Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"Analyte Transport"”.

  1. Comparing Theory and Experiment for Analyte Transport in the First Vacuum Stage of the Inductively Coupled Plasma Mass Spectrometer

    … the ICP-MS, the true goal is to improve its analyte detection capabilities. In this work, we develop a model for adding analyte to FENIX and compare it to previously collected experimental data. We also calculate how much ambipolar fields, plasma sheaths, and electron-ion recombination affect …

    byu Repository record for Comparing Theory and Experiment for Analyte Transport in the First Vacuum Stage of the Inductively Coupled Plasma Mass Spectrometer (opens in a new tab) Download PDF for Comparing Theory and Experiment for Analyte Transport in the First Vacuum Stage of the Inductively Coupled Plasma Mass Spectrometer (opens in a new tab)

  2. Comparing Theory and Experiment for Analyte Transport in the First Vacuum Stage of the Inductively Coupled Plasma Mass Spectrometer

    … algorithm as coded in FENIX is used to model the transport of trace ions in the first vacuum stage of the inductively coupled plasma mass spectrometer. Haibin Ma of the Farnsworth group at Brigham Young University measured two radial trace density profiles: one 0.7 mm upstream of the sampling cone …

    byu Repository record for Comparing Theory and Experiment for Analyte Transport in the First Vacuum Stage of the Inductively Coupled Plasma Mass Spectrometer (opens in a new tab) Download PDF for Comparing Theory and Experiment for Analyte Transport in the First Vacuum Stage of the Inductively Coupled Plasma Mass Spectrometer (opens in a new tab)

  3. Nanogap for wireless fluidics and dielectric manipulations

    … of measurement signals to the size of the analyte. However, adequate transport of the analytes to these small volumes is often not addressed and can greatly limit detection. Diffusion transport, being the state-of-the-art, is not rapid and results in random analyte placement. In this work, …

    umn Repository record for Nanogap for wireless fluidics and dielectric manipulations (opens in a new tab)

  4. Characterization of the Desorption Electrospray Ionization Mechanism Using Microscopic Imaging of the Sample Surface

    … interactions between the DESI spray and test analytes on a glass surface. Microscopic images recorded with millisecond time resolution have provided important insights into the processes governing analyte transport and desorption. These insights are the basis of a rivulet-based model for …

    byu Repository record for Characterization of the Desorption Electrospray Ionization Mechanism Using Microscopic Imaging of the Sample Surface (opens in a new tab) Download PDF for Characterization of the Desorption Electrospray Ionization Mechanism Using Microscopic Imaging of the Sample Surface (opens in a new tab)

  5. Fabrication, Metrology, and Transport Characteristics of Single Polymeric Nanopores in Three-Dimensional Hybrid Microfluidic/nanofluidic Devices

    … volumes, short length scales, small numbers of analyte molecules, and new physical phenomena involved. To this end, robust and reproducible methods were developed to fabricate hybrid microfluidic/nanofluidic systems where single, high aspect ratio polymer nanopores (100 nm < d < 500 nm) provide …

    uiuc Repository record for Fabrication, Metrology, and Transport Characteristics of Single Polymeric Nanopores in Three-Dimensional Hybrid Microfluidic/nanofluidic Devices (opens in a new tab)

  6. Chemically sensitive polymer-mediated nanoporous alumina SAW sensors for the detection of vapor-phase analytes

    … design of composite ultrathin vapor-phase analyte gates, and preparation of selectively permeable, polymeric films that mediate analyte transport. Nanoporous alumina SAW devices were fabricated from planar Al SAW devices using an anodization process that yields a high-surface-area …

    tamu Repository record for Chemically sensitive polymer-mediated nanoporous alumina SAW sensors for the detection of vapor-phase analytes (opens in a new tab)

  7. Ion Transmission in the first vacuum stage of an Inductively Coupled Plasma Mass Spectrometer

    … of atomic species to identify factors affecting analyte transport through the sampling orifice of the vacuum interface. Several non-idealities in the performance of the interface were found. (1) Operating conditions and sample compositions can negatively affect the efficiency with which ions are …

    byu Repository record for Ion Transmission in the first vacuum stage of an Inductively Coupled Plasma Mass Spectrometer (opens in a new tab) Download PDF for Ion Transmission in the first vacuum stage of an Inductively Coupled Plasma Mass Spectrometer (opens in a new tab)

  8. Methods for the Detection of Biological Analytes on Dendritic Surface-Enhanced Raman Scattering (SERS) Substrates

    … and inconsistent results, stemming from low analyte concentration at SERS-active sites and irregular formation of “hotspots,” essential for signal enhancement. This doctoral research aims to develop a direct, sensitive SERS-based approach for detecting biological targets, such as proteins and …

    queens Repository record for Methods for the Detection of Biological Analytes on Dendritic Surface-Enhanced Raman Scattering (SERS) Substrates (opens in a new tab)

  9. The effects of organic gases on atomic spectrometric signals in the ICP

    … high temperature promotes transitions of the analyte and the argon support gas making spectral interference a problem. To alleviate this problem in AFS, it was necessary to look higher in the plasma tail, now the entrainment of oxygen and the formation of metal oxides was thought to be …

    vt Repository record for The effects of organic gases on atomic spectrometric signals in the ICP (opens in a new tab)

  10. Ion Transport Behaviors Upstream and Downstream from the Sampling Cone of an Inductively Coupled Plasma Mass Spectrometer

    … interferences, partly arise from changes in the analyte transmission through the interfacial region between the ICP and mass spectrometer with changes in sample matrix. Better understanding of the transmission behaviors of analyte through the sampling and skimmer cones will provide the insights …

    byu Repository record for Ion Transport Behaviors Upstream and Downstream from the Sampling Cone of an Inductively Coupled Plasma Mass Spectrometer (opens in a new tab) Download PDF for Ion Transport Behaviors Upstream and Downstream from the Sampling Cone of an Inductively Coupled Plasma Mass Spectrometer (opens in a new tab)

  11. Advanced Applications of Raman Spectroscopy for Environmental Analyses

    … or separation protocol to extract the analyte from its matrix. Raman spectroscopy is unique in its ability to detect organic or inorganic, airborne or waterborne, and embedded or adsorbed analytes within environmental systems. This ability comes from the inherent abilities of the Raman …

    vt Repository record for Advanced Applications of Raman Spectroscopy for Environmental Analyses (opens in a new tab)

  12. Optofluidic plasmonic onchip nanosensor array for biodetection

    … the sensor performance is limited by inefficient analyte transport. Suspended plasmonic nanohole array (PNA) offers an opportunity to overcome these limitations. A collinear excitation/collection coupling scheme combined with the small footprint of PNA provides unique platform for multiplexing and …

    bu Repository record for Optofluidic plasmonic onchip nanosensor array for biodetection (opens in a new tab)

  13. Active transport and concentration of analytes in microfluidic paper based analytical devices using ion concentration polarization

    … after becoming fully wet. In this work, active transport and concentration of analytes in fully wet paper-based assays is demonstrated by leveraging ion concentration polarization (ICP). The efficacy of ICP-inducing µPADs is demonstrated through transporting and concentrating dye, fluorescein …

    uoit Repository record for Active transport and concentration of analytes in microfluidic paper based analytical devices using ion concentration polarization (opens in a new tab)

  14. Frequency Locked Optical Whispering Evanescent Resonator: Fundamentals and Applications

    … levels. An accurate analysis of the analyte delivery to sensor is important to optimize system performance and data analysis. We visualized analyte transport to a toroidal resonator through the color transition of bromothymol blue and combined this with finite element simulation data …

    arizona-thes Repository record for Frequency Locked Optical Whispering Evanescent Resonator: Fundamentals and Applications (opens in a new tab)

  15. Bridging lab and field: capillary microfluidics for rapid, low-cost, citizen-based pollution monitoring

    … paper-based analytical devices, including slow transport, reliance on precise volume handling, and limited sensitivity. A hollow capillary-driven architecture was first introduced to enable rapid analyte transport and homogeneous signal generation, allowing for the detection of heavy metals such …

    colostate Repository record for Bridging lab and field: capillary microfluidics for rapid, low-cost, citizen-based pollution monitoring (opens in a new tab)

  16. Optofluidic nanostructures for transport, concentration and sensing

    … thesis presents optofluidic nanostructures for analyte transport, concentration and sensing. This work was part of a larger collaborative project between the BC Cancer Agency and the departments of Chemistry, Electrical and Mechanical Engineering at the University of Victoria. In this work, …

    uvic Repository record for Optofluidic nanostructures for transport, concentration and sensing (opens in a new tab)

  17. Localized programmable gas phase electrodeposition yielding functional nanostructured materials and molecular arrays

    … probability considering the diffusion based analyte transport commonly used. Specifically, we applied the discovered localized programmable electrodynamic precipitation concept to collect, spot, and detect airborne species in an active-matrix array-like fashion. The method is tested using …

    umn Repository record for Localized programmable gas phase electrodeposition yielding functional nanostructured materials and molecular arrays (opens in a new tab)