pulse forming inductive network for electric weapons

    … high-energy pulses of many megawatts. Pulsed alternators potentially have the same maintenance issues as other motor-generator sets, so a solid-state system would be desirable, but high voltage capacitor systems are not robust enough for the field. We propose here a Low Voltage Electrolytic …

    nps Repository record for Low voltage electrolytic capacitor pulse forming inductive network for electric weapons (opens in a new tab)

  17. Purkeys' 25 Year Journey

    … They began Purkeys by supplying batteries, alternators and other parts of a heavy-duty vehicle’s electrical system to one customer, JB Hunt. As the company grew they began to be known across the nation for finding creative solutions to the electrical issues trucking fleets faced. Bruce led …

    arkansas Repository record for Purkeys' 25 Year Journey (opens in a new tab)

  18. Two-stage thermoacoustic electricity generator with push-pull linear alternator

    … of a four-stage engine with two push-pull linear alternators able to generate up to 269 W of electricity, theoretically.

    whiterose Download PDF for Two-stage thermoacoustic electricity generator with push-pull linear alternator (opens in a new tab)

Page 1 of 2