Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 105 for “"Amperometry"”.

  1. Thermal Desorption Amperometry of Hydrogen in Metals

    Fuel distribution, transportation, energy, and manufacturing applications need robust analyzers where critical engineering components can be compromised in service or during manufacturing by trace amounts of hydrogen. Measurements of hydrogen in metals are thus essential for the safety and …

    carleton Repository record for Thermal Desorption Amperometry of Hydrogen in Metals (opens in a new tab)

  2. Triple pulse amperometry: a method of detection of carbohydrates and alcohols for liquid chromatography

    <p>Application of a triple pulse waveform is described for the anodic detection of simple alcohols and carbohydrates at a platinum electrode. The execution of the waveform incorporates the cleaning and reactivation of the platinum electrode, by alternate anodic and cathodic polarization, with …

    iastate Repository record for Triple pulse amperometry: a method of detection of carbohydrates and alcohols for liquid chromatography (opens in a new tab)

  3. Neurochemical Monitoring in a Humanised Murine Model of Parkinson’s Disease using Amperometry and Microdialysis

    The main objective of this thesis was to elucidate an overall neurochemical signature of the progression of patient-specific Parkinson’s disease (PD) through the amperometric monitoring of nitric oxide (NO), oxygen (O2) and hydrogen peroxide (H2O2) coupled with microdialysis sampling. The …

    maynooth Download PDF for Neurochemical Monitoring in a Humanised Murine Model of Parkinson’s Disease using Amperometry and Microdialysis (opens in a new tab)

  4. Studies of reverse pulse amperometry at mercury electrodes and its application for cation-exchange chromatography

    <p>The application of reverse pulse amperometry (RPA) at a polarographic detector in a flow-injection system or in cation-exchange chromatography (CEC) allows accurate monitoring of trace metal ions in a fluid stream without the conventional requirement of deaeration. The technique of RPA is based …

    iastate Repository record for Studies of reverse pulse amperometry at mercury electrodes and its application for cation-exchange chromatography (opens in a new tab)

  5. Detection of metal ions in flow-analyzers by reverse pulse amperometry without interference from dissolved oxygen

    <p>Reverse pulse amperometry is introduced as an electroanalytical technique which, when applied with a mercury electrode, is capable of monitoring fluid streams for the presence of electroactive metal ions without the requirement of deaeration. The technique is based on the application of an …

    iastate Repository record for Detection of metal ions in flow-analyzers by reverse pulse amperometry without interference from dissolved oxygen (opens in a new tab)

  6. The Development of Coulostatic Charge Injection Techniques for High Performance Liquid Chromatography Analysis (Electrochemistry, Detection, Amperometry, Hplc)

    … pulses are used to mimic controlled potential amperometry. The single pulse technique gives detection limits of 2 x 10('-10) moles Pb(II) at a mercury electrode. Coulostatic pulse amperometry methods were used to quantitate 4 x 10('-11) moles of caffeic acid at a carbon paste electrode.

    uiuc Repository record for The Development of Coulostatic Charge Injection Techniques for High Performance Liquid Chromatography Analysis (Electrochemistry, Detection, Amperometry, Hplc) (opens in a new tab)

  7. KINETICS OF HETEROGENEOUS SOLID-LIQUID REDOX REACTIONS: THE REACTION BETWEEN MANGANESE DIOXIDE AND HALIDE IONS (AMPEROMETRY, FLOW INJECTION).

    … of the reaction mixture. I₂ was monitored using amperometry. Mn²⁺ was monitored by a novel application of flow injection analysis. A molecular mechanism was postulated which accounts for the complex pH dependence of the reaction and the inhibition of the reaction under conditions of lower …

    arizona-thes Repository record for KINETICS OF HETEROGENEOUS SOLID-LIQUID REDOX REACTIONS: THE REACTION BETWEEN MANGANESE DIOXIDE AND HALIDE IONS (AMPEROMETRY, FLOW INJECTION). (opens in a new tab)

  8. High-Density Neurochemical Microelectrode Array to Monitor Neurotransmitter Secretion

    … to bodily function, memory, and emotions. Using amperometry, an electrochemical technique that directly detects electroactive molecules, the sub-millisecond dynamics of exocytosis are revealed and the modulation of neurotransmitter secretion due to neurodegenerative diseases or pharmacological …

    ucf Repository record for High-Density Neurochemical Microelectrode Array to Monitor Neurotransmitter Secretion (opens in a new tab)

  9. Rapidly Scanning Coulostatic Liquid Chromatography/electrochemistry Combined With Conventional Amperometric Detection in a Series Dual-Electrode Cell

    … technique of rapidly scanning coulostatic pulse amperometry is combined with conventional fixed-potential amperometry in a series dual-electrode cell to create a novel detector for high performance liquid chromatography. After a preliminary period of electrode evaluation, a flow cell was designed …

    uiuc Repository record for Rapidly Scanning Coulostatic Liquid Chromatography/electrochemistry Combined With Conventional Amperometric Detection in a Series Dual-Electrode Cell (opens in a new tab)

  10. Interferences of N-Chloroorganic Compounds in Free Chlorine Determination

    … the free chlorine determination by amperometry. These N-chloroorganic compounds were also studied for the recovery in response by the indicator electrode in amperometric titrimetry. The total chlorine content of the chloroaldimines derived from the chlorination of the amino acids, …

    odu Repository record for Interferences of N-Chloroorganic Compounds in Free Chlorine Determination (opens in a new tab)

  11. Activity of methanol electro-oxidation at PtRu materials at temperatures in the range of 23°C to 70°C

    … Cyclic voltammetry and constant potential amperometry were used to characterize the catalyst materials and study the methanol reaction kinetics. Measurements were performed at temperature in the range of 23°C to 70°C. The following catalyst materials were employed: PtRu black containing 50 …

    ttu Repository record for Activity of methanol electro-oxidation at PtRu materials at temperatures in the range of 23°C to 70°C (opens in a new tab)

  12. Berlyno mėlynojo pagrindu suformuotų biologinių jutiklių taikymas kenksmingų jonų nustatymui /

    … investigated for Hg2+ ions determination using amperometry in pH 7 buffer solution and tap water as well as using impedimetric measure in pH 7 buffer solution. The experiment using amperometry method shows that the Hg2+ concentration can be successfully determined in the interval from 1000 …

    vilnius Repository record for Berlyno mėlynojo pagrindu suformuotų biologinių jutiklių taikymas kenksmingų jonų nustatymui / (opens in a new tab)

  13. Amperometric Characterization of Nanosecond Electric Pulse-Evoked Exocytosis in Adrenal Chromaffin Cells: Custom Experimental Setup and Spike Detection Software

    … fusion events in real time using carbon fiber amperometry and to characterize the kinetic and temporal features of the NEP-evoked amperometric responses. A major technical challenge in implementing amperometry with high intensity NEP stimulation is protecting the highly sensitive amplifier …

    unr Repository record for Amperometric Characterization of Nanosecond Electric Pulse-Evoked Exocytosis in Adrenal Chromaffin Cells: Custom Experimental Setup and Spike Detection Software (opens in a new tab) Embargoed until 2027-09-05

  14. Development of a cell free system for analysis of the mechanisms of exocytosis using total internal reflectance microscopy

    … and these include capacitance measurements, amperometry and single-cell imaging. Reconstitution from defined components of the steps leading to exocytosis has not yet been achieved, whereas the investigation of the actual exocytotic event is well described. Access to the cytosolic components …

    edinburgh Repository record for Development of a cell free system for analysis of the mechanisms of exocytosis using total internal reflectance microscopy (opens in a new tab)

  15. Surface Modified CMOS IC for Electrochemical Characterization of Living Cell Transmitter Release

    … as Parkinson’s disease and Alzheimer’s disease. Amperometry detects neurotransmitters released through exocytosis by their oxidation at a polarizable electrode. The resulting oxidation current or amperometric spike provides information about the number of released neurotransmitters from a single …

    cornell Repository record for Surface Modified CMOS IC for Electrochemical Characterization of Living Cell Transmitter Release (opens in a new tab)

  16. ELECTROCHEMICAL DETECTION AND CATALYTIC OXIDATION OF AROMATIC POLLUTANTS IN WASTEWATER

    … sensors based on square wave voltammetry and amperometry for phenol and aniline detection in real time. Such information is important for process optimization and minimization of chemical usage. With a pre-concentration step with an 0.8-V applied voltage on a graphite electrode, 0.1 ppb of …

    nus Repository record for ELECTROCHEMICAL DETECTION AND CATALYTIC OXIDATION OF AROMATIC POLLUTANTS IN WASTEWATER (opens in a new tab) Download file for ELECTROCHEMICAL DETECTION AND CATALYTIC OXIDATION OF AROMATIC POLLUTANTS IN WASTEWATER (opens in a new tab)

  17. Some analytical studies on sensors and speciation

    … mono-phenols and glucose using amperometry. A new immobilisation procedure involving the use o f spectroscopic graphite and silicone grease is also described. Anodic Stripping Voltammetry was employed to illustrate the detection o f Pb(II) and Cu(II) at lichen-modified carbon …

    dcu Download PDF for Some analytical studies on sensors and speciation (opens in a new tab)

  18. A study of aluminium, its indirect electrochemical detection and interaction with natural organic matter in water treatment

    … by indirect analysis through oxidation by amperometry of DASA (+0.6V vs Ag/AgCl/KCl at a glassy carbon electrode) or by the reduction of the Al-DASA complex through adsorptive cathodic stripping voltammetry (-1.15V vs Ag/AgCl at a mercury film electrode). An automated flow injection …

    adelaide Repository record for A study of aluminium, its indirect electrochemical detection and interaction with natural organic matter in water treatment (opens in a new tab)

  19. Development and application of electrochemical dithiothreitol (DTT) assay for analysis of particulate matter

    … analysis of PM in air samples. Flow injection amperometry was used as the primary electrochemical method. Amperometry was performed using a CH Instruments potentiostat and commercially available DropSens modified carbon screen printed electrodes (SPE's) with a DropSens impinging jet flow cell, …

    colostate Repository record for Development and application of electrochemical dithiothreitol (DTT) assay for analysis of particulate matter (opens in a new tab)

Page 1 of 6